1、HP Archive This vintage Hewlett Packard document was preserved and distributed by Pleasevisituson the web! Scanned by on-line curator: Tony Gerbic * For FREE Distribution Only * RadioFans.CN 收音机爱 好者资料库 OPERATING AND SERVICING MANUAL MODEL 7121 POWERSUPPLY Serial511and Above HEWLETT-PACKARDCOMPANY 27
2、5PageMillRoadPaloAlto,California,U.S.A. RadioFans.CN 收音机爱 好者资料库 OPERATINGANDSERVICINGMANUAL FOR MODEL7128 POWERSUPPLY Serial511andAbove Copyright1954byHewlett-PackardCompany Theinformationcontainedinthisbooklet isintendedfortheoperationandmain- tenanceofHewlett-Packardequipmentand isnottobeusedother
3、wiseorreproduced withoutthewrittenconsentoftheHewlett- PackardCompany. HEWLEnPACKARD COMPANY 275PAGE MILL ROAD, PALO ALTO, CALIFORNIA, U.S.A. 7121004.1 RadioFans.CN 收音机爱 好者资料库 TABLEOF CONTENTS FOR MODEL 712B POWERSUPPLY Para.PagePara.Page SECTIONISECTIONIV GENERALDESCRIPTIONMAINTENANCE 1-1General. 1
4、-14-1CoverandBottomPlate 1-2Inspection.1-1Removal4-1 4-2Replacements . .4-1 4-3Adjustments 4-3 SECTIONII4-4LineRegulation Adjustment4-3 2-1ControlsandTerminals.2-14-5AdjustmentofFixed-300 2-2Operation 2-2VoltBiasSupplyOutput Voltage 4-5 4-6AdjustmentOfHVSupply SECTIONIIIOutputVoltage 4-5 4-7SettingV
5、ariableResistor 3-1General. . 3-1R39. 4-5 3-2HighVoltageRegulator4-8SettingtheStopontheH V Circuit. . . . .3-1Control .4-7 3-3BiasSupplyCircuit. 3-3 SECTIONV TABLEOFREPLACEABLEPARTS TABLEOFSPECIFICATIONS OUTPUTVOLTAGES I, DCREGULATEDHIGHVOLTAGE: DCREGULATEDFIXEDBIAS: DCVARIABLEBIAS: ACUNREGULATED: o
6、to+500volts(withoutswitching),200mamaximumload. -300volts,50mamaximumload. oto-150volts,5mamaximumload. 6.3voltsCT,10ampsmaximumload. OUTPUTVOLTAGEREGULATION(forconstantlinevoltage) DCREGULATEDHIGHVOLTAGE: DCREGULATEDFIXEDBIAS: DCVARIABLEBIAS: LINEVOLTAGEREGULATION RIPPLE INTERNALIMPEDANCE DCREGULAT
7、EDHIGHVOLTAGE: RECOVERYTIME METERING CURRENTMETER: VOLTMETER: TERMINALS OVERLOADPROTECTION POWERSUPPLY DIMENSIONS WEIGHT Lessthan50millivoltschangeno-loadtofull-loadatanyoutput voltage. Lessthan50millivoltschangeno-loadtofull-load. Istiedtofixedbias,hencesourceregulationissameasforfixed bias.Interna
8、limpedance0to10,000ohms,dependingonbias controlsetting. RegulatedDCoutputvoltagesvarylessthanl00millivoltsfor linevoltagevariations115volts1O%. Lessthan500microvolts. (Forfrequenciesabove20cps.)Full-load:0.1ohminseries with25microhenriesmaximum.No-load:1ohminserieswith 50microhenriesmaximum. Uponapp
9、licationoffull-load:0.1millisecondmaximum.Upon decreasefromfull-loadto: (a)0ma,0.5millisecondmaximum. (b)25ma,O.1millisecondmaximum. Maximumtransientvoltage,1volt. oto200ma.(highvoltageonly.) Threeranges,0to+500volts,0to+150voltsand0to-150volts. PanelswitchconnectsmetertoDCregulatedhighvoltageorDC v
10、ariablebiasandselectsrange. EitherpositiveornegativeDCregulatedhighvoltageterminalmay begrounded.Positiveterminalsofbothbiassuppliesandnega- tiveterminalsofDCregulatedhighvoltagearecommon. ACline,DCregulatedhighvoltage,DCregulatedfixedbiasand filamentsupplyareseparatelyfused.DCregulatedhighvoltage d
11、ropstoasafevalueifbiasfuseblows. 115volts10%,50to60cps.Approximately120to450watts dependingonloadandlinevoltage. CabinetMount:12-1/2high,20-1/2wide,l4-l/4_deep. RackMount:Panel10-1/2high,19wide,14-1/4deep. CabinetMount:6!1lbs.shippingweightapprox.104lbs. RackMount:62lbs.shippingweightapprox.98lbs. S
12、ECTION I GENERAL DESCRIPTION CAUTION Voltageswhicharedangeroustolife arepresentattheterminalsand withinthisinstrument. 1-1GENERAL TheModel7l2BPowerSupplyisaverystable sourceofcontinuouslyvariabledirectcur- rentforplateandbiascircuits.Italsopro- videsupto10amperes,6.3voltsalternat- ingcurrentforfilam
