Allen GL4800+Service+Manual+AP61512电路图.pdf
《Allen GL4800+Service+Manual+AP61512电路图.pdf》由会员分享,可在线阅读,更多相关《Allen GL4800+Service+Manual+AP61512电路图.pdf(51页珍藏版)》请在收音机爱好者资料库上搜索。
1、SERVICE INFORMATION SERVICE INFORMATION Publication AP6151 RadioFans.CN 收音机爱 好者资料库 2gl4800_ap6151_1.doc Introduction This publication provides technical information on servicing the Allen & Heath GL4800GL4800. Included are internal layout drawing, block diagram and circuit schematics with board layo
2、uts and spare parts lists. Whilst we believe this information to be reliable we do not assume responsibility for inaccuracies. We also reserve the right to make changes in the interest of further product development. Additional Resources Allen & Heath web site www.allen- Product information Technica
3、l downloads Distribution contacts Company contacts Technical support supportallen- See web for local contact GL4800GL4800 User Guide AP6150 Operating instructions Performance specification GL4800GL4800 AP6152 Fitting instructions SYS-LINK Fitting Instructions GL4800GL4800 AP6285 System Description S
4、YS-LINK Applications Note Cabling Details GL4800GL4800 Service Information Issue status: gl4800_ap6151_1.doc Print date: 01 July 2005 Copyright 2005 Allen & Heath. All rights reserved Kernick Industrial Estate, Penryn, Cornwall, TR10 9LU, UK http:/www.allen- RadioFans.CN 收音机爱 好者资料库 gl4800_ap6151_1.d
5、oc 3 Servicing Precautions General Notes Service personnel: Service work should be carried out by technically qualified service personnel only. Mains power is dangerous and can kill. Do not attempt to work on a linear or switched mode power supply if you are not suitably qualified to do so. Do not a
6、ttempt to repair surface mount circuit assemblies unless you are suitably qualified and have the necessary facilities to do so. Replacement circuit assemblies can be ordered. Service facilities: Ensure a suitably sized work surface is available. Ensure this is clear of dirt, debris and obstructions
7、which may damage the equipment surfaces. Ensure adequate lighting. Use the correct tools for the job and ensure they are in good working order. Ensure all workshop safety requirements are adhered to. Service information: Check that you have all the information you need before starting the service jo
8、b. Refer to the Allen & Heath web site or contact Allen & Heath technical support for details on the latest information. Full technical information can be downloaded from the web site Distributor Zone (password required). Mains power: Connect the equipment to mains power only of the type described i
9、n the user guide and marked on the rear panel. The power source must provide a good ground connection. Ensure you always use an isolation transformer when working on any mains power supply unit. Mains cord and fuse: Use the correct power cord as supplied with the equipment. Do not remove or tamper w
10、ith the ground connection in the power cord. Heed the Important Mains Plug Wiring Instructions printed in the user guide if it is necessary to rewire the mains cord. Always replace the equipment mains fuse with the correct type and rating as described in the user guide and marked on the equipment pa
11、nel. Opening the unit: Switch off and remove the mains power cord before opening the equipment. Ensure all power supply covers and safety shields are in place before applying power with the unit open for diagnostic fault finding. Closing the unit: Before finishing, check the quality and accuracy of
