1、AG500 TEST PROCEDURE18 MAR, 2005 Part 1: Quality Assurance StepQA CheckAction 1MOSFETs Using feeler gauge, check that MOSFETs are flush gainst ceramic substate, and that substrate is flush against heat sink 2Thermal switch Verify that thermal switch termals are tight and that yellow wires do not tou
2、ch heat sink 3KnobsVerify all knob position 4SwitchesVerify all switches function mechanically 5LED lensesVerify all LED lenses are flush with faceplate 6AC jumpers Verify AC jumpers on AG5JK are configured correctly for the target AC voltage Part 2: Adjustments and Functional Test All AG500 AC cord