Crown_Macro-Tech_5002VZ_Service_Manual电路图.pdf
《Crown_Macro-Tech_5002VZ_Service_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Crown_Macro-Tech_5002VZ_Service_Manual电路图.pdf(140页珍藏版)》请在收音机爱好者资料库上搜索。
1、POWER AMPLIFIER SERVICE MANUAL 130446-1 02-00 Rev. A Macro-Tech 2000 by Crown International, Inc., P.O. Box 1000, Elkhart, Indiana 46515-1000 U.S.A. Telephone: 219-294-8000. Trademark Notice: Grounded Bridge, PIP2 and SmartAmp are trademarks and Amcron, Crown, IOC, IQ System, Macro-Tech, ODEP and VZ
2、 are registered trademarks of Crown International, Inc. Other trademarks are the property of their respective owners. Models: MA-5002VZ Some models may be exported under the name Amcron RadioFans.CN 收音机爱 好者资料库 MA-5002VZ Service Manual II 130446-1 Rev. A 2000 Crown International, Inc. PRVENIR LE CHOC
3、 LECTRIQUE NENLEVEZ PAS LES COUVERTURES. RIEN DES PARTIES UTILES LINTRIEUR. DBRANCHER LA BORNE AVANT DOUVRIR LA MODULE EN ARRIRE. TO PREVENT ELECTRIC SHOCK DO NOT REMOVE TOP OR BOTTOM COVERS. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. DISCONNECT POWER CORD BEFO
4、RE REMOVING REAR INPUT MODULE TO ACCESS GAIN SWITCH. CAUTIONAVIS WARNING TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE! The information furnished in this manual does not include all of the details of design, production, or variations of the equipment. Nor doe
5、s it cover every possible situation which may arise during installation, operation or maintenance. If you need special assistance beyond the scope of this manual, please contact the Crown Technical Support Group. Mail: P.O. Box 1000 Elkhart IN 46515-1000 Shipping: Plant 2 SW 1718 W. Mishawaka Road E
6、lkhart IN 46517 Phone: (800) 342-6939 / (219) 294-8200 FAX: (219) 294-8301 The lightning bolt triangle is used to alert the user to the risk of electric shock. The exclamation point triangle is used to alert the user to important operating or maintenance instructions. RadioFans.CN 收音机爱 好者资料库 III 130
7、446-1 Rev. A MA-5002VZ Service Manual 2000 Crown International, Inc. Revision History Revision NumberDateComments Rev. A02-2000Initial Printing RadioFans.CN 收音机爱 好者资料库 MA-5002VZ Service Manual IV 130446-1 Rev. A 2000 Crown International, Inc. This page intentionally left blank V 130446-1 Rev. A MA-5
8、002VZ Service Manual 2000 Crown International, Inc. Table of Contents 1 Introduction . 1-1 1.1 Introduction .1-1 1.2 The MA “02” Series Amplifiers .1-1 1.3 Scope.1-1 1.4 Warranty.1-1 2 Specifications . 2-1 3 Voltage Conversion. 3-1 4 Circuit Theory . 4-1 4.1 Overview .4-1 4.2 Grounded Bridge Theory
9、.4-1 4.2.1 Grounded Bridge Operation .4-2 4.2.2 Output Stage Circuitry.4-3 4.3 VZ Power Supply.4-4 4.3.1 VZ Supply Operation.4-4 4.3.2 VZ Supply Circuitry .4-5 4.4 ODEP Theory .4-6 4.4.1 ODEP Operation.4-6 4.4.2 ODEP Circuitry .4-7 4.5 Front End Theory.4-8 4.5.1 Balanced Gain Stage .4-8 4.5.2 Variab
10、le Gain Stage .4-8 4.5.3 Error Amp .4-8 4.5.4 Compessor.4-9 4.5.5 Loudspeaker Offset Integration .4-9 4.5.6 Voltage Translator and LVA Stages .4-9 4.5.7 Inverting Stages .4-9 4.6 Protection Systems .4-9 4.6.1 Soft Start.4-9 4.6.2 Over-voltage.4-11 4.6.3 DC/LF .4-11 4.6.4 Commom Mode Output Current.4
11、-12 4.6.5 Output Thermal .4-12 4.6.6 Transformer Thermal .4-12 4.6.7 FET Thermal .4-12 4.6.8 Power Loss.4-13 4.6.9 Fan Control.4-13 4.7 Display .4-13 4.8 Mono Modes .4-13 4.8.1 Bridge Mono.4-13 4.8.2 Parallel Mono.4-14 MA-5002VZ Service Manual VI 130446-1 Rev. A 2000 Crown International, Inc. 5 Main
12、tenance. 5-1 5.1 Cautions and Warnings.5-1 5.2 General Information .5-1 5.3 Troubleshooting .5-1 5.3.1 Pre-AC-Checks .5-1 5.3.2 LED Checks .5-2 5.4 Test Procedures.5-4 5.4.1 Standard Initial Conditions .5-4 5.4.2 Equipment Required .5-4 6 Parts . 6-1 6.1 General Information .6-1 6.2 Ordering and Rec
13、eiving Parts .6-1 6.2.1 Terms .6-1 6.2.2 Shipment .6-1 7 Exploded View Parts . 7 -1 8 Module and Schematic Information. 8 -1 9 Module Parts. 9-1 10 Schematics . 10-1 Table of Contents Introduction 1-1 130446-1 Rev. A MA-5002VZ Service Manual 2000 Crown International, Inc. 1.1 Introduction This manua
14、l contains complete service information on the Crown MA-5002VZ power amplifier. It is designed to be used in conjunction with the Reference Manual; however, some important information is duplicated in this Service Manual in case the Reference Manual is not readily available. NOTE: THE INFORMATION IN
15、 THIS MANUAL IS INTENDED FOR USE BY AN EXPERIENCED TECH- NICIAN ONLY! 1.2 The MA “02” Series Amplifiers The Macro-Tech series is a complete family of ampli- fiers designed for pro sound reinforcement. Macro- Tech amplifiers are designed to provide enormous lev- els of pure, undistorted power in a ru
16、gged low-profile package, utilizing Crowns patented Grounded Bridge output topology. They also employ Crowns patented ODEP protection circuitry, which keeps the amplifier working under extreme conditions that would shut down a lesser amplifier. Crowns new Macro-Tech “02” series amplifiers feature Cr
17、owns enhanced PIP2 (Programmable Input Processor) expansion system. The PIP2 expansion system makes it easy to tailor the amplifier to a specific application. Providing high power amplification from 20 Hz to 20 kHz with minimum distortion, Macro-Tech series amplifiers fea- ture balanced inputs with
18、bridged and parallel mono- phonic capability. The MA-5002VZ includes additional features not found on other Macro-Tech series models including switchable compression, switchable loud- speaker offset integration (LOI), and ILOAD/ILIMIT indi- cation. 1.3 Scope This Service Manual in intended to apply