1、 . DCS 3kW Series DC Power Supplies Operation Manual This manual covers models: DCS8-350 DCS55-55 DCS12-250 DCS60-50 DCS20-150 DCS80-37 DCS40-75 DCS150-20 Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR (1-800-733-5427) Tel: (858) 450-0085 Fax
2、: (858) 458-0267 Email: 2002 by Elgar Electronics Corporation This document contains information proprietary to Elgar Electronics Corporation. The information contained herein is not to be duplicated or transferred in any manner without prior written permission from Elgar Electronics Corporation. Se
3、ptember 13, 2002 Document No. 1065787 Rev V RadioFans.CN 收音机爱 好者资料库 SAFETY NOTICE Before applying power to the system, verify that the DCS Series unit is configured properly for the users particular application. WARNING! HAZARDOUS VOLTAGES IN EXCESS OF 280 VRMS, 600V PEAK MAY BE PRESENT WHEN COVERS
4、ARE REMOVED. QUALIFIED PERSONNEL MUST USE EXTREME CAUTION WHEN SERVICING THIS EQUIPMENT. CIRCUIT BOARDS, TEST POINTS, AND OUTPUT VOLTAGES MAY BE FLOATING ABOVE (BELOW) CHASSIS GROUND. Installation and service must be performed by qualified personnel who are aware of dealing with attendant hazards. T
5、his includes such simple tasks as fuse verification. Ensure that the AC power line ground is connected properly to the DCS Series unit input connector or chassis. Similarly, other power ground lines including those to application and maintenance equipment must be grounded properly for both personnel
6、 and equipment safety. Always ensure that facility AC input power is de-energized prior to connecting or disconnecting the input/output power cables. During normal operation, the operator does not have access to hazardous voltages within the chassis. However, depending on the users application confi
7、guration, HIGH VOLTAGES HAZARDOUS TO HUMAN SAFETY may be generated normally on the output terminals. Ensure that the output power lines are labeled properly as to the safety hazards and that any inadvertent contact with hazardous voltages is eliminated. To guard against risk of electrical shock duri
8、ng open cover checks, do not touch any portion of the electrical circuits. Even when the power if off, capacitors can retain an electrical charge. Use safety glasses during open cover checks to avoid personal injury by any sudden failure of a component. Due to filtering, the unit has high leakage cu
9、rrent to the chassis. Therefore, it is essential to operate this unit with a safety ground. Some circuits are live even with the front panel switch turned off. Service, fuse verification, and connection of wiring to the chassis must be accomplished at least five minutes after power has been removed
10、via external means; all circuits and/or terminals to be touched must be safety grounded to the chassis. After the unit has been operating for some time, the metal near the rear of the unit may be hot enough to cause injury. Let the unit cool before handling. Qualified service personnel need to be aw
11、are that some heat sinks are not at ground, but at high potential. These operating instructions form an integral part of the equipment and must be available to the operating personnel at all times. All the safety instructions and advice notes are to be followed. Neither Elgar Electronics Corporation
12、, San Diego, California, USA, nor any of the subsidiary sales organizations can accept any responsibility for personal, material or consequential injury, loss or damage that results from improper use of the equipment and accessories. i RadioFans.CN 收音机爱 好者资料库 SAFETY SYMBOLS CAUTION Risk of Electrica
13、l Shock CAUTION Refer to Accompanying Documents Off (Supply) Standby (Supply) On (Supply) Protective Conductor Terminal Fuse Direct Current (DC) Alternating ThreePhase Earth (Ground) Terminal Chassis Ground Current (AC) Alternating Current ii RadioFans.CN 收音机爱 好者资料库 ELGAR FIVEYEAR WARRANTY Elgar Ele
14、ctronics Corporation (hereinafter referred to as Elgar) warrants its products to be free from defects in material and workmanship. This warranty is effective for one year from the date of shipment of the product to the original purchaser. Liability of Elgar under this warranty shall exist provided t
15、hat: the Buyer exposes the product to normal use and service and provides normal maintenance on the product; Elgar is promptly notified of defects by the Buyer and that notification occurs within the warranty period; the Buyer receives a Return Material Authorization (RMA) number from Elgars Repair
16、Department prior to the return of the product to Elgar for repair, phone 800-73-ELGAR (800-733-5427), ext. 2295; the Buyer returns the defective product in the original, or equivalent, shipping container; if, upon examination of such product by Elgar it is disclosed that, in fact, a defect in materi
17、als and/or workmanship does exist, that the defect in the product was not caused by improper conditions, misuse, or negligence; and, that Elgar QA seal and nameplates have not been altered or removed and the equipment has not been repaired or modified by anyone other than Elgar authorized personnel.
18、 This warranty is exclusive and in lieu of all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness of the product to a particular purpose. Elgar, its agents, or representatives shall in no circumstance be liable for any direct, ind