Crown_Power_Base-2,_800CSL_Service_Manual电路图.pdf
《Crown_Power_Base-2,_800CSL_Service_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Crown_Power_Base-2,_800CSL_Service_Manual电路图.pdf(39页珍藏版)》请在收音机爱好者资料库上搜索。
1、Power Base-2 the space is considered a character.) The seventh character is usually a hy- phen, though it may be a letter to indicate a revision or special note. The last character is called a check-digit, and is useful to Crown for internal tracking. Crown is in the process of converting to a new p
2、art number system. Length may vary from eight to twelve characters. There is still a letter prefix, then five numbers. These five numbers identify a type of part. The seventh character is a hyphen. Remaining char- acters identify the details of the type of part identified by the first part of the nu
3、mber. STANDARD AND SPECIAL PARTS Many smaller electrical and electronic parts used by Crown are stocked by and available from electronic supply houses. However, some electronic parts that appear to be standard are actually special. A part ordered from Crown will assure an acceptable re- placement. S
4、tructural items such as modules and panels are available from Crown only. ORDERING PARTS When ordering parts, be sure to give the product model, and include a description and part number (CPN/DPN) from the parts listing. Price quotes are available on request. SHIPMENT Shipment will be normally made
5、by UPS or best other method unless you specify otherwise. Shipments are made to and from Elkhart, Indiana USA, only. Estab- lished accounts with Crown will receive shipment freight prepaid and will be billed. All others will receive Crown Parts Department Mailing Address: PO Box 1000 Elkhart, IN USA
6、 46515-1000 Shipping Address: 57620 C.R. 105 Elkhart, IN USA 46517 Phone: (219) 294-8210 or: (219) 294-8211 Toll Free: (800) 342-6939 FAX: (219) 294-8301 Power Base-2 safe with all types of loads, even totally reactive loads. AC Mains: 120VAC at 60 Hz with standard 3 wire grounded 15A connector with
7、 single voltage trans- former and fan for North American units; 100VAC, 120VAC, 220VAC, and 240VAC at 50 or 60 Hz when equipped with universal transformer, applicable fan, and other applicable hardware with country specific power cord. Note that at 50 Hz fan speed is reduced. PERFORMANCE Frequency R
8、esponse: 0.1dB from 20 Hz to 20 kHz at 1 Watt. Phase Response: 10 from 10 Hz to 20 kHz at 1 Watt. Signal to Noise Ratio: Better than 105 dB (A-weighted) below max. average power from 20 Hz to 20 kHz. Total Harmonic Distortion (THD): 0.05% from 20 Hz to 1 kHz, increasing linearly to 0.1% at 20 kHz at
9、 170W. I.M. Distortion: 13V per microsecond. Damping Factor: 1000 from 10 Hz to 400 Hz. DC Offset: 10 millivolts. Input Impedance: Nominally 20K ohms balanced; 10K ohms unbalanced. Output Impedance: 10 milliohms in series with 13V/S. Initial Conditions: Controls per standard. Procedure: Load each ch
10、annel to 8 ohms. Inject a 10 kHz square wave to obtain 40 volts peak-to-peak at each output. Observe the slope of the square wave. It should typically measure 17 to 25 V/S. Also, the square wave must not include overshoot, ringing, or any type of oscillation. TEST 11: CROSSTALK Spec: 33 mVAC at 20 k
11、Hz. Initial Conditions: Controls per standard. Short input of channel not driven. Procedure: 8 ohm load on each channel. Inject a 20 kHz sine wave into the Channel 1 input and increase output level to 46.9 VAC. Measure less than 40 mVAC at the output of Channel 2. Inject a 20 kHz sine wave into the
12、Channel 2 input and increase output level to 46.9 VAC. Measure less than 40 mVAC at the output of Channel 1. TEST 12: OUTPUT POWER Spec at 8 Ohm Stereo: 320W at 0.1% THD. Spec at 4 Ohm Stereo: 400W at 0.1% THD. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject
13、 a 1 kHz sine wave and measure at least 50.6 VAC at the output of each channel. Load each channel to 4 ohms. Inject a 1 kHz sine wave and measure at least 40.0 VAC. All power measurements must be at less than 0.1% THD. TEST 13: REACTIVE LOADS Spec: No oscillations. Safe with all types of loads. Init
14、ial Conditions: Controls per standard. Power Base-2 either channel controls limiting in Parallel Mono Mode. Initial Conditions: Controls per standard; rag or other obstruction blocking fan so that it does not turn. Procedure: Load the amplifier to 4 ohms on each channel. Inject a 60 Hz sine wave and
15、 adjust for 35 Vrms at the output. After a few minutes observe a wave form similar to Figure 4. Remove the input signal from both channels and allow the amplifier to cool for a few minutes. Switch the amplifier to Parallel Mono and remove the load from Channel 1. Inject the signal into Channel 1 and
16、 observe that ODEP limiting occurs at the output of both channels. Remove the load from Channel 2, and install the load on Channel 1. Again, observe that both channels limit. Return all amplifier controls to standard initial conditions. Remove the fan obstruction. TEST 15: LF PROTECTION Spec: Amplif
17、ier mutes for low frequency. Initial Conditions: Controls per standard. Procedure: No load. Inject a 0.5 Hz 6 volt peak-to-peak square wave into each channel and verify that each channel cycles into mute. TEST 16: SIGNAL TO NOISE RATIO Spec: 100 dB (105 dB A-weighted) below rated 8 ohm power. Initia
18、l Conditions: Controls per standard. Short inputs. Procedure: Load each channel to 8 ohms. Measure less than 400 V at the output of each channel (or 100 dB from reference of +36.25 dBu). TEST 17: TURN ON TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure:
19、From an off condition, turn on the amplifier and monitor the output noise at the time of turn on. Note: Turn on noise may increase significantly if the amplifier is cycled off and on. TEST 18: TURN OFF TRANSIENTS Spec: No dangerous transients. Initial Conditions: Controls per standard. Procedure: Fr
20、om an on condition, turn off the amplifier and monitor the output noise at the time of turn off. Note: Turn off noise may increase significantly if the amplifier is cycled off and on. TEST 19: INTERMODULATION DISTORTION Spec at 0 dB Output: 0.01%. Spec at 35 dB Output: 0.05%. Initial Conditions: Con
21、trols per standard. Procedure: Load each channel to 8 ohms. Inject a SMPTE standard IM signal (60 Hz and 7 kHz sine wave mixed at 4:1 ratio) at 320 Watts (41.0 VAC). With an IM analyzer measure less than 0.01% IMD. Repeat test at 35 dB (reference 320 Watts or 41.0 VAC) and mea- sure less than 0.05%
22、IMD. TEST 20: CLIPPING Spec: No protective action during test. Initial Conditions: Controls per standard. Procedure: Load each channel to 8 ohms. Inject a 1 kHz sine wave at each input and drive output 6 dB into clip for 10 seconds. The amplifier should not activate any protective circuits (ODEP, Fa
23、ult, or LF Protection). Figure 4. ODEP Limiting Wave Form Power Base-2 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Power Base-2 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Power Base-2 if it is marked with a yell
24、ow dot then R30 should be a 100 Ohm resistor (A10265-10001). Q42871-6 Output Module Parts List (P10305-4 Board) Power Base-2 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A10265-10001). Power Base-2 if it is marked with a yellow dot then R30 should be a 100 Ohm resistor (A