HP-35601A_ops_svc_35601_90001 电路图.pdf
《HP-35601A_ops_svc_35601_90001 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-35601A_ops_svc_35601_90001 电路图.pdf(132页珍藏版)》请在收音机爱好者资料库上搜索。
1、O P E R A T I N G I C E 1 %s con adapter with the grounding wire (green) firmly connected to an electrical ground (safety ground) at the power outlet. The power jack and mating plug of the power cable meet International Electrotechnical Commission (IEC) safety standards 00 NOT OPERATE IN AN EXPLOSIV
2、E ATMOSPHERE e l e c l n t h e P r 6 S e n C e f fa m m a b , e g a s e s o r f u m e s- i o n of any electrical instrument in such an environment constitutes a definite safety hazard. KEEP AWAY FROM LIVE CIRCUITS Operating personnel must not remove instrument covers. Component replacement and inter
3、nal adjustments must be made by qualified maintenance personnel. Do not replace components 3 COnneC*ed T U n d e r c e r t conditions, dangerous voltages may exist eTen w l SZZZSfiZZved-To avo,d injuries a,ways disconnect power and discha * DO NOT SERVICE OR ADJUST ALONE srssn T*ztadius,ment u n i e
4、 s s a n o , h e r p e r s o n c a p a w e * DO NOT SURSTITUTE PARTS OR MODIFY INSTRUMENT Because of the danger of introducing additional hazards, do not install substitute parts or per form any unauthorized modification to the instrument. Return the instrument to a Hewlett- Packard Sales and Servic
5、e Office for service and repair to ensure that safety featuL ae mat- DANGEROUS PROCEDURE WARNINGS Warnings, such as the example below, precede potentially dangerous procedures throuahout this manual. Instructions contained in the warnings must be followed C e d U r e S t n r o u 9 h o u t WARNING |
6、Dangerous voltages, capable of causing death, are present in this instrument Use ex treme caution when handling, testing, and adjusting. A SAFETY SYMBOLS General Definitions of Safety Symbols Used On Equipment or In Manuals. A h -r O R (-i rb OR Instruction manual symbol: the product will be marked
7、with this symbol when it is necessary for the user to refer to the instruction manual in order to protect against damage to the instrument. Indicates dangerous voltage (terminals fed from the interior by voltage exceeding 1000 volts must be so marked). Protective conductor terminal. For protection a
8、gainst electrical shock in case of a fault. Used with field wiring terminals to in dicate the terminal which must be connected to ground before operating equipment. Low-noise or noiseless, clean ground (earth) terminal. Used for a signal common, as well as providing protection against electrical sho
9、ck in case of a fault. A terminal marked with this symbol must be connected to ground in the manner described in the installation (operating) manual, and before operating the equipment. Frame or chassis terminal. A connection to the frame (chassis) of 1 the equipment which normally includes all expo
10、sed metal struc tures. Alternating current (power line). Direct current (power line). Alternating or direct current (power line). : k The WARNING sign denotes a hazard. It calls attention to a pro- WARNING I cedure, practice, condition or the like, which, if not correctly per- formed or adhered to,
11、could result in injury or death to personnel. CAUTION N O T E : The CAUTION sign denotes a hazard. It calls attention to an operating procedure, practice, condition or the like, which,if not correctly performed or adhered to, could result in damage to or destruction of part or all of the product. Th
12、e NOTE sign denotes important information. It calls attention to procedure, practice, condition or the like, which is essential to highlight. Model 35601A General Information SECTION I GENERAL INFORMATION 1.1 INTRODUCTION This Operating and Service Manual contains information for the installation, o
13、peration, testing, adjustments, and service of the Hewlett Packard Model 35601A Spectrum Analyzer Interface. Figure 1-1 shows the 35601A installed in an -hp- 3047A Spectrum Analyzer System. This manual is part of the system library for the -hp-3047A. The part numbers for both the printed manual and
14、the manual on microfiche are listed on the title page of this manual. Additional copies of this manual, in either form, are available through your nearest Hewlett-Packard Sales/Service office (a list of these are in the back of this manual). This section contains the specifications, general descript
15、ion, safety considerations, and recommended test equipment for the -hp-35601A Spectrum Analyzer Interface. Figure 1-1. The -hp- 35601A Spectrum Analyzer Interface Installed in the -hp- 3047A 1-1 General Information Model 35601A 12. DESCRIPTION The -hp- 35601A is the Spectrum Analyzer Interface for t
16、he -hp-3047A Spectrum Analyzer System. This instrument is not available by itself or as an accessory; it has been designed ex clusively for the -hp- 3047A System. The -hp- 35601A provides the necessary interfacing of the spectrum analyzers in all three operating modes of the -hp- 3047A. 1-3. SPECIFI
17、CATIONS The -hp- 35601A has no specifications of its own. The -hp- 3047A Spectrum Analyzer System has specifications for the entire system as well as for the individual spectrum analyzers, however there are no specifications that apply to the Spectrum Analyzer Interface alone. 1-4. SAFETY CONSIDERAT
18、IONS The Spectrum Analyzer Interface is a Safety Class I instrument and has been designed according to international safety standards. To ensure safe operation and to retain the in strument in a safe condition, the Operating and Service Manual contains information, cau tions and warnings which must
19、be adhered to by the user. NOTE: See the Safety Summary following the Table of Contents of this manual for a discussion of basic safety precautions and safety symbology. The 35601A front panel contains a /V symbol which is an international symbol mean ing *refer to the Operating and Service Manual.
20、The symbol flags important operating in structions located in Section III required to prevent damage to the instrument. To retain the operating condition of the instrument these instructions must be adhered to. 15. RECOMMENDED TEST EQUIPMENT The equipment recommended for the testing and calibration
21、of the -hp- 35601A is shown in Table 1-1. 1-2 Model 35601A General Information Table 1-1. Recommended Test Equipment 1 Equipment 1 Service Tape for -hp-9845B Series 100 I or I Service Tape for -hp- 9845B Series 200 or I Service Disc I for -hp- 9836 I Desktop Computer I Synthesizer I Digital Voltmete
22、r I Oscilloscope Counter Signature Analyzer 5012Termination (2) HP-IB Cable I (5) BNC Cables I 2) BNC T ! Critical Specifications HP-IB Capability HP-IB Controllable 10MHz Reference HP-IB Controllable 75MHz Bandwidth 100MHz Recommended hp Model No. | -hp- part number 35601-10001 -hp- part number 356
23、01-10006 -hp- part number 35601-10011 -hp- 9836 or -hp- 9845B with 1 -hp- 98034A -hp- 3 3 2 5 A o p t 0 0 1 I -hp- 3455A -hp- 180A,1808A. j 1821A or I -hp- 1 740A 1 -hp-5314A -hp- 5004A I -hp- 11048A I -hp- 10833 A 1 -hp- 111 70C 1 -hp- part number 1 1250-0781 I 1-3/1-4 Model 35601A Installation SEC
24、TION II INSTALLATION 2-1. INTRODUCTION This section contains information for the installation of the -hp- Model 35601A into the -hp- 3047A Spectrum Analyzer System. Also included in this section is a discussion of the instru ments power requirements and repackaging information. Since the -hp- 3047A
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-35601A_ops_svc_35601_90001 电路图 HP 35601 A_ops_svc_35601_90001
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf