HP-130B-BR-Manual 电路图.pdf
《HP-130B-BR-Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-130B-BR-Manual 电路图.pdf(67页珍藏版)》请在收音机爱好者资料库上搜索。
1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 OPERATING AND SERVICE MANUAL MODEL 13OB/BR SERIALS PREFIXED: 201 OSCILLOSCOPE Copyright HEWLETT-PACKARD COMPANY 1959
2、1501 PAGE MILL ROAD, PAL0 ALTO, CALIFORNIA, U. S. A. ) 00013-3 Printed: JAN 1862 RadioFans.CN 收音机爱 好者资料库 Model 130B TABLE OF CONTENTS Table of Contents List of Illustrations ) Section Page I GENERAL DESCRIPTION . 1-1 1 . 1 . General . . . . . . . . . . . . . . . 1 . 1 1.2 . Damage in Transit . 1-1 1
3、.3 . Power Line Voltages . . . . . . . 1 . 1 1.4 . Power Cord . . . . . . . . . . . . 1-1 1.5 . Installation of Rack Mount . 1-1 1.6 . Cathode Ray Tube Warranty . 1-2 I1 OPERATINGINSTRUCTIONS . 2-1 2.1 . Controls and Terminals . . . . . . 2-1 2.2 . Rear-Access Terminals . 2-1 2.3 . Warm-up Drift . 2
4、-1 2.4 . AC or DC Coupling . . . . . . . . 2-2 2.5 . Balanced Inputs . 2-2 2.6 . Operating Procedures . . . . . . . 2-2 111 THEORY OF OPERATION . . . . . . . . 3-1 3- 1 . General Content . . . . . . . . . . 3- 1 3.2 . Over-All Operation . . . . . . . . 3-1 3.3 . Vertical Amplification Channel . . 3-
5、1 3.4 . Horizontal Amplification Channel . 3-2 3.5 . Sweep Generator . . . . . . . . . 3-2 3.6 . Low Voltage Power Supply . . . . 3-3 Section Page 111 THEORY OF OPERATION (contd) 3.7 . High Voltage Power Supply . . . . 3-4 3.8 . Calibrator . . . . . . . . . . . . . 3-4 IV MAINTENANCE . . . . . . . .
6、 . . . . . 4- 1 . Introduction . . . . . . . . . . . . 4.2 . Simple Check Procedure . . . . . 4.3 . Removing the Cabinet . . . . . . . 4.4 . Isolating Troubles to Major Sections . 4.5 . Connecting for 230Volt Operation . 4.6 . Tube Replacement . . . . . . . . 4.7 . Condensed Test and Adjustment Proc
7、edures . . . . . . . . . . 4.8 . Adjustment Procedure . 4.9 . Turn On . 4- 10 . Power Supplies . 4.11 . ReplacingandAdjustingthe CRT . . 4.12 . Checking and Adjusting the Calibrator . . . . . . . . . . . 4.13 . Adjusting the Vertical Amplifier . 4- 14 . Adjusting the Horizontal Amplifier 4.15 . Phas
8、e Shift Adjust . 4.16 . Adjusting Preset . . . . . . . . . 4.16 . Adjusting the Sawtooth Generator and Sweep Amplifier . 4-1 4-1 4-1 4-3 4-3 4-3 4-4 4-5 4-9 4-9 4-9 4-11 4-13 4-13 4-15 4-15 4-17 4-17 LIST OF ILLUSTRATIONS 1 Number Page 1.1 . Model 130B/BR Oscilloscope . . . . . 1-0 1 . 2 . 1 . 2 1.3
9、 . Model 130BR Installation . . . . . . . . 1-3 / Cathode Ray Tube Warranty . . . . . . 2.1 . 2.2 . 2.3 . 2.4 . 2.5 . 2.6 . 2.7 . 2.8 . 2.9 . Operating Controls and Terminals . . . Vertical Balance Adjustment . 2-3 Horizontal Balance Adjustment . . . . 2-4 Internal Synchronization . . . . . . . 2-5
10、External Synchronization . . . . . 2-6 External Horizontal Input . 2-7 AC Coupling Balanced Input . External Intensity Modulation . . . . . 2-10 2-0 Internal Sweep. Internal Sweep. 2-8 Connection to CRT Deflection Plates . . 2-9 Number Page 4.5 . Vertical Amplifier Adjustment Locations . 4-12 4.6 .
