HP-11848A_svc_11848_90004_1st_ed 电路图.pdf
《HP-11848A_svc_11848_90004_1st_ed 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-11848A_svc_11848_90004_1st_ed 电路图.pdf(158页珍藏版)》请在收音机爱好者资料库上搜索。
1、S E R V I C E M A N U A L 149A PHASE HOSE INWACE HP 11848A PHASE NOISE INTERFACE :i -fV : . . (f; ESpl HEWLETT l : Z i PACKARD RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 HP11848A PHASE NOISE INTERFACE Service Manual SERIAL NUMBERS This manual applies directly to instruments with serial numbers
2、prefixed: 2621A to 2815A rev.20APR88 For additional important information about serial numbers, refer to INSTRUMENTS COVERED BY THIS MANUAL in Section 1. First Edition Copyright HEWLETT-PACKARD COMPANY 1987 EAST 24001 MISSION AVENUE, TAP C-34, SPOKANE, WASHINGTON, U.S.A. 99220 Service Manual HP Part
3、 11848-90004 Microfiche Service Manual HP Part 11848-90011 Printed in U.S.A.: June 1987 What HEWLETT WIEM PACKARD RadioFans.CN 收音机爱 好者资料库 s no .r OTY. Model 11848A General Information DOCUMENTATION UPDATING An instrument manufactured after the printing of these manuals may have a serial-number prefi
4、x that is not listed on the manual title page. Having a serial-number prefix that is greater than that shown on the title page indicates that the instrument is slightly different from those documented in the manual. In this case, your manual may be provided with updating information to make it as cu
5、rrent as possible. This updating information contains all major change information that applies to instruments beyond the serial-prefix range defined on the title page. Minor changes may not be included but will be covered in subsequent updates you can receive by joining the Documentation Update Ser
6、vice. A Description of the Manual Update Packet A Manual Update packet consists of replacement and addition pages which should be incorporated in your manual to bring it up to date. (An addition page results when new information wont fit on a replacement page.) Signing Up for the Documentation Updat
7、e Service Hewlett-Packard offers a Documentation Update Service that will provide you with further updates and changes as they become available. If you have not received update information that matches the serial number of your instrument, you can receive this information through the Update Service.
8、 If you operate or service instruments with different serial prefixes, we strongly recommend that you join this service immediately to ensure that your manual is kept current. For more information, refer to the Documentation Update Service reply card included in this manual or contact: Hewlett-Packa
9、rd Company Technical Writing Department 24001 E. Mission-TAF C-34 Spokane, WA 99220 (509) 922-4001 Also, if you join the update service, you can indicate whether you choose to be contacted in the future about the quality of the documentation you receive. We are constantly trying to provide the best
10、documentation possible and periodically survey our customers as to their expectations and the usability of the manuals we provide. SAFETY CONSIDERATIONS The Interface is a Safety Class I instrument (that is, provided with a protective earth terminal). Before operation, look over the Phase Noise Inte
11、rface and its related documentation to get familiar with safety markings and instructions. Refer to the Safety Considerations page found at the beginning of this manual for a summary of the safety information. Safety information that applies to the specific task at hand (for example, installation) i
12、s found in this manual. 3 General Information Model 11848A Fuses 50Q Termination Adapters, Type-N to BNC Cable Assembly; BNC to SMB Cables Assemblies; BNC HP 3048A Software Discs Figure I. Accessories Supplied 4 rev.l5DEC87 Model 11848A General Information ACCESSORIES SUPPLIED The accessories suppli
13、ed are pieces of equipment that are shipped with every Interface. The accessories are shown in Figure 1. Line Power Cable. The line power cable may be supplied in several plug configurations, depending on the destination of the original shipment. Refer to Power Cables in the Installation section of
14、this Service manual. Fuses. Rises with a 0.75A rating for 115 Vac (HP part number 2110-0063) and a 0.5A rating for 230 Vac (HP part number 2110-0012) are supplied. One fuse is factory installed according to the voltage available in the country of original destination. Refer to Power Requirements in
15、the Installation of this ; Service manual. HP 3048A Software Discs and Manual Set. The HP 3048A software set and associated manuals are j shipped with the Interface. HP 3048A Software Set (HP part number 11848-61026). HP 11848A Service Manual (HP part number 11848-90004). HP 3048A Operating Manual (
16、HP part number 03048-90001). HP 3048A Reference Manual (HP part number 03048-90002). 50Q Termination. This 50H load is used to terminate the Interfaces Spectrum Analyzer output if no ; RF spectrum analyzer is available (HP part number 1250-0207). Adapters, Type-N to BNC. Three adapters are provided
17、for system operation (HP part number 1250-0780). Cable Assemblies: BNC. Two 30 cm (12 in.) cables are provided for system operation (HP part, number 8120-1838). Noise Floor Test Fixture. This test fixture is used to run performance tests (HP part number , 11848-61032). Cable Assembly: BNC to SMB. Th
18、is cable assembly can be used during troubleshooting (HP part number 08954-60105). 5 General Information Model 11848A RECOMMENDED TEST EQUIPMENT Table 1 lists the test equipment and accessories recommended for use in testing, adjusting, and servicing the Interface. If any of the recommended equipmen
19、t is unavailable, instruments with equivalent minimum specifications may be substituted. Tests for the Interface are performed during the HP 3048A Performance Tests which are available in the HP 3048A Operating Manual in Appendix B, Performance Tests. Table 1. Recommended Test Equipment Instrument T
20、ype Dynamic Signal Analyzer Counter (550 MHz) Function Generator Oscilloscope Power Meter and Sensor Model Number HP 3561A HP 5383A, HP 5386A HP3312A.HP3325A HP 1740A HP 435B or HP 436A with HP8481AorHP8482A Use* ! A,CfP,T P P.T T T * A=Adjustments, C=Functional Checks, P=Performance Tests, Troubles
21、hooting 1 * The HP 3561A is included with the HP 3048A system. OPTIONS AVAILABLE Options are variations on the standard instrument which can be ordered during the purchase. Electrical Options Option 201: Add High Frequency Phase Detector. This option adds a 1.2 to 18 GHz phase detector to the Interf
22、ace. This phase detector extends the range of carrier frequencies that can be demodulated within the Interface without external down conversion by the System. All of the HP 3048A specifications from 1.6 to 18 GHz carrier frequency are valid with this option. Mechanical Options Option 907: Front-Hand
23、le Kit. Front handles are provided when Option 907 is ordered. After shipment, you can order a Front-Handle Kit as HP part number 5061-9689. Option 908: Rack-Flange Kit. Rack flanges are provided for the HP 11848A Phase Noise Interface when Option 908 is ordered. After shipment, you can order a Rack
24、-Flange Kit as HP part number 5061-9677. Option 909: Rack-Flange and Front-Handle Combination Kit. This is not a Front-Handle Kit and a Rack-Flange Kit packaged together; it is a unique part that combines both functions. Combination kits are provided for the HP 11848A Phase Noise Interface when Opti
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-11848A_svc_11848_90004_1st_ed 电路图 HP 11848 A_svc_11848_90004_1st_ed
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf