Crown_CP660_Operation_Manual电路图.pdf
《Crown_CP660_Operation_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Crown_CP660_Operation_Manual电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、CP660Operation Manual 2005 by Crown Audio, Inc., 1718 W. Mishawaka Rd., Elkhart, Indiana 46517-9439 U.S.A. Telephone: 574-294-8000 Some models may be exported under the name Amcron Trademark Notice: Crown, Crown Audio, and Amcron are registered trademarks of Crown International. Other trademarks are
2、 the property of their respective owners. Obtaining Other Language Versions: To obtain information in another language about the use of this product, please contact your local Crown Distributor. If you need assistance locating your local distributor, please contact Crown at 574-294-8000. This manual
3、 does not include all of the details of design, production, or variations of the equipment. Nor does it cover every possible situation which may arise during installation, operation or maintenance. The information provided in this manual was deemed accurate as of the publication date. However, updat
4、es to this information may have occurred. To obtain the latest version of this manual, please visit the Crown website at . 125381-6 10/05 RadioFans.CN 收音机爱 好者资料库 CP660 Power Amplifi er Operation Manualpage 2 1) Read these instructions. 2) Keep these instructions. 3) Heed all warnings. 4) Follow all
5、instructions. 5) Do not use this apparatus near water. Do not expose to dripping or splashing. Do not place objects fi lled with liquid on unit. 6) Clean only with a dry cloth. 7) Do not block any ventilation openings. Install in accordance with the manufacturers instruc- tions. 8) Do not install ne
6、ar any heat sources such as radiators, heat registers, stoves, or other appa- ratus that produce heat. 9) Do not defeat the safety purpose of the polar- ized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third ground
7、ing prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet. 10) Protect the power cord from being walked on or pinched, particularly at plugs, convenience receptacles, an
8、d the point where they exit from the apparatus. 11) Only use attachments/accessories specifi ed by the manufacturer. 12) Use only with a cart, stand, bracket, or table specifi ed by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combinat
9、ion to avoid injury from tip-over. 13) Unplug this apparatus during lightning storms or when unused for long periods of time. 14) Refer all servicing to qualifi ed service person- nel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged
10、, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. 15) To reduce the risk of fi re or electric shock, do not expose this apparatus to rain or moisture. Important Safety Instructions
11、MAGNETIC FIELD CAUTION! Do not locate sensitive high-gain equip- ment such as preamplifi ers or tape decks directly above or below the unit. Because this amplifi er has a high power density, it has a strong magnetic fi eld which can induce hum into unshielded devices that are located nearby. The fi
12、eld is strongest just above and below the unit. If an equipment rack is used, we recommend locating the amplifi er(s) in the bottom of the rack and the preamplifi er or other sensitive equipment at the top. The lightning bolt triangle is used to alert the user to the risk of electric shock. The excl
13、amation point triangle is used to alert the user to important operating or maintenance instructions. WATCH FOR THESE SYMBOLS: IMPORTANT The CP660 amplifi er requires Class 2 output wiring. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING
14、 TO QUALIFIED SERVICE PERSONNEL. PRVENIR LE CHOC LECTRIQUE NENLEVEZ PAS LES COUVERCLES. IL NY A PAS DES PARTIES SERVICEABLE LINTRIEUR. TOUS REPARATIONS DOIT ETRE FAIRE PAR PERSONNEL QUALIFI SEULMENT. FCC COMPLIANCE NOTICE This device complies with part 15 of the FCC rules. Operation is subject to th
15、e following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifi cations not expressly approved by the party responsible for complicance cou
16、ld void the users authority to operate the euqipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
17、installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular insta
18、llation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. In
19、crease the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. RadioFans.CN 收音机爱 好者资料库 CP660 Power Amplifi er Operation Manualpage 3
20、 Equipment Type: Commercial Audio Power Amplifi ers Family Name: CP Family Model Names: CP660 EMC Standards: EN 55103-1:1995 Electromagnetic Compatibility - Product Family Standard for Audio, Video, Audio-Visual and Entertainment Lighting Control Apparatus for Professional Use, Part 1: Emissions EN
21、55103-1:1995 Magnetic Field Emissions-Annex A 10 cm and 1 M EN 61000-3-2:1995+A14:2000 Limits for Harmonic Current Emissions (equipment input current 16A per phase) EN 61000-3-3:1995 Limitation of Voltage Fluctuations and Flicker in Low-Voltage Supply Systems Rated Current 16A EN 55022:1992 + A1: 19