1、OPERATING NOTE HIGH FREQUENCY PROBE 11096A HEWLETT PACKARD RadioFans.CN 收音机爱 好者资料库 Page 2 Model J J096A Table 1. Model I I 096A Specifications VOLTAGE RANGE: 0.25 V to 30 V. RESPONSE: Responds to peak value of input. Calibrated to read rms value of a sine wave input. AC TO DC TRANSFER ACCURACY: *Loa
2、ded with 10 megohms 10%. JOO kHz JOO MHz 500 MHz + 1 o C to + 30 C 0.5 dB 1.2 dB 3 dB at 10 kHz and 700 MHz. INPUT IMPEDANCE: 4 megohms shunted by 3 pF max. The High Frequency Adapter adds I pF to the 3 pF specifications. MAXIMUM INPUT: 30 volts rms AC, 200 volts DC. CABLE CONNECTION: Shielded dual
3、banana plug. Fits all standard 3/4 inch dual banana connectors. CABLE LENGTH: 4 ft. (12 J. 9 cm) minimum. WEIGHT: 3-1/2 oz net. ACCESSORIES SUPPLIED: Ground Lead Straight Tip Hook Tip High Frequency Adapter ACCESSORIES AVAILABLE: 11063A 50 Ohm Tee l 1536A 50 Ohm Tee 10218A BNC Adapter 10219A Type 87
4、4 Adapter I 0220A Microdot Adapter *The AC to DC Transfer Accuracy specification is with the I 1096A probe operating into a de voltmeter with input resistance of 10 MS110%. 1. DESCRIPTION. 2. The -hp-Model I 1096A High Frequency Probe converts a de voltmeter into a high frequency ac voltmeter. The p
5、robe is used f1;or ac voltage measurements of 0.25 volts to 30 volts over a fequency range of I 00 kHz to 500 MHz. 111e accuracy of measurement is 0.5 dB 100 kHz to 100 MHz and 1.2 dB to 500 MHz over a temperature range of + I o C to + 30 C. Additional specifications for the I I 096 A Probe are list
6、ed in Table 1. TI1e front cover shows the J l096A Probe with two compatible de voltmeters. Compatible de voltmeters are described in the following paragraph. 3. COMPATIBLE DC VOLTMETERS. 4. The -hp- I 1096A High Frequency Probe operates into any de voltmeter with an input resistance of IO megohms 10
7、%. Directly compatible Hewlett-Packard voltmeters are listed below. The shjelded dual-banana plug on the probe permits direct connection to voltmeter input. -hp- Model 427 A Voltmeter. -hp-Model 3440A Digital Voltmeter with any plug in. -hp- Model 3439A Digital Voltmeter with any plug in. -hp- Model
8、 3430A Digital Voltmeter. 5. OPERATION. 6. To extend the use of the -hp- Model l 1096A Probe three probe-tip accessories are supplied. The Straight Tip or Hook Tip with the ground lead can be used for measurements up to 100 MHz. For measurements above I 00 MHz the High Frequency Adapter permits the
9、probe to be used with a 50 Ohm Tee. a BNC Adapter or other available accessories illustrated in Figure 1. 7. For proper operation the 11096A Probe must be connected to a de voltmeter with 10 fl!D 10% input resistance. The Probe may be used directly with any one of the voltmeters listed under Paragra
10、ph 4. NOTE To use the Probe with 100 IS1 de voltmeter. connect a 11 MS1 shunt resistor across the voltmeter input before attaching the Probe. 8. Since the l l096A Probe converts the ac input to a positive de voltage equivalent to the rms value of a sine wave, set the de voltmeter for a + VDC reading
11、. Connect shielded dual banana plug to voltmeter de input with the GND Plug connected to the common input termjnal. Attach the desired probe tip to the probe body. and connect probe to circuit under test. NOTE The ground lead is required with Straight Tip or Hook Tip. The High Frequency Adapter does
12、 not require the ground lead when used with one of the accessories shown in Figure I . 9. USE 0 F TIPS. 10. The Hook Tip or Straight Tip can be used for measurements up to I 00 MHz. Above I 00 fllHz use the High Frequency Adapter with one of the accessories shown in Figure I. ( RadioFans.CN 收音机爱 好者资
