1、 16-BIT Interface Kit 12799A HEWLETT $ PACKARD IC /- IRELAY REGISTER 1 1 I plug-in Capability - FOR USE WITH THE HP 2570A COUPLERICONTROLLER c I r Independent Controls - 16 individual closures Power-On tnitialization -Predetermines initial state of all relays individually Floating Contact Closures -
2、 Permit switching of diverse voltages. Avoids ground loops. Programming Flexibility -. Relays may be set from 2570A control board, teleprinter keyboard, or from punched paper tape. I I WWW.HPARCHIVE.COM -* RadioFans.CN 收音机爱 好者资料库 APPLICATION The 16-BIT RELAY REGISTER, Interface Kit 12799A, provides
3、16 programmable contact closures for control of external devices such as power supplies, solenoids, electrically activated control valves, or instruments requiring control voltage outside of the normal logic ranges. The contact closures may be subdivided in any combination for controlling one or sev
4、eral devices. The voltages switched through the relay contacts can differ from each other and from the 2570A ground by as much as 100 volts peak. Contacts can be connected in series, parallel, or series-parallel, with or without diode isolation. DIVERSE OUTPUT CAPABILITY FOR YOUR SYSTEM Because of t
5、he general purpose nature of the Relay Register Card, the commands provide the flexibility to permit con- trolling external devices (such as controllers) that can return an output to the card, and controlling external devices that need not or cannot return an output to the card (such as a power supp
6、ly). Commands Commands are programmed at the main control card of the 2570A, or given by enabling interfaced devices, such as tele- printer, punched tape readkr, etc. I Reset contacts, expect response signal N Reset contacts, no response signal expected Choice Of Lock-Out Delays A plug-in jumper est
7、ablishes one of two conditions on the Relay Register Card by determining the proper timing for suspending the main control program, if necessary, to pre- vent any further commands to the relays until the require- ments of the system are met. The combination of Commands and the complementary Lockout
8、Delays results in four different response modes. /1 OPE RAT1 0 N Power-On Preset The relay settings at power-on condition are determined in- dividually open (position “0”) or closed (position “1”) by 16 jumpers. This fixed preset condition is also established when the 2570A control system is command
9、ed to normalize, as in reset or start. Relays retain their setting until other- wise commanded. When an I or N command is issued to the Relay Register Card, the relays will set according to the new instructions. All the relays are commanded whether or not a relay setting is to be changed. Settling t
10、ime for each relay is one milli- second. Three milliseconds after the last relay has been set, an output command is issued by the card. PROGRAMMING F LEX1 Bl LlTY Jumper Selectable Programming Control Relays can be set in two groups of eight relays (Two-Word Program), or in four groups of four relay
11、s (Four-Word Program) Two-Word Program Two cycles of 5-millisecond duration each, are required to set all relays. In this method, ASCII codes for , , I , Null, cannot be used. If the few restricted codes are not required in the program, the advantage is rapidity of setting relays and a minimum numbe
12、r of program instructions. Four-Word Program Four cycles of 5-millisecond duration each, are required to set all relays. In this method there are no restrictions on ASCII code utilization and the register can be programmed from any interfaced device capable of generating ASCII signals, such as a tel