1、101969-6 3/01 Models: Com-Tech 210, 410, 810 how- ever, an unlimited number of R.S.V.P. modules can be slaved together to accommodate any system size. The power on/off function is controlled from an IQ-Sys- tem AUX or Control Port or from a simple remote con- tact-closure switch. When under IQ Syste
2、m control, all remote manual-control switches are automatically dis- abled. This provides priority access to the IQ user and prevents accidental turnoff. For manual switch configu- ration, two normally-open momentary switches are re- quired: one switch provides the signal to turn the unit on, while
3、the second switch provides the signal to turn the unit off (see Figure 3.13). 3.3.4 Output Connection WARNING: Output terminals marked with the sym- bol are dangerous when live. External wiring connected to these terminals requires installation by an instructed person, or should make use of prebuilt
4、 wiring and con- nectors. Fig. 3.13 Connecting the RSVP Module Page 22 Com-Tech Power Amplifiers Reference Manual Consider the power handling capacity of your load be- fore connecting it to the amplifier. Crown is not liable for damage incurred at any time due to overpowering. Fus- ing loudspeaker l
5、ines is highly recommended (see Sec- tion 3.3.5). Also, please pay close attention to Section 4.1, Precautions. You should always install loudspeaker cables of suffi- cient gauge (wire thickness) for the length used. The resistance introduced by inadequate output cables will reduce the amplifiers po
6、wer to and motion control of the loudspeakers. The latter problem occurs because the damping factor decreases as the cable resistance increases. This is very important because the amplifiers excellent damping factor can be easily negated by us- ing insufficient cable. Use the nomograph in Figure 3.1
7、4 and the following procedure to find the recommended wire gauge (AWG or American Wire Gauge) for your system. 1. Note the load resistance of the loudspeakers con- nected to each channel of the amplifier. If you are using 70-volt output, be sure to determine the load resis- tance of the step-down tr
8、ansformers (Crowns constant voltage computer can help with this, see Section 8.3). Mark this value on the Load Resistance line of the no- mograph. 2. Select an acceptable damping factor and mark it on the Damping Factor line. Your amplifier can provide an excellent damping factor of 1,000 from 10 to
9、 400 Hz in Stereo mode with an 8-ohm load. In contrast, typical damping factors are 50 or lower. Higher damping fac- tors yield lower distortion and greater motion control over the loudspeakers. A common damping factor for commercial applications is between 50 and 100. Higher damping factors may be
10、desirable for live sound, but long cable lengths often limit the highest damping factor that can be achieved practically. (Un- der these circumstances, Crowns IQ System is often used so amplifiers can be easily monitored and con- trolled when they are located very near the loudspeak- ers.) In record
11、ing studios and home hi-fi, a damping factor of 500 or more is desirable. 3. Draw a line through the two points with a pencil, and continue until it intersects the Source Resistance line. 4. On the 2-Cond. Cable line, mark the length of the cable run. 5. Draw a pencil line from the mark on the Sourc
12、e Resis- tance line through the mark on the 2-Cond. Cable line, and on to intersect the Annealed Copper Wire line. 6. The required wire gauge for the selected wire length and damping factor is the value on the Annealed Cop- per Wire line. Note: Wire size increases as the AWG gets smaller. 40 30 20 1
13、5 10 9 8 7 6 5 4 3 2 1 2 5 10 20 50 100 .04 .06 .1 .2 .4 .6 1 2 4 6 10 20 40 5 10 20 50 1 2 100 200 500 1000 2000 5000 8000 5000 1000 500 100 50 10 5 1 .5 .1 .05 .01 #28 #26 #24 #22 #20 #18 #16 #14 #12 #10 #8 #6 #4 #2 #0 #00 #0000 R LOAD RESISTANCE (ohms) L R R DAMPING FACTOR L S R SOURCE RESISTANCE
14、 (ohms) S 2-COND. CABLE (feet) ANNEALED COPPER WIRE (AWG) (ohms/1000 ft.) Example Shown: R = 8 ohms; R = 0.016 ohms or D.F. = 500; Cable Length = 10 ft.; answer: #8 wire LS 1 0.5 200 500 1,000 2,000 20,000 5,000 10,000 .01 .001 .02 .004 .006 .002 .0004 .0006 .0002 0.6 0.7 0.8 1.5 0.9 Fig. 3.14 Wire
15、Size Nomograph Page 23 Com-Tech Power Amplifiers Reference Manual 7. If the size of the cable exceeds what you want to use, (1) find a way to use shorter cables, like using the IQ System, (2) settle for a lower damping factor, or (3) use more than one cable for each line. Options 1 and 2 will requir
16、e the substitution of new values for cable length or damping factor in the nomograph. For option 3, esti- mate the effective wire gauge by subtracting 3 from the apparent wire gauge every time the number of con- ductors of equal gauge is doubled. So, if #10 wire is too large, two #13 wires can be su
17、bstituted, or four #16 wires can be used for the same effect. SOLVING OUTPUT PROBLEMS High-frequency oscillations can cause your amplifier to prematurely activate its protection circuitry. The ef- fects of this problem are similar to the RF problems de- scribed in Section 3.3.2. To prevent high-freq
18、uency oscillations: 1. Bundle together each pair of loudspeaker conduc- tors when using long cable runs or when different amplifiers use a common cable tray or jacket. (Do NOT bundle wires from different amplifiers.) This reduces the chance of conductors acting like an- tennas to transmit or receive
19、 the high frequencies that can cause oscillation. 2. Avoid using shielded loudspeaker cable. 3. Never tie together input and output grounds. 4. Never tie together the output of different amplifiers. 5. Keep output cables separated from input cables. 6. Install a low-pass filter in series with each i
20、nput (see Section 3.3.2). 7. Install the input wiring according to the instructions in Section 3.3.2. Another problem to avoid is the presence of large infra- sonic currents when primarily inductive loads are used. Examples of inductive loads are 70-volt trans- formers and electrostatic loudspeakers
21、. Inductive loads can appear as a short circuit at low fre- quencies. This can cause the amplifier to produce large low-frequency currents and activate its protection cir- cuitry. Always take the precaution of installing a high- Fig. 3.15 Inductive Load (Transformer) Network 4 ohm, 20 watt Resistor
22、590 to 708 f Capacitor 120 VAC, N.P. + Inductive Load + From Amplifier Output pass filter in series with the amplifiers input when induc- tive loads are used. A three-pole, 18-dB-per-octave fil- ter with a 3 dB frequency of 50 Hz is recommended (some applications may benefit from an even higher 3 dB
23、 frequency). Such a filter is described with infrasonic frequency problems in Section 3.3.2. Another way to protect inductive loads from large low- frequency currents and prevent the amplifier from pre- maturely activating its protective systems is to parallel a 590 to 708 F nonpolarized motor start
24、 capacitor and a 4-ohm, 20-watt resistor in series with the amplifier out- put and the positive (+) transformer lead. This circuit is shown in Figure 3.15. It uses components that are avail- able from most electrical supply stores. 3.3.5 Additional Load Protection Com-Tech amplifiers can generate en