Crownpb3sm电路图.pdf
《Crownpb3sm电路图.pdf》由会员分享,可在线阅读,更多相关《Crownpb3sm电路图.pdf(27页珍藏版)》请在收音机爱好者资料库上搜索。
1、Power Base-3 the space is considered a character.) The seventh character is usually a hy- phen, though it may be a letter to indicate a revision or special note. The last character is called a check-digit, and is useful to Crown for internal tracking. Crown is in the process of converting to a new p
2、art number system. Length may vary from eight to twelve characters. There is still a letter prefix, then five numbers. These five numbers identify a type of part. The seventh character is a hyphen. Remaining char- acters identify the details of the type of part identified by the first part of the nu
3、mber. STANDARD AND SPECIAL PARTS Many smaller electrical and electronic parts used by Crown are stocked by and available from electronic supply houses. However, some electronic parts that appear to be standard are actually special. A part ordered from Crown will assure an acceptable re- placement. S
4、tructural items such as modules and panels are available from Crown only. ORDERING PARTS When ordering parts, be sure to give the product model, and include a description and part number (CPN/DPN) from the parts listing. Price quotes are available on request. SHIPMENT Shipment will be normally made
5、by UPS or best other method unless you specify otherwise. Shipments are made to and from Elkhart, Indiana USA, only. Estab- lished accounts with Crown will receive shipment freight prepaid and will be billed. All others will receive Crown Parts Department Mailing Address: PO Box 1000 Elkhart, IN USA
6、 46515-1000 Shipping Address: 57620 C.R. 105 Elkhart, IN USA 46517 Phone: (219) 294-8210 or: (219) 294-8211 Toll Free: (800) 342-6939 FAX: (219) 294-8301 Power Base-3 safe with all types of loads, even totally reactive loads. AC Mains: 120VAC at 60 Hz with standard 3 wire grounded 15A connector with
7、 single voltage trans- former and fan for North American units; 100VAC, 120VAC, 220VAC, and 240VAC at 50 or 60 Hz when equipped with universal transformer, applicable fan, and other applicable hardware with country specific power cord. Note that at 50 Hz fan speed is reduced. PERFORMANCE Frequency R
8、esponse: 0.1dB from 20 Hz to 20 kHz at 1 Watt. Phase Response: 10 from 10 Hz to 20 kHz at 1 Watt. Signal to Noise Ratio: A-weighted, better than 105 dB below full rated output. Better than 100 dB below full rated output from 20 Hz to 20 kHz. Total Harmonic Distortion (THD): 0.05% from 20 Hz to 1 kHz
9、, increasing linearly to 0.1% at 20 kHz at 500W. I.M. Distortion: 13V per microsecond. Damping Factor: 1000 from 10 Hz to 400 Hz. DC Offset: 10 millivolts. Input Impedance: Nominally 20K ohms balanced; 10K ohms unbalanced. Output Impedance: 10 milliohms in series with 17V/S. Initial Conditions: Cont
10、rols per standard. Procedure: Load each channel to 8 ohms. Inject a 10 kHz square wave to obtain 65 volts peak-to-peak at each output. Observe the slope of the square wave. It should typically measure 17 to 25 V/S. Also, the square wave must not include overshoot, ringing, or any type of oscillation
11、. TEST 11: CROSSTALK Spec: -60dB at 20 kHz. Initial Conditions: Controls per standard. Terminate input of channel not driven with 600 ohms. Procedure: 8 ohm load on each channel. Inject a 20 kHz sine wave into the Channel 1 input and increase output level to 62 VAC. Measure less than 62 mVAC at the
12、output of Channel 2. Inject a 20 kHz sine wave into the Channel 2 input and increase output level to 62 VAC. Measure less than 62 mVAC at the output of Channel 1. TEST 12: OUTPUT POWER Spec at 8 Ohm Stereo: 540W at 0.1% THD. Spec at 4 Ohm Stereo: 760W at 0.1% THD. International 8 Ohm Stereo:Internat
13、ional 8 Ohm Stereo:International 8 Ohm Stereo:International 8 Ohm Stereo:International 8 Ohm Stereo: 510W at 0.1% THD. International 4 Ohm Stereo:International 4 Ohm Stereo:International 4 Ohm Stereo:International 4 Ohm Stereo:International 4 Ohm Stereo: 680W at 0.1% THD. Initial Conditions: Control
14、s per standard. Procedure: Load each channel to 8 ohms. Inject a 1 kHz sine wave and measure at least 65.7 VAC at the output of each channel. Load each channel to 4 ohms. Inject a 1 kHz sine wave and measure at least 55.1 VAC. All power measurements must be at less than 0.1% THD. TEST 13: REACTIVE L
15、OADS Spec: No oscillations. Safe with all types of loads. Initial Conditions: Controls per standard. Procedure Capacitive: Load each channel to 8 ohms in parallel with 2 F. Inject a 20 kHz sine wave with 55 VAC output for 10 seconds. Procedure Inductive: Load each channel to 8 ohms in parallel with
16、159 Henries. Inject a 1 kHz sine wave with 35.8 VAC output for 10 seconds. Procedure Torture: Load each channel with the primary (red and black leads) of a DC-300A transformer (D 5781-6). Inject a 10 Hz sine wave at sufficient output level to cause 3 to 5 flyback pulses, for 10 seconds. Procedure Sh
17、ort: Inject a 60 Hz sine wave at 5 VAC minimum output. After establishing signal, short the output for 10 seconds. InOut .047 uF 1K Ohm Differenciator Circuit Power Base-3 either channel controls limiting in Parallel Mono Mode. Initial Conditions: Controls per standard; rag or other obstruction bloc
18、king fan so that it does not turn. Procedure: Load the amplifier to 4 ohms on each channel. Inject a 60 Hz sine wave and adjust for 35 Vrms at the output. After a few minutes observe a wave form similar to Figure 4. Remove the input signal from both channels and allow the amplifier to cool for a few
19、 minutes. Switch the amplifier to Parallel Mono and remove the load from Channel 1. Inject the signal into Channel 1 and observe that ODEP limiting occurs at the output of both channels. Remove the load from Channel 2, and install the load on Channel 1. Again, observe that both channels limit. Retur
20、n all amplifier controls to standard initial conditions. Remove the fan obstruction. TEST 15: LF PROTECTION Spec: Amplifier mutes for low frequency. Initial Conditions: Controls per standard. Procedure: No load. Inject a 0.5 Hz 6 volt peak-to-peak square wave, or a 2 Hz 6VAC sine wave into each chan
21、nel and verify that each channel cycles into mute. TEST 16: SIGNAL TO NOISE RATIO Spec: 100 dB below rated 8 ohm power 20 Hz to 20 kHz. 105 dB A-Weighted. Initial Conditions: Controls per standard. Short inputs. Procedure: Load each channel to 8 ohms. Measure less than 648 V at the output of each ch
22、annel (20 Hz- 20 kHz bandpass filter). TEST 17: TURN ON TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure: From an off condition, turn on the amplifier and monitor the output noise at the time of turn on. Note: Turn on noise may increase significantly if
23、the amplifier is cycled off and on. TEST 18: TURN OFF TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure: From an on condition, turn off the amplifier and monitor the output noise at the time of turn off. Note: Turn off noise may increase significantly if
24、the amplifier is cycled off and on. TEST 19: INTERMODULATION DISTORTION Spec at 0 dB Output: 0.01%. Spec at 35 dB Output: 0.05%. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a SMPTE standard IM signal (60 Hz and 7 kHz sine wave mixed at 4:1 ratio) at 495
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Crown pb3sm 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf