1、Aug, 1997ME-30 TABLE OF CONTENTSPage SPECIFICATIONS2 LOCATION OF CONTROLS 3 EXPLODED VIEW5 PARTS LIST 6 LOADING FACTORY PRESET DATA7 TEST MODE 7 12 IC DATA13 BLOCK DIAGRAM13 CIRCUIT DIAGRAM from MODE 1 to MODE 6. Use whichever appropriate for your situation. CAUTION ! The user data cannot be saved t
2、o a sequencer via MIDI. Inform the user of this fact upon receiving a service request. The test program will stop upon detecting a failure component or circuit, and may not proceed to the next step. After taking a corrective action, restart the test program from the beginning. Connection to OUTPUTs:
3、 Unless otherwise specifically instructed, channels L and R are independently monitored: first connect the plug from the measuring instrument (oscilloscope or noise meter, whichever appropriate) into OUTPUT R, next, replace the instrument plug with a blank (open) plug and then connect the instrument
4、 to OUTPUT L. Note that the channel R signal is connected to the OUTPUT L socket through the switch on the OUTPUT R socket. To obtain pure L channel signal, the R socket switch must be turned off. IDENTIFYING VERSION NUMBER LOADING FACTORY PRESET DATA TEST MODE 8 ME-30 Aug, 1997 Test Item 1. Panel L
5、CD .LED Check 2. SW Check 3. DSP Check 4. Output Frequency Response Check 5. Output Mute Circuit Check 6. OD/DS Circuit Check 7. OD/DS Gain Check 8. Input Frequency Response Check 9. AUX Circuit Check 10. Residual Noise Check and Shock Noise Check 11. OD/DS Circuit Noise Check and Shock Noise Check
6、12. NS , Tuner Check 13. EV Pedal Check Equipment Required . Oscillator ( Audio Generator ) . Oscilloscope . Noise Meter . Opened Plug To Enter the Test Mode While pressing the EFFECT ON/OFF Key , PARAMETER ( L ) Key and PARAMETER ( R ) Key simultaneously , turn the power on. All the LCD are turned
7、on. Do the following operation to select the mode. Press PEDAL 1 to start with 1. Panel LCD LED Check . NOTE : As for the following MODE 2 to MODE 6 , each mode starts after DSP check. Press PEDAL 2 to start with 4. Output Frequency Response Check . Press PEDAL 3 to start with 6. DOD/DS Circuit Chec
8、k . Press PEDAL BANK DOWN to start with 8. Input Frequency Response Check . Press PEDAL BANK UP to start with 10. Residual Noise Check and Shock Noise Check . Press MANUAL Key to start with 13. EV Pedal Check . Mode 6 to start DSP check , when return back to the previous step. Exiting test mode Simp
9、ly turn off the ME-30. 9 1. LCD & LED test Press the pedal 1. The LCD starts displaying the test pattern shown in Fig. 1. Verify that the segments are turned on. Press a key and verify that the 7-seg LED and the pedal LEDs are turned on in the order shown in Fig. 2. 2. Switch test Press a key and th
10、e LCD will read SW1. Press the keys in the order shown in Fig. 3 and verify that pressed key is represented on the LCD. The test stops upon detecting a defective key and wont proceed to the next key. Take a corrective action and return to the step 1. When the test is successful, the test program pro
11、ceeds to the step 3. DSP test. 3. DSP test The test program automatically starts the test step 3 - 1. after completion of the step 2. 3 - 1. Initialization When the unit is initialized, the program goes to the step 3 - .2. Otherwise, it displays ERROR 1 and jumps to the step 4. 3 - 2. Internal RAM t
12、est The program writes the test data into and reads out from the internal RAM and then goes to the step 3 - 3. If error, it displays ERROR 2 and jumps to the step 4. 3 - 3. External RAM test The program writes the test data into and reads out from the external RAM and then goes to the step 4. If err
13、or, it displays ERROR 3 and goes to the step 4. 4. Output frequency response test The LCD displays TEST 1. Sine waves of 20 Hz - 1 kHz - 5 kHz - 15 kHz - 20 Hz from DSP are sent to OUTPUT sockets at 0.8 sec. interval. Connect a noise meter to OUTPUT R. Set the meter to FLAT and check the readings ag
14、ainst the table below. Connect a noise meter to OUTPUT L (with the blank plug in R) and check the readings. The difference in readings between R and L must be within 1 dBm. Monitor OUTPUTs R and L and PHONES R and L in that order on the oscilloscope and make sure they are look like the waveforms sho
15、wn in Fig. 4. To go to the step 5, press VALUE + key. 5. Output stage muting test The LCD displays TEST 2. A 1 kHz sine wave from DSP is sent to OUTPUT sockets at 0.5 sec. interval. In the similar way as in the step 4 above, connect the noise meter or scope to OUTPUT R and then L (with the blank plu
16、g in R) and check the readings. The difference in readings between R and L must be within 1 dBm. Monitor OUTPUTs R and L and PHONES R and L in that order on the oscilloscope and make sure they are look like the waveforms shown in Fig. 5. To go to the step 6, press VALUE + key. To return back to the
17、step 4, press VALUE - key. 6. OD and DS circuit test The LCD displays TEST 3. A 200 Hz square wave from DSP is sent to OUTPUTs at 0.8 sec. interval at four different levels. Monitor the outputs by first connecting the scope to OUTPUT R and then L (with the blank plug in R) and make sure that the wav
18、eforms look like the ones shown in Fig. 6. To go to the step 7, press VALUE + key. To return back to the step 5, press VALUE - key. 7. OD and DS gain test The LCD displays TEST 4. A 200 Hz sine wave from DSP is sent to OUTPUTs at an 0.8 sec. interval at four different levels. Monitor the outputs by
19、first connecting the scope to OUTPUT R and then L (with the blank plug in R) and make sure that the waveforms look like the ones shown in Fig. 7. To go to the step 8, press VALUE + key. To return back to the step 6, press VALUE - key. 8. Input frequency response test The LCD displays TEST 5. Apply a
20、 square wave of 200 Hz, 200 mV to INPUTs. Monitor the outputs by first connecting the scope to OUTPUT R and then L (with the blank plug in R) and make sure that the waveform looks like the one shown in Fig. 8. To go to the step 9, press VALUE + key. To return back to the step 7, press VALUE - key. 9
21、. AUX circuit test The LCD displays TEST 6. Apply a square wave of 200 Hz, 200 mV to AUX INP. The input signal is modified into three waveforms which are sent to OUTPUTs at an 0.5 sec. interval. Monitor the outputs by first connecting the scope to OUTPUT R and then L (with the blank plug in R) and m
22、ake sure that the waveforms look like the ones shown in Fig. 9. To go to the step 10, press VALUE + key. To return back to the step 8, press VALUE - key. 10. Residual and shock noises The LCD displays TEST 7. Short-circuit the inputs (e.g. insert a short circuit plug into INPUT and AUX IN). Set the
23、noise meter to JIS-A or IHF and connect it first to OUTPUT R and then L (with the blank plug in R) and make sure that the readings are -88.0 dBm or below. Also verify that difference in noise level between channels is 1 dBm or less. Level -20 dBm 1 dBm -20 dBm 1 dBm -20 dBm 1 dBm -20 dBm 1 dBm Frequ
24、ency 20 Hz 1 kHz 5 kHz 15 kHz Aug, 1997ME-30 10 13 EV pedal test The LCD displays TES*. Swing the volume control foot pedal (EV) and check the values shown on the LCD. For pressing operation, refer to the EV adjustment shown below. If these values are not obtained, go to the FV Adjustment below. To