HP-6101A-Manual 电路图.pdf
《HP-6101A-Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-6101A-Manual 电路图.pdf(53页珍藏版)》请在收音机爱好者资料库上搜索。
1、 HP Archive This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! Thanks to on-line curator: Fons Janssen RadioFans.CN 收音机爱 好者资料库 HEWLETT PACKARD HARRISON DIVISION MODEL 6101A DC POWER SUPPLY HP Part Number 06101-90001 Series Prefixed 6L, 1A, 1E, 11
2、37A and Above (Including Optional Modifications Listed Below) 011, 028 Microfiche No. 06101-90002 OPERATING AND SERVICE MANUAL RadioFans.CN 收音机爱 好者资料库 DC POWER SUPPLY STB SERIES, MODEL 6101A SERIAL NUMBER PREFIX 6L Printed: December 2012 Stock Number: 06101-90001 RadioFans.CN 收音机爱 好者资料库 i TABLE OF C
3、ONTENTS Section Page No. I GENERAL INFORMATION 1-1 1-1. Description 1-1 1-6. Specifications 1-1 1-8. Options 1-1 1-10. Accessories 1-2 1-12. Instrument Identification 1-2 1-15. Ordering Additional Manuals 1-2 II INSTALLATION 2-1 2-1. Initial Inspection 2-1 2-3. Mechanical Check 2-1 2-5. Electrical C
4、heck 2-1 2-7. Installation Data 2-1 2-9. Location 2-1 2-11. Power Requirements 2-1 2-14. 230 Volt Operation 2-1 2-16. Power Cable 2-1 2-19. Rack Mounting 2-2 2-23. Repackaging for Shipment 2-3 III OPERATING INSTRUCTIONS 3-1 3-1. Operating Controls and Indicators 3-1 3-3. Operating Modes 3-1 3-5. Nor
5、mal Operating Mode 3-1 3-7. Constant Voltage 3-1 3-9. Current Limit 3-1 3-11. Connecting Load 3-2 3-14. Operation of Supply Beyond Rated Output 3-2 3-16. Optional Operating Modes 3-2 3-17. Remote Programming, Constant Voltage 3-2 3-24. Remote Resistance Programming, Current Limit 3-3 3-27. Remote Se
6、nsing 3-3 3-32. Series Operation 3-4 3-36. Parallel Operation 3-5 3-38. Auto-Tracking Operation 3-5 3-42. Special Operating Considerations 3-5 3-43. Pulse Loading 3-5 3-45. Output Capacitance 3-6 3-48. Reverse Voltage Loading 3-6 3-50. Reverse Current Loading 3-6 3-52. Multiple Loads 3-6 Section Pag
7、e No. IV PRINCIPLES OF OPERATION 4-1 4-1. Overall Block Diagram Discussion 4-1 4-6. Simplified Schematic 4-2 4-9. Detailed Circuit Analysis 4-3 4-10. Series Regulator 4-3 4-12. Constant Voltage Input Circuit 4-3 4-18. Driver and Error Amplifier 4-3 4-20. Current Limit Circuit 4-3 4-22. Oven Control
8、Circuit 4-3 4-24. Reference Circuit 4-4 4-28. Meter Circuit 4-4 V MAINTENANCE 5-1 5-1. Introduction 5-1 5-3. General Measurement Techniques 5-1 5-8. Test Equipment Required 5-1 5-10. Performance Test 5-3 5-12. Rated Output and Meter Accuracy 5-3 5-15. Load Regulation (Front Terminals) 5-4 5-17. Line
9、 Regulation (Front Terminals) 5-4 5-19. Ripple and Noise 5-4 5-21. Transient Recovery Time 5-5 5-23. Output Impedance 5-5 5-25. Current Limit 5-6 5-27. Troubleshooting 5-6 5-29. Trouble Analysis 5-6 5-37. Repair and Replacement 5-8 5-39. Adjustment and Calibration 5-11 5-41. Meter Zero 5-11 5-43. Vo
10、ltmeter Tracking 5-11 5-45. Ammeter Tracking 5-12 5-47. Constant Voltage Programming 5-12 Current 5-12 VI REPLACEABLE PARTS 6-1 6-1. Introduction 6-1 5-4. Ordering information 6-1 Reference Designators Abbreviations Manufacturers 6-8. Code List of Manufacturers 6-2 Parts List Table 6-5 ii TABLE OF C
11、ONTENTS (CONTINUED) LIST OF TABLES Table Page No. 1-1 Specifications 1-3 5-1 Test Equipment Required 5-2 5-2 Reference Circuit Troubleshooting 5-6 5-3 High Output Voltage Troubleshooting 5-7 5-4 Low Output Voltage Troubleshooting 5-7 Table Page No. 5-5 Common Troubles 5-8 5-6 Selected Semiconductor
12、Characteristics 5-10 5-7 Checks and Adjustments After Replace- ment of Semiconductor Devices 5-10 5-8 Calibration Adjustment Summary 5-11 LIST OF ILLUSTRATIONS Figure Page No. 1-1 DC Power Supply iv 2-1 Input Transformer Primary Connections 2-1 2-2 Rack Mounting, Two Units 2-2 2-3 Rack Mounting, One