11、Horizontal Amplifier Adjustment Locations . 4-14 4.7 . SweepGenerator Adjustment Locations . 4-16 4.8 . Vertical Amplifier. Voltage Resistance Diagram . . . . . 4-20 4.9 . Vertical Amplifier. Schematic . . . . . 4-21 4.10 . Horizontal Amplifier. Voltage Resistance Diagram . . . . . 4-22 4.11 . Horiz
12、ontal Amplifier. Schematic . 4-23 4.12 . Sweep Generator. Voltage Resistance Diagram . . . . . 4-24 4.13 . Sweep Generator. Schematic . 4-25 4.14 . Sweep Time/CM Switch . . . . . . . . . 4-26 Voltage Resistance Diagram . . . . . 4-27 4.2 . Line Voltage Connection . . . . . . . 4-4 Schematic Diagram
13、4-29 2.10 . Aligning ScopeTracewithGraticule . . 2-11 4.15 . Power Supply Regulator. 4.1 . Location Diagram for Major Circuits . 4-2 4.17 . Filament and Primary Detail. 4.3 . Power Supply Location Diagram . . . . 4-8 4.18 . Sweep Time/CM Switch. 4.4 . Servicing Etched Circuit Boards . . . . 3 . 1 .
14、130B Diagram . . . . . . 3-0 4.16 . Power Supply. Schematic . . . . . . . . 4-28 . . . . . . . . . . Assembly Diagram . . . . . . . . . . 4-30 LIST OF TABLES 4.1 . Condensed Test and Adjustment 4.3 . Regulated Power SupplyTolerances . . 4-9 Procedures . 4-6 5.1 . Reference Designator . . . . . . . .
15、 . . 5-2 4.2 . Tube Replacement Chart . . . . . . . . 4-7 5.2 . Table of Replaceable Parts . . . . . . . 5-13 00013-2 iii i / RadioFans.CN 收音机爱 好者资料库 Model 130B SPECIFICATIONS SWEEP Sweep Range: 0.2 ,usec/cm to at least 12.5 sec/cm. 21 cal- ibrated sweeps, accurate within fs%, in a 1-2-5-10 sequence
16、, 1 ,usec/cm to 5 sec/cm. Vernier permits continuous adjustment of sweep time between calibrated steps and extends slowest sweep time to at least 12.5 sec/cm. Magnifier: X5 Magnifier may be used on all ranges and expands fastest sweep to 0.2 pec/cm. Ac- curacy within 10%. Phase Shift: Within f lo re
17、lative phase shift at frequencies up to 50 kc between vertical and horizontal amp- lifiers with verniers in cal. Stability: 1 mv/hr after warmup. Bandwidth DC Coupling: dc to 300 kc. AC Coupling: 2 cps to 300 kc. Specified bandwidth is independent of sensitivity setting. Balanced Input: On 1,2,5,10,
18、20 and 50 mv/cm ranges. Cabinet Mount input impedance: megohms shunted with approximately 25 pf. Rack Mount input shunt capacity. Disconnecting the wires at the Synchronization: Internally from line voltage or from signals causing 1/2 centimeter or more vertical deflec- or more. Trigger Point: tion.
19、 from 5 Peakmto-peak impedance 2 megohms, approximately 125 pf Continuously adjustable from approximately -30 to +30 volts on either positive or negative slope of external synchronizing signal, or from any point of the vertical signal presented on the screen. Preset Triggering: Switch position on sw
20、eep mode control selects optimum setting for automatic triggering. INPUT AMPLIFIERS Vertical and horizontal amulifier s have same characteristics. Sensitivity: 1 mv/cm to at least 125 v/cm. 15 calibrated ranges, accurate within *5%, in a 1-2-5-10 sequence, 1 mv/cm to 50 v/cm. Vernier per- mits conti
21、nuous adjustment between ranges and decreases sensitivity of 50 v/cm range to at least 125 volts/cm. Input voltage rating 600 volts dc or rms. front panel which connect to the rear terminals reduces the input capacity to approximately 25 pf. Common Signal Rejection: (Balanced input only): Rejection
22、at least 40 db. not exceed 1.5 volts. Common signal must Single Ended Input: Cabinet Mount input impedance: 1 megohm shunted with approximately 50 pf. Rack Mount input impedance: 1 megohm, approximately 200 pf shunt capacity. Disconnecting the wires at the front panel connecting to the rear terminal
23、s reduces the input capacity to approximately 50 pf. 300 millivolts peak-to-peak f 2%, 300 cycles squarewave applied to vertical or horizontal amplifiers by CAL position of input attenuators. Internal Calibrator: iv 00013-2 Model 130B SPECIFICATIONS (CONTD.) GENERAL External Graticule (Standard): Ed
24、ge lighted graticule with controlled illumina- tion, 10 cm x 10 cm, marked in centimeter squares with 2 mm subdivisions, on major hori- zontal and vertical axes. Internal Graticule (Optional): 10 cm x 10 cm, major horizontal. CRT Plates: Direct connection to deflection plates via ter- minals on rear
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-130B-BR-Manual 电路图 HP 130 BR Manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。