EMT_140_with schematics(A)电路图.pdf
《EMT_140_with schematics(A)电路图.pdf》由会员分享,可在线阅读,更多相关《EMT_140_with schematics(A)电路图.pdf(30页珍藏版)》请在收音机爱好者资料库上搜索。
1、Contents Page Hints for unpacking and transporting 1 Small parts A Preparing the unit for operation A 1 Opening of the unit and removal of the transit protections 3 A 2 Preparatory work on the unit 3 A 3 Mains connections 5 A 4 Earthing 6 A 5 Connecting the signal lines 7 A 6 Fitting and connecting
2、of the accessories for remote 7 A 7 Calibration of Reverberation Time Indication. 8 A 8 Test tape 8 B Electrical tests and adjustments after initial installation B 1 Setting up the amplifier gain without reverberation plate 9 B 2 Adjusting the overall gain via the reverberation plate 9 B 3 Frequency
3、 response measurements 10 C Connecting the reverberation unit into the signal path C 1 Basic principles 11 C 2 Stereo / Mono operation 11 D Practical operating hints D 1 Units without remote control 12 D 2 Units with remote control 12 D 3 Bass cut at the amplifier 13 Technical data EMT 140 FB-TS 14
4、Technical data EMT 162 TS 15 a Free Download from AnalogR RadioFans.CN 收音机爱 好者资料库 Outline size 17 Circuit diagram. EMT 140 FB-TS EMT 162 TS front view 19 EMT 162 TS rear view 20 EMT 162 TS with open lid 21 Circuit diagram EMT 162 TS 22 Adjustments and test points EMT 162 TS 23 Print board EMT 162 TS
5、 24 Frequency responses EMT 162 TS 25 Tolerance field EMT 140 TS 26 Connection diagram for reverberation generation 27 Circuit diagram for multiple control desk arrangements 28 Spare parts 29 Service Instructions 30 EMT 140 Q 33 a Free Download from AnalogR RadioFans.CN 收音机爱 好者资料库 Small parts EMT 14
6、0 TS Reverberation Unit: 1 Hand wheel, complete 1 Plastic disk 2 open-end wrenches 8 Wire Clips 2 Clip guards 2 Plugs T 3084-2 or: 2 Plugs Cannon XLR-12c 2 Plugs Cannon XLR-13c 1 Power cord (US-version) 1 Power plug* 1 Driver magnet, complete EMT 140 F Remote control Motor unit: 1 Fuse 1 A slow-blow
7、 20 mm x 5 mm 0 1 Fuse 1 A slow-blow 1 1/4 x 1/4 1 Plug T 3055 1 Coupling disk (plastic) 1 Screw cap (US-version) EMT 140 B Remote Control Operating Unit: 1 Bulb socket 1 Bulb 24 V/80 mV 1 cap with lens 1 Resistor 2000 ohms 0.25 W 5 % 1 Condenser 0.1/uF 400 V 1 Toggle switch 2 Fuses 0.5 A, 20 mm x 5
8、 mm 1 Screw cap (Europe version) 1 Fuse holder 2 Fuses 0.5 A, 1 1/4 x 1/4 1 Screw cap (US-version) a Free Download from AnalogR RadioFans.CN 收音机爱 好者资料库 Please read Carefully before unpacking Hints for unpacking and transporting: 1. The equipment should only be moved short distances after being unpac
9、ked. 2. Make sure the case is standing the right way up. The arrows must point upwards. 3. The front of the case should be opened first. Remove nails carefully. Do not use crowbars or levers. 4. The sketch on the front of the Reverberation Unit shows how if should be lifted from the base of the pack
10、ing case and moved to its destination. During transport the dial indicating reverberation time must be at the fop. The equipment should only be moved in an upright position. 5. Only when standing at ifs final destination should the Reverberation Unit be made ready for operation. 6. Before opening th
11、e equipment if is essential that the operating instructions are studied carefully. a Free Download from AnalogR A. Preparing the unit for operation The reverberation unit EDIT 140 is a high precision electroacoustic device requiring particular protec tion during transit. Only when the unit has been
12、unpacked and placed in its final location should the pro tecting devices be removed and the unit prepared for operation. A1 OPENING OF THE UNIT AND REMOVAL OF THE SHIPPING PROTECTIONS 1. First unscrew the two side-plates, then the top cover-plate (the two end-plates and the base-plate should be left
13、 on). 2. Untie the two cartons with accessories from the base-plate and remove them. Remove the card board pieces between the reverberation plate and the traverse units. Untie the moving parts of the damp ing plate. When packed for airfreight, the foam rubber strips between steel-plate and damping p
14、late have to be removed. 3. Untie the shielded cables (with Co-ax plug) from the traverse and plug into the amplifier input sockets. Plug colored Co-ax plug into left-hand channel. A2 PREPARATORY WORK ON THE UNIT The various sections should be prepared for operation as follows: 1. The reverberation
15、plate (large steel sheet) It is held in the tubular frame by means of two steel clips on each side - i.e. 8 altogether - (spare steel clips are provided) which are attached to threaded bolts. The reverberation plate can be tensioned in the frame by means of the nuts on these bolts. a Free Download f
16、rom AnalogR Before shipment four of these nuts (see drawing) have been loosened at the factory by exactly a quarter of a turn (900) counter-clockwise. Therefore, the standard practice is to tighten the plate by means of the same screws exactly 90* clockwise. However, this applies only if no stressin
17、g of the steel clips occurred during transport - which may be caused by shocks etc. In this case, more tension is necessary to obtain the original state. In case of doubt we strictly recommend to have the plate more stressed instead of having it too loose. With too high tension most probably the fre
18、quency response will run out of the tolerance field (too low at bass end), but in the same way distortion with low frequencies will be reduced. In order to vary the tension of the plate, proceed as follows: The inner nuts must be held in position (they must not be allowed to turn) while loosening th
19、e outer lock nuts. The inner nut should now be turned. It should be then held in this position while tightening up the lock nut. The only criterion for correct tensioning are the electroacoustic properties (check of overall response see B 3). If a re-tensioning of the steel-plate is neccessary (e.g.
20、 because a spring has been broken during transport) please refer to B 3, Frequency response measurements (T - 2 S). After tensioning, the top cover-plate of the wooden housing should be replaced. 2. The damping plate Its distance from the reverberation plate can be varied by means of the parallel gu
21、ide mechanism (adjustment of reverberation time). The damping plate is adjusted at the factory so as to achieve - with the damping plate turned in - the smallest defined reverberation time (equal to or less than 1 s). The hand wheel, which is supplied separately, is for adjusting the reverberation t
22、ime. It is pushed through the plate with the scale marking on the top of the unit onto the shaft which operates the lever mechanism of the damping plate. Before fixing the hand wheel on this shaft one should ascertain that the pointer is within the scale. a Free Download from AnalogR In units withou
23、t internal remote control the damping plate should be easily movable by turning the hand wheel. With minimum reverberation time the damping plate must not touch the steel plate. This applies to units with remote control as well. 3. The driving system The black enamelled mounting-plate around the mov
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EMT_140_with schematicsA 电路图 schematics
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf