Allen Xone+VF1+Schematics电路图.pdf
《Allen Xone+VF1+Schematics电路图.pdf》由会员分享,可在线阅读,更多相关《Allen Xone+VF1+Schematics电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、 ALLEN&HEATH WARNING HIGH VOLTAGES Power Supply Unit (PSU) work should only be carried out by qualified personnel. We recommend that you use an approved Allen & Heath service centre for all power supply work. Please contact your local Allen & Heath distributor for more details. http:/www.allen- Radi
2、oFans.CN 收音机爱 好者资料库 SERVICE INFORMATION SERVICE INFORMATION Publication AP6047 RadioFans.CN 收音机爱 好者资料库 2 xonevf-1_ap6047_1.doc Introduction This publication provides technical information on servicing the Allen & Heath XONE VF-1 Analogue Filter unit. Included are internal layout drawings, block diag
3、rams and circuit schematics with board layouts. Whilst we believe this information to be reliable we do not assume responsibility for inaccuracies. We also reserve the right to make changes in the interest of further product development. Additional Resources Allen & Heath web site www.allen- Product
4、 information Technical downloads Distribution contacts Company contacts Technical support supportallen- See web for local contact XONE VF-1 user guide AP5917 Operating instructions Performance specification XONE VF-1 Service Information Issue status: xonevf-1_ap6047_1.doc Print date: 07 December 200
5、4 Copyright 2004 Allen & Heath. All rights reserved Manufactured in the United Kingdom by Allen & Heath Kernick Industrial Estate, Penryn, Cornwall, TR10 9LU, UK http:/www.allen- RadioFans.CN 收音机爱 好者资料库 xonevf-1_ap6047_1.doc 3 Servicing Precautions General Notes Service personnel: Service work shoul
6、d be carried out by technically qualified service personnel only. Mains power is dangerous and can kill. Do not attempt to work on a linear or switched mode power supply if you are not suitably qualified to do so. Do not attempt to repair surface mount circuit assemblies unless you are suitably qual
7、ified and have the necessary facilities to do so. Replacement circuit assemblies can be ordered. Service facilities: Ensure a suitably sized work surface is available. Ensure this is clear of dirt, debris and obstructions which may damage the equipment surfaces. Ensure adequate lighting. Use the cor
8、rect tools for the job and ensure they are in good working order. Ensure all workshop safety requirements are adhered to. Service information: Check that you have all the information you need before starting the service job. Refer to the Allen & Heath web site or contact Allen & Heath technical supp
9、ort for details on the latest information. Full technical information can be downloaded from the web site Distributor Zone (password required). Mains power: Connect the equipment to mains power only of the type described in the user guide and marked on the rear panel. The power source must provide a
10、 good ground connection. Ensure you always use an isolation transformer when working on any mains power supply unit. Mains cord and fuse: Use the correct power cord as supplied with the equipment. Do not remove or tamper with the ground connection in the power cord. Heed the Important Mains Plug Wir
11、ing Instructions printed in the user guide if it is necessary to rewire the mains cord. Always replace the equipment mains fuse with the correct type and rating as described in the user guide and marked on the equipment panel. Opening the unit: Switch off and remove the mains power cord before openi