13、料库 ) ) Model 11096A ACCESSORIES AVAILABLE A 10220A MICRODOT ADAPTER 10218A BNC ADAPTER _, 10219A TYPE 874 ADAPTER 908A 50 OHM LOAD Page 3 I l Figure l . 1 l 096A Probe Accessories 11. MAXIMUM INPUT. J 2. The maximum input voltage with any probe tip is 30 volts rrns ac. or 200 volts de. An ac signal
14、superimposed on a de level up to 200 volts may be measured if desired. WHEN MEASURING AN AC VOLT AGE SUPERIMPOSED ON A DC LEVEL, DO NOT CHANGE THE DC LEVEL BY MORE THAN 200 VOLTS WITH THE PROBE CONNECTED TO THE CIRCUIT U DER T EST ; OTHERWISE A VOLTAGE TRASIENT WILL DA.t1AGE THE DIODES WITHIN THE PR
15、OBE. 13. COMPATIBLE DC VOLTMETERS. 14. hp Model 427A. 15. With the 11096A Probe attached to -hp Model 427A Voltmeter the upper end of the 427 A fre4uency range is extended from l MHz to 500 MHz. Voltage levels from 0.25 volts to 30 volts can be measured with.in the specified accuracy of.the probe pl
16、us the de accuracy of the 427 A Voltmeter. 16. hp Model 3440A or 3439A. 17. With the I J096A Probe attached to the input of the -hp- Model 3440A, or 3439A, the magnitude of the ac signal being measured is displayed directly on the front panel digital display as a+ de voltage. When using the Probe wi
17、th the 3440A or 3439A Digital Voltmeter any one of the available plug-in units may be used (-hp Model 344 I A thru 3446A). With the 3443A and 3444A Plug-in Units a 100 microvolt resolution is available on the 1000 mV range. RadioFans.CN 收音机爱 好者资料库 Page4 18. -hp-Model 3430A. 19. When using the Probe
18、with the -hp- Model 3430A Four Digit Digital Voltmeter, a 60% overranging is available on all usable ranges. and a 1 mV resolution is available on the 1000 mV range. The magnitude of the ac signal being measured is displayed directly on the front panel digital display as a + de voltage. 20. THEORY O
19、F OPERATION. 21. The 11096A High Frequency Probe is a peak detector with a voltage divider. The probe converts the ac input signal into a positive de voltage equal to the rms value of the input. The schematic for the 11096A Probe is shown in Figure 2. 22. The 11096A Probe includes a de blocking capa
20、citor Cl, detection diode CR!, resistive divider RI , R3, CR2, R2. and Rin of the de voltmeter. Capacitor Cl charges through diode CRI during negative cycle of the input to produce a positive de voltage at junction of CR I and RI. This positive voltage is equal to the negative peak value below the d
21、e level of the input signal. The resistive voltage divider consisting of RI and R3 in series with CR2, R2 and I 0 MS1 in put resistance of the de voltmeter divides the peak voltage down to an rms value. A JO MS1 input resistance. Rin is required to provide the proper division ratio. 23. At low volta
22、ge levels the non-linearity of the detector diode characteristic curve is compensated by diode CR2. On the linear portion of the detector diode characteristic curve the division ratio of the voltage divider, (Rl , R3. CR2, R2 and Rin) remains constant, and results in 0.707 of the peak at the junctio
23、n of R3 and CR2. On the non-linear portion of the diode curve. low voltage levels. diode CR2 compensates for non-linearity of CRJ by proportionally changing the division ratio of the divider. 24. Resistor R3 * is selected to calibrate the division ratio of the voltage divider. R3 * value range is SO
24、 kS1 to I 00 Hl. Refer to Paragraph 43 for selection of R3*. The value of R3* must result in an accuracy of 0% to+ 3% with an input of 3 volts at I MHz at room temperature. 25. MAINTENANCE. 26. PERFORMANCE CHECKS 27. The following Performance Checks verify proper operation of the 11096A High Frequen