EV_CPS3,_CPS4_Power_Amp_Owners_Manual电路图.pdf
《EV_CPS3,_CPS4_Power_Amp_Owners_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《EV_CPS3,_CPS4_Power_Amp_Owners_Manual电路图.pdf(10页珍藏版)》请在收音机爱好者资料库上搜索。
1、 OWNERS MANUAL CPS 3 / CPS 4 CONTRACTOR PRECISION SERIES RadioFans.CN 收音机爱 好者资料库 The lightning flash with arrowhead symbol, within an equilateral triangle is intended to alert the user to the presence of uninsulated “dangerous voltage” within the products enclosure that may be of sufficient magnitud
2、e to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintance (servicing) instructions in the literature accompanying the appliance. IMPORTANT SAFETY INSTRUCTIONS 1. Read th
3、ese instructions. 2. Keep these instructions. 3. Heed all warnings. 4.Follow all instructions. 5. Do not use this apparatus near water. 6.Clean only with a damp cloth. 7. Do not block any of the ventilation openings. Install in accordance with the manufactures instructions. 8.Do not install near any
4、 heat sources such as radiators, heat registers, stoves, or other apparatus that produce heat. 9.Only use attachments/accessories specified by the manufacturer. 10. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power
5、-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. For US and CANADA only: Do not defeat the safety purpose of the grounding-type plug. A grounding typ
6、e plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. When the provided plug does not fit into your outlet, consult an electrican for replacement of the absolete outlet. 1. Security regulations as stated in the EN 60065 (VDE 0860 / IEC 65)
7、 and the CSA E65 - 94 have to be obeyed when servicing the appliance. 2. Use of a mains separator transformer is mandatory during maintenance while the appliance is opened, needs to be operated and is connected to the mains 3. Switch off the power before retrofitting any extensions, changing the mai
8、ns voltage or the output voltage. 4. The minimum distance between parts carrying mains voltage and any accessible metal piece (metal enclosure), respectively between the mains poles has to be 3 mm and needs to be minded at all times. The minimum distance between parts carrying mains voltage and any
9、switches or breakers that are not connected to the mains (secondary parts) has to be 6 mm and needs to be minded at all times. 5. Replacing special components that are marked in the circuit diagram using the security symbol (Note) is only permissible when using original parts. 6. Altering the circui
10、try without prior consent or advice is not legitimate. 7. Any work security regulations that are applicable at the location where the appliance is being serviced have to be strictly obeyed. This applies also to any regulations about the work place itself. 8. All instructions concerning the handling
11、of MOS - circuits have to be observed. Note: SAFETY COMPONENT (HAS TO BE REPLACED WITH ORIGINAL PART ONLY) IMPORTANT SERVICE INSTRUCTIONS CAUTION: These servicing instructions are for use by qualified personnel only. To reduce the risk of electric shock, do not perform any servicing other than that
12、contained in the Operating Instructions unless you are qualified to do so. Refer all servicing to qualified service personnel. 8 RadioFans.CN 收音机爱 好者资料库 CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Front P
13、anel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Rear Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Specifications. . . . . . . . . . . . . . .
14、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
15、. . . . . . . . . . . . . . . . . . . . . . 21 Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 DESCRIPTION First of all, we would like to express our thanks and at the same time congratulate you on the decision to b
16、uy one of our CONTRACTOR PRECISION SERIES power amplifiers. Electro-Voice CONTRACTOR PRECISION SERIES amplifiers are made to meet the highest require- ments of any on-the-road application. Thus they provide on-board protection against thermal and capacitive overload, short-circuit and the occurrence
17、 of HF or DC at the output. Additionally, special circuitry prevents the output-stage transistors from being damaged by Back-EMF. During soft start, delayed switching of the power outputs is accomplished via relays and a limiter controls the initial current inrush, preventing the mains fuse from bei
18、ng blown during the power-on operation. The mechanical construction as well is carried out following the highest precision standards of the industry. The robust steel chassis provides extreme rigidity and it is meant to live through any hard wearing condition of a touring application. Thermal stabil
19、ity is guaranteed by two 4-Mode silently running fans that offer the possibility to also use the amplifiers in a studio environment. The extensive comparator circuitry constantly monitors the input and output signals and activates the internal limiters whenever a non-linear operational state is enco
20、untered. This provides reliable protection of the connected loudspeaker systems against overload and clipping. The sound quality of the CON- TRACTOR PRECISON SERIES power amplifiers is superb. Using comprehensive dimensioned power supply units with low-interference toroidal transformers gains a head
21、room that exceeds the nominal power handling capacity by far. No V/I-Foldback-Limiter circuits are employed within the power amplifiers, making it possible to operate the amps on complex loads up to 90 phase angles without a problem. The input facilities are carried out as balanced XLRF-type sockets
22、 while the Direct-Outs on which the carried-through signals are present come as XLRM-type connectors. Using the Input Routing-switches lets you determine if the CONTRACTOR PRECISION SERIES amplifiers are operated in DUAL (stereo) or PARALLEL (monaural) mode; “mono-bridged” operation is also possible
23、. The dB-scaled level controls are to be found on the rear panel. These potentiometers guarantee precise and reliable operation. The easy readable LED display offers quick optical information on the power amplifiers momentary operational mode. For each channel individually the display shows whether
24、they are operational, a signal is present at the outputs, when the limiters are activated, and whether one of the protection circuits has been engaged or not. The power outputs CANNEL A, CHANNEL B and BRIDGED OUT are carried out as Speakon connectors. A ground-lift switch that separates the enclosur
- 配套讲稿: