1、I 52 3D R-3A MODELS 523CR/DR ELECTRONIC COUNTERS SERIALS BELOW 826 TRIGGER UNIT MODIFICATION This easily accomplished modification to your Model 523CR/DR Electronic Counter, serial below 826, will better mOasurement reliability, particularly on Phase measurements. Operation of the Trigger Units is i
2、mproved by changing one tube in each Trigger Unit, Replacing the type 6922 used for Amplifier, V601, with a type 7308 will result in lower noise and less drift of sensitivity (triggering point) in the Trigger Units. The modification consists of changing three tubes and their chassis markings, Adjust
3、ment of your counter is required as outlined under “Adjustment Procedure”. COMPONENTS REQUIRED FOR MODIFICATION Quantity Description StockNo. 3 Tube, electron: 7308, for V601 . . . . . . , I . . . 1932-0032 W MODIFICATION PROCEDURE CAUTION Do not remove V601 from any trigger unit while the instrumen
4、t is turned on. Heater voltage to these tubes is regulated and, if one tube is removed, excessive voltage will be applied to the others, 1. Disconnect power. Remove top and bottom plates from instrument. 2. Replace V601 (Type 6922) in each trigger unit with a Type 7308 tube ( Stock No. 1932-0032). 3