12、the service work carried out. Remove any dirt or debris as this may cause equipment failure in the future. Ensure all assemblies, harnesses and connectors are correctly aligned and plugged in. Ensure that jumper settings and control configurations are correctly set according to the requirements of t
13、he customer. Testing the unit: Before operating the equipment, read and adhere to the Important Safety Instructions printed in the user guide. Test that the service work has been successfully carried out. Shipping the unit: Use adequate packing such as the original packaging or purpose designed flig
14、ht case if you need to ship the unit. To avoid injury to yourself or damage to the equipment take care when lifting, moving or carrying the equipment. Servicing Notes GL4800GL4800 User maintenance: There are several user configurable jumper links inside. These are described in the user guide togethe
15、r with instructions on how to change the default settings. Technology: The GL4800GL4800uses conventional thru-hole and SMT (surface mount) PCB technology. In certain cases it may be better to replace a faulty assembly rather than try to fix it without the appropriate tools and training. The console
16、uses a rack mountable external linear power supply (RPS11). Due to the mains voltages present in the power supply, it should be serviced by suitably qualified personnel only. Operation: To test the console make sure it is connected as described in the user guide. Check that the voltage setting on th
17、e power supply rear panel is correct for the local mains supply. Fault finding: For effective fault diagnosis trace the signal flow through the circuit path. Refer to the system block diagram. Replacement circuit assemblies are available from Allen & Heath. RadioFans.CN 收音机爱 好者资料库 4gl4800_ap6151_1.d
18、oc Contents Log Internal Layout drawing.gl4800_layout_1.pdf Surface and Main Parts .gl4800_parts_1.pdf System Block Diagram. gl4800_blockdiagram_1.pdf Master PCB .gl4800_002-165_master_2.pdf Slave PCB. gl4800_002-167_slave_1.pdf MPU PCB. gl4800_002-198_mpu_2.pdf Mono Input PCB . gl4800_003-410_mono_
19、input_2.1.pdf Stereo Input PCB.gl4800_003-411_stereo_input_3.1.pdf Group PCB (A,B & C) . gl4800_003-412_413_414_group_3.3.pdf Mono PCB. gl4800_003-415_mono_3.2.pdf 8M Connector PCB.gl4800_003-416_8m_conn_2.pdf 4SM Connector PCB .gl4800_003-417_4sm_conn_2.pdf 4MS Connector PCB .gl4800_003-418_4ms_con
20、n_2.pdf 8S Connector PCB .gl4800_003-419_8s_conn_2.pdf Master Connector PCB.gl4800_003-420_master_conn_3.pdf Power Connector PCB . gl4800_003-423_power_conn_b.pdf Mix Amp Sub PCB.gl4800_003-452_mix_amp_sub_1.pdf GL Series Meter PCB.glseries_meters_3.pdf Kernick Industrial Estate, Penryn, Cornwall, E
21、ngland. TR10 9LU +44 (0)8707 556250 +44 (0)8707 556251 2.1 GL4800 MONO INPUT AG262112 PAGE: TITLE: DRG No:ISSUE:SHEET:OF ISSUEBYDATE FILE:C2621_2.1P1.SCH09:49:2316-Jun-2005 ALLEN&HEATH Tel: Fax:PRINTED: ABCDEFGH a b c d e CHK BY 1 2 3 4 5 6 7 8 9 10 11 12 CONN1 FLEX SKT 12 WAY 90 DEG DIR_OUT SEND DI
22、RECT OUT INSERT INSERT RETURN- + 0V LINE IN + - MIC / LINE IN+ - SAFE / PR MUTE_LED MUTE MUTE_LED MUTE SAFE/PR TO INPUT-8 CONNECTOR PCB 5 4 6 S15B 2 1 3 S15A SW2PCOL (SPUN) PP +48V R43 22K R6 6K8 1% R4 6K8 1% MLIN+ MLIN- C14 47/63 C39 47/63 R1 47K R5 47K + - R3 12K 1% R2 12K 1% 2 1 3 S1A SW2PCOL (SP
23、UN) 5 4 6 S1B 2 1 3 S2A SW2PCOL (SPUN) 5 4 6 S2B R8 100K R7 100K C2 47/25 C3 47/25 MIC/LINE PHASE C4 330P/DISK C6 330P/DISK R9 47K R10 47K C5 NF R11 2K2 1% D5 1N4002 D6 1N4002 Q1 2SB737 Q4 2SB737 Q2 BC549 Q3 BC549 R15 47R C37 330/10 16 4 RV1A POT14 10KC X2 R12 4K7 1% R17 4K7 1% +VC+VC INPUT PREAMP R