HP-122A-AR-Manual 电路图.pdf
《HP-122A-AR-Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《HP-122A-AR-Manual 电路图.pdf(60页珍藏版)》请在收音机爱好者资料库上搜索。
1、I . : HP Archive . . This vintage Hewlett Packard document was preserved and distributed by www. Please visit us on the web ! . . On-line curator: Tony Gerbic RadioFans.CN 收音机爱 好者资料库 a d n O P E R A T I N G A N D S E R V I C E M A N U A L DUAL TRACE OSCILLOSCOPE 122AIAR HEWLETT fi PACKARD Pd RadioFa
2、ns.CN 收音机爱 好者资料库 i O P E R A T I N G A N D SERVICE M A N U A L MODEL 122A/AR OSCILLOSCOPE SERIALS PREFIXED: 521- 68 2 10 See Section VI1 for Instruments with other Serial Prefixes. Copyright HEWLETT-PACKARD COMPANYICOLORADO SPRINGS DIVISION 1966 1900 GARDEN OF THE GODS ROAD, COLORADO SPRINGS, COLORA
3、DO, U. S. A 00081 - 4 PRINTED: AU6 1967 RadioFans.CN 收音机爱 好者资料库 Table of Contents Model 122A/AR TABLE OF CONTENTS Section Page I GENERAL INFORMATION - . - . * 1-1 1-1. Description . . . . . . . . . . . . . . 1- 1 1-4. Cathode-Ray Tube . . . . . . . . . . 1-1 1-7. Cathode-Ray Tube Warranty. . 1-2 1-9
4、. Accessory Available . . - - 1-2 1-11. Manual Identification - 1-2 1-13. Scope of Manual - - - . - 1-2 Section Page v MAINTENANCE. . . . . . . . . . . . . . 5-1 5-1. Introduction. . . . . . . . . . . . . 5-1 5-3. Test Equipment. . . . . . . . . . . 5- 1 5-5. Performance Check . . . . . . . . 5- 1 5
5、-7. Vertical Amplifier . . - 5-1 5-14. Horizontal Amplifier. - . - 5-2 5-17. Sweep Generator. - - . - 5-2 5-21. Adjustments . a _ - . 5-4 5-24. Turn On Procedure . 5-4 5-26. Trigger Generator - - 5- 5 5-30. Vertical Amplifiers * - - 5-5 5-44. SweepGenerator . - - * 5 -7 . . . . . . . . . . . . . fl
6、INSTALLATION. - 2-1 2-1. Initial Inspection - - . - . - * 2-1 2-4. Claims and Repackaging 2-1 2-7. Preparation for Use - - . - * 2-1 2-8. Power Requirements - . - * 2-1 . . . . . . . 5-38. Horizontal Amplifier - - - 5-6 2-10. 230-Volt Operation * - - 2-1 VI REPLACEABLE PARTS * * - * * 6- 1 2-12. Thr
7、ee-Conductor Power Cable * 2-1 6-1. Introduction . - - * - * - - * 6- 1 2-14. Ventilation Requirements * * * 2-1 6-4. Ordering Information - - - * - - * * 6- 1 VI1 MANUAL CHANGES AND OPTIONS - * 7-1 2-16. Installation of Amber Filter - - - - 2-1 . . . . . . . . . . . . . . . 1 1 1 OPERATION 3-1 3-1.
8、 Introduction. - - - - - - * 3-1 3-3. Controls and Connectors + - * * 3-1 3-17. Rear PanelConnectors . - - 3-1 IV PRINCIPLES OF OPERATION * * * * 4-1 4-1. Over-All Description - * - - * 4-1 4-2. Generalcontent - * + - * * 4-1 4-4. Vertical Amplification Channels 4-1 4-6. Vertical Presentation Switch
9、 4-2 4-8. Horizontal Amplification Switch 4-2 4-16. High Voltage Power Supply * + . 4-3 4-11. Sweep Generator * - - - 4-2 4-18. Low Voltage Power Supply * 4-3 7-1. Manualchanges . - - - 7-1 7-3. Older Instruments - - - * * - 7-1 7-5. Newer Instruments . - - 7-2 7-7. Options . . . . . . . . . . . . .