13、entcircuitsAtwo- rangevoltmeterandamilliammeter(high voltageonly)areprovidedtomeasurethe directcurrentoutput.Thispowersupplyis veryusefulasapowersourceforsmalltrans- mitters,oscillators,complexsystems,cer- taintypesofklystrons,andgenerallabora- toryuse. CAUTION TheACpowershouldbeturnedon foratleast3
14、0secondsbeforeswitch- ingonthehighvoltage.Thisallows theregulatorcircuitstoreachtheir properoperatingpointandavoids excessivevoltageatthehighvoltage terminals. 1-2 INSPECTION Thisinstrumentwasthoroughlytestedand inspectedbeforebeingshippedandisready forusewhenreceived. Aftertheinstrumentisunpacked,i
15、tshould beinspectedfordamagereceivedintransit. Ifanyshippingdamageisfound,followthe procedureoutlinedintheClaimforDamage inShipmentpageatthebackofthisinstruc- tionmanual. 1-1 SECTION II OPERATING INSTRUCTIONS 2-1CONTROLS AND TERMINALS ACPOWER Thistoggleswitchcontrolsthepowersup- pliedtotheinstrument
16、fromthepowerline. WhentheswitchisintheONpositionthe redindicatorlampabovetheswitchwill glow. LINE4AMP Thefuseholder,locatedonthecontrolpanel, containsa 4amperecartridgefuseforthe protectionofthewholeinstrument.The fusemaybereplacedbyturningthefuse- holdercap,removingtheoldfuse,andin- sertinganewfuse
17、.Replacementfusesfor thisinstrumentmustbeoftheSlo-Blo typeasspecifiedintheReplaceableParts List. -300V1/16AMP Thefuseholder,locatedonthecontrolpanel, containsa1/16amperecartridgefusefor theprotectionofthe-300voltfixedbias supply.Thefusemaybereplacedbyturn- ingthefuseholdercap,removingtheold fuse,and
18、insertinganewfuse. NOTE Ifthisfuseblows,thepositive high-voltageregulatorcircuit willdroptheHVvoltagelevelto lessthan100volts,thusprotect- ingexternalequipmentorcir- cuitsagainstthepossibilityof damageduetolossofbias.When theopenfuseisreplaced,allcir- cuitsrestoretonormal. +HV1/2AMP Thefuseholder,lo
19、catedonthecontrolpanel, containsa.5amperecartridgefuseforthe protectionofthehighvoltagedecircuit. Thefusemaybereplacedbyturningthe fuseholdercap,removingtheoldfuse,and insertinganewfuse. 2-1 CAUTION Ifthisfuseblows,immediately turnofftheACPOWERswitch, andthenreplacethefuse.Con- tinuedoperationofthei
20、nstrument withthe+HV1/2AMPfuseopen willdamagethescreengridsof theseriesregulatortubes(V3, V4,V5,V6). HIGHVOLTAGE Thistoggleswitchturnsthehighvoltage directcurrentoffandon.Theswitchalso controlstheredindicatorlightaboveiton thecontrolpanel.Whentheswitchison, theindicatorlampglowsasawarningthat thehig
21、hvoltageisturnedon. 6.3VAC,10AMP Thetwofuseholders,locatedonthecontrol panel,eachcontaina 15amperecartridge fuseforprotectionofthe6.3voltACfila- mentsupplycircuit.Eachfusemaybere- placedbyturningitsfuseholdercap,re- movingtheoldfuse,andinsertinganew fuse.Replacementfusesmustbeofthe Slo-Blotypeasspec
22、ifiedintheReplace- ablePartsList. 6.3VAC10AMPCT Thesebindingpostsareterminalsforthe unregulatedACfilamentsupply. 6.3VAC10AMP Thesearetheterminalsforthe6.3volt unregulatedalternatingcurrent. CT Thisbindingpostistheterminalforthe centertapofthesecondarywindingfrom whichtheunregulatedACistaken. -300V50
23、MA5 !vIAGND Thesebindingpostsareterminalsforthe biassupplyoutputandchassisground. -300V50MA Outputterminalforthefixed-300Vregu- latedvoltagesupply. 5MA Outputterminalforthevariable(0-150 volt)regulatedbiasvoltagesupply. GND Terminalformakingconnectiontothe chassis.Anyoneoftheoutputterminals maybecon
24、nectedtothechassisbycon- nectiontoterminalGND. COM+HVGND Thesebindingpostsareterminalsforthe highvoltagesupply,commonconductor, andchassisground. +HV Outputterminalfortheregulated0-500 voltvoltagesupply. COM OutputterminalcommontotheHV,5MA (variablebias),and-300V50MA(fixed bias)circuits GND Terminal