12、ng the equipment. Ensure all power supply covers and safety shields are in place before applying power with the unit open for diagnostic fault finding. Closing the unit: Before finishing, check the quality and accuracy of the service work carried out. Remove any dirt or debris as this may cause equi
13、pment failure in the future. Ensure all assemblies, harnesses and connectors are correctly aligned and plugged in. Ensure that jumper settings and control configurations are correctly set according to the requirements of the customer. Testing the unit: Before operating the equipment, read and adhere
14、 to the Important Safety Instructions printed in the user guide. Test that the service work has been successfully carried out. Shipping the unit: Use adequate packing such as the original packaging or purpose designed flight case if you need to ship the unit. To avoid injury to yourself or damage to
15、 the equipment take care when lifting, moving or carrying the equipment. Servicing Notes XONE VF-1 User maintenance: There are no user serviceable parts inside. Refer any service work to competent technical personnel only. Technology: The XONE VF-1 uses SMT (surface mount) PCB technology. In certain
16、 cases it may be better to replace a faulty assembly rather than try to fix it without the appropriate tools and training. The power supply is a built-in universal mains input, switched mode circuit which should be serviced by suitably qualified personnel only. Operation: The XONE VF-1 is an analogu
17、e filter unit. To ensure optimum performance and reliability it should be connected and operated as described in the user guide. Fault finding: Refer to the system block diagram and circuit drawings to follow through the signal path during fault diagnosis. Replace suspected faulty components only wi
18、th those specified by Allen & Heath. The use of lower grade alternatives may degrade the performance. 4 xonevf-1_ap6047_1.doc Contents Log Internal Layout Drawing.xonevf-1_layout_1.pdf Surface and Main Parts.xonevf-1_parts_1.pdf System Block Diagram . xonevf-1_blockdiagram_1.pdf Main PCB Assembly is
19、s.1.xonevf-1_003-358_main_1.pdf Main PCB Assembly iss.4.xonevf-1_003-358_main_4.pdf RIAA Option PCB.xonevf-1_003-360_riaa_a.pdf RIAA Option Fitting Instructions .xonevf-1_riaa_fitting_1.pdf xone_vf-1_layout_1.doc Sheet 1 of 1 VR5 Product.XONE:VF-1/120 .XONE:VF-1/220 .XONE:VF-1/240 .XONE:VF-1R/120 .X
20、ONE:VF-1R/220 .XONE:VF-1R/240 Main Assembly. 003-357 PCB Assembly . 003-358 Pack Assembly. 003-359 RIAA Option PCB Assy . 003-360 Valve ECC82 .AE5139 LN 123 GG 3213 2112 3 C117 SW10 P1 BR1 C113C114C115 CN2CN3CN4 CN5 CN6 CN7CN8CN9 CN10 CN12 AB 1 1 CN13CN14 CN15 CN16 F1 L1 LD1LD2LD3 LD4LD5LD6 LD7 LD8
21、LD9 LD10 LD11 LD12 LD13 LD14 LP1LP2LP3 LP4 NTC1 R207 SW2 SW3 SW4 SW5 SW6 SW7 SW8 SW9 TX1 VR1VR2 VR3 VR4VR6 CN17 PIC SKT SW1 CN1 WARNING HIGH VOLTAGE! FH1FH2 CN1 VALVE ECC82 AE5139 PCB ASSY 003-358 RIAA OPTION 003-360 Kernick Industrial Estate, Penryn, Cornwall, England. TR10 9LU +44 (0)8707 556250 +
22、44 (0)8707 556251 1 XONE VF-1 MAIN PCB C587715 PAGE: TITLE: DRG No:ISSUE:SHEET:OF ISSUEBYDATE FILE:AG5877_1 SHEET 1.Sch14:45:174-Nov-2004 ALLEN&HEATH Tel: Fax:PRINTED: ABCDEFGH a b c d e CHK BY R4 10K 1% R33 20K 1% C2 15P C1 15P 5 6 7 U1B TL072D T R CN2 R32 20K 1% W R A CN1A R1 10K 1% R13 10K 1% R35
23、 20K 1% C4 15P C3 15P 3 2 1 U1A TL072D T R CN3 R34 20K 1% R10 10K 1% W R B CN1B OUT_LEFT OUT_RIGHT C30 100N C33 100N PRE_OUT_L PRE_OUT_R L_OUT_- L_OUT_+ R75 100K 1% R76 100K 1% C47 100N C48 100N C12 47/25 C13 47/25 3 2 1 U3A TL072D C43 100P_S C46 100P_S C45 100P_S C44 100P_S 5 6 7 U3B TL072D R15 10K