Crown_Power_Base-1,_460CSL_Service_Manual电路图.pdf
《Crown_Power_Base-1,_460CSL_Service_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Crown_Power_Base-1,_460CSL_Service_Manual电路图.pdf(60页珍藏版)》请在收音机爱好者资料库上搜索。
1、Power Base-1 safe with all types of loads, even totally reactive loads. AC Mains: 120VAC at 60 Hz with standard 3 wire grounded 15A connector with single voltage trans- former and fan for North American units; 100VAC, 120VAC, 220VAC, and 240VAC at 50 or 60 Hz when equipped with universal transformer
2、, applicable fan, and other applicable hardware with country specific power cord. Note that at 50 Hz fan speed is reduced. PERFORMANCE Frequency Response: 0.1dB from 20 Hz to 20 kHz at 1 Watt. Phase Response: 10 from 10 Hz to 20 kHz at 1 Watt. Signal to Noise Ratio: Better than 105 dB (A-weighted) b
3、elow max. average power from 20 Hz to 20 kHz. Total Harmonic Distortion (THD): 0.05% from 20 Hz to 1 kHz, increasing linearly to 0.1% at 20 kHz at 170W. I.M. Distortion: 13V per microsecond. Damping Factor: 1000 from 10 Hz to 400 Hz. DC Offset: 10 millivolts. Input Impedance: Nominally 20K ohms bala
4、nced; 10K ohms unbalanced. Output Impedance: 10 milliohms in series with 13V/S. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a 10 kHz square wave to obtain 40 volts peak-to-peak at each output. Observe the slope of the square wave. It should typically mea
5、sure 17 to 25 V/S. Also, the square wave must not include overshoot, ringing, or any type of oscillation. TEST 11: CROSSTALK Spec: 33 mVAC at 20 kHz. Initial Conditions: Controls per standard. Short input of channel not driven. Procedure: 8 ohm load on each channel. Inject a 20 kHz sine wave into th
6、e Channel 1 input and increase output level to 37.4 VAC. Measure less than 33 mVAC at the output of Channel 2. Inject a 20 kHz sine wave into the Channel 2 input and increase output level to 37.4 VAC. Measure less than 33 mVAC at the output of Channel 1. TEST 12: OUTPUT POWER Spec at 8 Ohm Stereo: 2
7、05W at 0.1% THD. Spec at 4 Ohm Stereo: 230W at 0.1% THD. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a 1 kHz sine wave and measure at least 40.5 VAC at the output of each channel. Load each channel to 4 ohms. Inject a 1 kHz sine wave and measure at least
8、 30.3 VAC. All power measurements must be at less than 0.1% THD. TEST 13: REACTIVE LOADS Spec: No oscillations. Safe with all types of loads. Initial Conditions: Controls per standard. Power Base-1 either channel controls limiting in Parallel Mono Mode. Initial Conditions: Controls per standard; rag
9、 or other obstruction blocking fan so that it does not turn. Procedure: Load the amplifier to 2 ohms on each channel. Inject a 60 Hz sine wave and adjust for 15 Vrms at the output. After a few minutes observe a wave form similar to Figure 4. Remove the input signal from both channels and allow the a
10、mplifier to cool for a few minutes. Switch the amplifier to Parallel Mono and remove the load from Channel 1. Inject the signal into Channel 1 and observe that ODEP limiting occurs at the output of both channels. Remove the load from Channel 2, and install the load on Channel 1. Again, observe that
11、both channels limit. Return all amplifier controls to standard initial conditions. Remove the fan obstruction. TEST 15: LF PROTECTION Spec: Amplifier mutes for low frequency. Initial Conditions: Controls per standard. Procedure: No load. Inject a 0.5 Hz 6 volt peak-to-peak square wave into each chan
12、nel and verify that each channel cycles into mute. TEST 16: SIGNAL TO NOISE RATIO Spec: 100 dB (105 dB A-weighted) below rated 8 ohm power. Initial Conditions: Controls per standard. Short inputs. Procedure: Load each channel to 8 ohms. Measure less than 400 V at the output of each channel (or 100 d
13、B from reference of +34.25 dBu). TEST 17: TURN ON TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure: From an off condition, turn on the amplifier and monitor the output noise at the time of turn on. Note: Turn on noise may increase significantly if the am
14、plifier is cycled off and on. TEST 18: TURN OFF TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure: From an on condition, turn off the amplifier and monitor the output noise at the time of turn off. Note: Turn off noise may increase significantly if the am
15、plifier is cycled off and on. TEST 19: INTERMODULATION DISTORTION Spec at 0 dB Output: 0.01%. Spec at 35 dB Output: 0.05%. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a SMPTE standard IM signal (60 Hz and 7 kHz sine wave mixed at 4:1 ratio) at 200 Watts
16、(32.4 VAC). With an IM analyzer measure less than 0.01% IMD. Repeat test at 35 dB (reference 200 Watts or 32.4 VAC) and mea- sure less than 0.05% IMD. TEST 20: CLIPPING Spec: No protective action during test. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a
17、 1 kHz sine wave at each input and drive output 6 dB into clip for 10 seconds. The amplifier should not activate any protective circuits (ODEP, Fault, or LF Protection). POST TESTING After completion of testing, if all tests are satisfactory, the amplifier controls should be returned to the posi- ti
18、ons required by customer. If conditions are unknown or unspecified, factory settings are as follows: Figure 4. ODEP Limiting Wave Form Power Base-1 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Power Base-1 if it is marked with a yellow dot then R30 should b
19、e a 100 Ohm resistor (A10265-10001). Power Base-1 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Q42718-9 Output Module Parts List (P10233-8 Board) Power Base-1 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Power Base
20、-1 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Q42967-2 Output Module Parts List (P10341-9 Board) Power Base-1 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Q43200-7 Output Module Parts List (P10397-1 Board) Power
21、Base-1 full internal fault protection. Balanced phone jack inputs with internal three-position sensitivity switch. Optional XLR or barrier block input connectors are available with the MT-XLR or MT-BB ac- cessories. Ground lift switch is provided to isolate the chassis ground from the phone jack inp
22、ut ground. Efficient heat sinks and self-contained forced air cool- ing system dissipate heat quickly and evenly for extra amplifier protection and greater power output. Three year “No-Fault” full warranty and guaranteed specifications protect your investment. Fig. 1.1 Power Base Front and Back Pane
23、ls CAUTION: THIS COVER IS NECESSARY FOR EFFICIENT COOLING OF THE AMPLIFIER. REMOVE ONLY TO ACCESS GAIN SWITCH. REG. U.S. PAT. OFF. 4,330,809 4,611,180 CAUTION: TURN OFF AMPLIFIER BEFORE CHANGING THIS SWITCH! STEREO BRIDGE MONO PARALLEL MONO BRIDGE-MONO WIRING TURN AMPLIFIER OFF. SET STEREO/MONO SWIT
24、CH TO BRIDGE-MONO. OUTPUT ACROSS RED TERMINALS ONLY. (CH-1 IS POSITIVE.) PARALLEL-MONO WIRING TURN AMPLIFIER OFF. SET STEREO/MONO SWITCH TO PARALLEL-MONO. ADD JUMPER (14 GAGE OR LARGER) ACROSS RED TERMINALS. OUTPUT ACROSS CH-1 TERMINALS ONLY. 1 2 3 4 1 2 3 CH-2CH-1 + + THIS AMPLIFIER IS EQUIPPED WIT