13、 Unit 2-2 3-1 Front Panel Controls and Indicators 3-1 3-2 Normal Strapping Pattern 3-1 3-3 Remote Resistance Programming (Constant Voltage) 3-2 3-4 Remote .Voltage Programming (Constant Voltage) 3-2 3-5 Remote Resistance Programming (Current Limit) 3-3 3-6 Remote Sensing 3-3 3-7 Normal Series Connec
14、tions 3-4 3-8 Auto-Series, Two and Three Units 3-4 3-9 Normal Parallel 3-5 Figure Page No. 3-10 Auto-Tracking, Two and Three Units 3-5 4-1 Overall Block Diagram 4-1 4-2 Simplified Schematic 4-2 4-3 Meter Circuit, Simplified Schematic 4-4 5-1 Front Panel Terminal Connections 5-1 5-2 Output Current Me
15、asurement Technique 5-1 5-3 Differential Voltmeter Substitute, Test Setup 5-3 5-4 Output Current, Test Setup 5-3 5-5 Load Regulation, Test Setup 5-4 5-6 Ripple and Noise, Test Setup 5-4 5-7 Transient Recovery Time Test Setup 5-5 5-8 Transient Recovery Time, Waveforms 5-5 5-9 Output Impedance, Test S
16、etup 5-5 5-10 Servicing Printed Wiring Boards 5-9 iii Figure 1-1. Typical STB Power Supply 1-1 SECTION 1 GENERAL INFORMATION 1-1 DESCRIPTION 1-2 The STB Series of power supplies is designed for applications requiring extreme stability, regulation, and insensitivity to ambient temperature variations.
17、 The supply is completely transistorized (all-silicon) and is suitable for either bench or relay rack operation. The accurate programming coefficient allows the supply to be used as a 0.1% calibrator, or as a voltage reference source. It is a Constant Voltage / Current Limiting supply that will furn
18、ish full rated output voltage at the maximum rated output current or can be continuously adjusted throughout the output range. The front panel CURRENT controls can be used to establish the output current limit (overload or short circuit) when the supply is used as a constant voltage source and the V
19、OLTAGE controls can be used to establish the volt- age limit (ceiling) when the supply is used as a constant current source. 1-3 The power supply has both front and rear terminals. Either the positive or negative output terminal may be grounded or the power supply can be operated floating at up to a
20、 maximum of 300 volts off ground. 1-4 A single meter is used to measure either output voltage or output current in one of two ranges. The voltage or current ranges are selected by a METER switch on the front panel. 1-5 The programming terminals located at the rear of the unit allow ease in adapting
21、to the many operational capabilities of the power supply. A brief description of these capabilities is given below: a. Remote Programming The power supply may be programmed from a remote Location by means of an external voltage source or resistance. b. Remote Sensing The degradation in regulation wh
22、ich would occur at the load because of the voltage drop in the load leads can be reduced by using the power supply in the remote sensing mode of operation. c. Series and Auto Series Operation Power Supplies may be used in series when a higher output voltage is required in the voltage mode of operati
23、on or when greater voltage compliance is required in the constant current mode of operation. Auto-Series operation permits one knob control of the total output voltage from a master supply. d. Parallel Operation The power supply may be operated in parallel with a similar unit when greater output cur
24、rent capability is required. e. Auto-Tracking The power supply may be used as a master supply, having control over one (or more) slave supplies that furnish various voltages for a system. 1-6 SPECIFICATIONS 1-7 Detailed Specifications for the power supply are given in Table 1-1. 1-8 OPTIONS 1-9 Opti