10、 . . 7-2 7-9. Option05. 7-2 7-11. Option 06. 7-2 . . . . . . . . . . . . . . . . . . . . . . . . 7-13. Special Instruments - - - - - * * - 7-2 VI11 SCHEMATIC DIAGRAMS * * * - * * 8- 1 8-1. Schematic Diagrams - - . - - 8- 1 8-2. General Notes . . . . . . . . . . 8- 1 8-4. Voltage and Resistance Diagr
11、am Notes 8- 1 8-5. Removing the Chassis - - * * * * - 8- 1 8-7. Tube Replacement - * - - * - * 8- 1 . . . . . . . . . . . . . ii 00081-2 1 i I i i 1 1 ! I ! i i I I 1 , I I i I I I 1 i i i i I i I ,I t ! i I 1 I 1 I ! i I i I i 1 i I I i Model 122A/AR List of Illustrations and Tables LIST OF ILLUSTR
12、ATIONS Number Title Page Number Title Page 1-1. Model 122A/AR Oscilloscope * - - * - - * * 1-0 4-1. Over-all Block Diagram + * * 4-1 3-1. Controls and Connectors - - * * * - - * - 3-2 3-2. Unbalanced Input * * - - * * * * 3-3 3-3. Difference Input - * * - * * * - * * - * 3-4 3-4. Balanced Input - *
13、- * * * * * - - * * * 3-5 3-6. Chopped Operation * * * * * - - - * 3-7 3-7. Alternate Sweep Operation * * * * * * 3-8 3-5. Internal Sweep - Internal Synchronization * 3-6 3-8. Internal Sweep - External Synchronization 3-9 3-9. Vertical Balance Adjustment - * * 3-10 3-10. Vertical Sensitivity Calibra
14、tion - * * * 3-11 3-11. Internal Sweep Magnification * - - - - * * 3-12 3-12. External Horizontal Input * - * - - 3-13 3-13. Intensity Modulation Operation - * * 3-14 3-14. Connection to Deflection Plates * * 3-15 Time. . . . . . . . . . . . . . . . . . . 3- 15. Connecting External Capacitors to Ext
15、end Sweep 3- 16 5- 1. 5-2. 7- 1. 8- 1. 8-2. 8-3. 8-4. 8- 5. 8-6. 8- 7. 8- 8. 8-9. Left-Side Adjustment Location Diagram * Right-Side Adjustment Location Diagram 5-4 - 5-6 Option 05 Graticule Lighting Schematic 7-2 Top View Adjustment Location and Voltage * 8-2 Bottom View Adjustment Location and Vol
16、tage * 8-3 Resistance Diagram - . * - - * . - - 5-4 Vertical Amplifier - - * * - * * * 8-5 Vertical Amplifier Switch Detail * 8-6 Horizontal Amplifier - * - * . * * - 8-7 Sweep Generator * * - - * - - * - * 8-8 Sweep Time - Horiz Sens Switch * - * * . 8-9 High Voltage Power Supply * * - Low Voltage
17、and Filament Supplies * 8-10 Resistance Diagram * - * * * LIST OF TABLES Number Title Page Number Title Page 1-1. Specifications - * * * * - * * * 1-0 5-3. Horizontal Deflection Sensitivity . . . . - 5-2 2-1. Shipping Carton Test Strengths * *2-1 5-5. Low Voltage Power Supply Tolerances . * .5-4 5-4
18、. Sweep Time Accuracy. . . . * . .5-3 3-1. Common Signal Limits * . . * -3-1 6-1. Reference Designators andAbbreviations * 6- 1 5-2. Vertical Deflection Sensitivity - . . 5-1 7-1. Manual Changes . . . . . . . . . . . . 6-2. Replaceable Parts. + . . . . - . . -6-2 7-1 ) 5-1. Required Test Equipment *
19、 . * * * . . 5-0 i 00081-3 iii Section I Figure 1-1 and Table 1-1 Model 122A/AR Figure 1- 1. Model 122A/AR Oscilloscope Table 1- 1. SDecifications SWEEP Sweep Range: 15 calibrated sweeps, from 5 psec/cm to 200 msec/cm, accurate to within 5%, in a 1 , 2, 5 sequence. Vernier permits continuous adjustm
20、ent of sweep time between calibrated steps and extends the 200 msec/cm range to at least 0.5 sec/cm. Sweep Expand: X5 sweep expansion may be used on all ranges and expands fastest sweep to 1 psec/cm. Expansion is about the center of the CRT and expanded sweep accuracy is 5 10%. Synchronization: Auto
21、matic from 50 Hz to 250 kHz; internally from vertical deflection signals causing 1/2 cm or more vertical deflection; from external signals 2. 5 volts peak-to-peak or greater, and from line voltage. Trigger Point: Control overrides automatic and permits thetriggerpoint to be set between -10 and +10 v
22、olts. Turning fully counterclockwise into AUTO restores automatic operation. Posi- tive or negative slope may be selected on the INTernal trigger. Triggering in EXTernal is automatically established on the negative slope. IERTICAL AMPLIFIERS Bandwidth: DC coupled: DC to 200 kHz. AC coupled: 2 Hz to
23、200 kHz. Bandwidth is inde- pendent of calibrated sensitivity setting. Sensitivity: 10 mv/cm to 100 v/cm. 4 calibrated steps accurate within *3%, 10 mv/cm, 100 mv/cm, 1 v/cm, and 10 v/cm. Vernier per- mits continuous adjustment of sensitivity be- tween steps and extends 10 v/cm step to at least 100
24、v/cm. Internal Calibrator: Calibrating signal automatic- ally connected to vertical amplifier for stand- ardizing of gain. accuracv *2%. Input Impedance: 1 megohm, approximately50 pf shunt capacitance. Phase Shift: Vertical and horizontal amplifiers have same phase characteristics within *2 to 100 k
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- HP-122A-AR-Manual 电路图 HP 122 AR Manual
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
RogerMayer_Mongoose.gif
valco_supreme_510-1.jpg
GENERATOR_GWM-5-1.zip
philips An_Sp_2.djvu