1、 DN6000 User Manual CONTENTS: INTRODUCTION 2 INSTRUMENT FAMILIARISATION 3 FREQUENCY ANALYSYS MODE 7 MEMORY RECALL MODE 9 UTILITIES IN FREQUENCY ANALYSIS MODE 10 TIME ANALYSYS MODE 15 UTILITIES IN TIME ANALYSIS MODE 18 TECHNICAL SPECIFICATION 23 RadioFans.CN 收音机爱 好者资料库 2 Introduction Thank you for us
2、ing this Klark-Teknik Product To obtain maximum performance from this precision electronic product, please study these instructions carefully. Installation and operating the DN6000 is not complicated, but the flexibility provided by its operating features merits familiarisation with its controls and
3、 connections. This unit has been prepared to comply with the power supply requirements that exist in your location. Precautions Do not install this unit in a location subjected to excessive heat, dust or mechanical vibrations. Power Connection Connection is made by means of an IEC standard power soc
4、ket. The rear panel voltage label indicates the voltage required for satisfactory operation of the unit. Before connecting this unit to the mains supply, ensure the fuse fitted is the correct type and rating, as indicated on the rear panel, adjacent to the fuse holder. Safety Warning This unit is fi
5、tted with 3-pin power socket: For safety reasons the earth lead should not be disconnected. To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock do not remove covers. Refer servicing to qualified personnel only. After you have unpacked the unit Save
6、all the packing materials - they will prove valuable should it become necessary to transport or ship this product. Please inspect this unit carefully for any signs of damage incurred during transportation. It has undergone stringent quality control inspection and tests prior to packing and left the
7、factory in perfect condition If, however, the unit shows any signs of damage, notify the transportation company without delay. Only you, the consignee, may institute a claim against the carrier for damage during transportation. If necessary, contact your supplier or as a last resort, your Klark-Tekn
8、ik importing agent*, who will fully co-operate under such circumstances. RadioFans.CN 收音机爱 好者资料库 3 INSTRUMENT FAMILIARISATION Front View Rear View Display The LCD display features a large graphics area, flanked by titles for the 4 menu switches at the right hand end, and measurement information in a
9、 Status Column at the left hand end. Numeric display The 3 x 7 segment LED Numerical display gives a constantly updated read out of the level at the cursor position, visible at a distance. RadioFans.CN 收音机爱 好者资料库 4 Menu switches Four menu switches allow instant selection of various functions, depend
10、ing on the mode of the analyser. Rotary Encoder A single rotary encoder allows continuous adjustment of any selected function or measurement parameter. When nothing is selected, the encoder controls the movement of a cursor across the graphic area of the display. The Numerical display gives a consta
11、nt read out of the level at the cursor position. With peak hold active, the level of the held peak is given. With peak hold inactive, the level of the column is given. The lowest line of the status column shows the frequency or time interval at the cursor position. Mic XLR: The input signal from a m
12、icrophone is accepted on a standard XLR socket on the front panel. The DN6000 has a 48v phantom supply. The mic input sensitivity can be adjusted internally to calibrate the unit for a particular Klark Teknik 6051 microphone or the recommended Bruel normally open. Source Switch: Press and hold the s
13、ource switch to switch between microphone input (front panel) and line inputs (rear panel). For line inputs, all measurements are in dBu, where 0dBu = 0.775 volts. For microphone input, all measurements are in dB SPL (Sound Pressure Level) where 0dB SPL = 2 x 10-5 N/m2. In Frequency analysis mode, w
14、ith mic input selected, a single press toggles between 1/3 Octave and 1/6 octave spectrum analysis. With line inputs selected, single presses switch between stereo 1/3 octave, mono 1/3 octave and mono 1/6 octave spectrum analysis. Weighting Switch: Successive presses of the weighting switch cycle th
15、e unit through 3 input filter options: A weighting, C weighting and un-weighted. Peak Hold: Pressing the peak hold switch activates or deactivates the peak hold function. When peak hold is active, horizontal marks on the display show the highest level reached by each column. The peaks are held in me
16、mory when peak hold is deactivated. To clear the held peaks, press and hold the peak hold switch for 3 seconds. Source Switch Weighting Switch Peak Hold 6 Frequency Switch: Press to select frequency mode. In this mode, the graphic area of the display shows a graph of level against frequency. This al
17、lows for conventional spectrum analysis and continuous monitoring of signal level in dB SPL (sound pressure level) or dBu. Time Switch: Press to select time mode. In this mode the graphic area of the display shows a graph of level against time. This allows for measurement of RT60 (reverberation time
18、), delay time, Leq (equivalent sound pressure level) and Let (equivalent sound dose). Utilities Switch: Pressing this switch calls up a utilities menu in either Frequency or Time modes. Press the switch again to exit the utilities menu. Run switch: Press the run switch to activate or deactivate a me
19、asurement. Active run status is indicated by a green LED. Mute switch: Press this switch to mute or un-mute the test signal output. A muted output is indicated by the red LED. Store Switch: Press the store switch to store the current measurement on the display to the currently addressed memory. The
20、new measurement may be accumulated to the addressed memory or may overwrite it and increment the address. See memory sub menu for details. Frequency Time Utility Run Mute Store Switch 7 Frequency Analysis Mode: These functions are available in frequency analysis mode. To enter frequency analysis mod
21、e, press the Frequency switch. 1. Press the Level switch to select the input reference level for adjustment. Adjust the reference level with the rotary encoder. The current input reference level is shown at the top of the status column. The input level can rise 12 dB above the top of the display wit
22、hout clipping the A to D converter. Options are: dBu dB SPL 40 140 30 130 Note: Clipping of the input circuit at any frequency 20 120 affects measurements at all other frequencies, and 10 110 hence is indicated by a large on-screen warning. 0 100 -10 90 -20 80 -30 70 -40 60 -50 50 2. Press the Scale
23、 switch to select the display scale for adjustment. Adjustment the display scale with the rotary encoder. The current display scale (the distance in dB between the top and bottom of the graphic display) is shown on the second line of the status column. Options are: 60dB 30dB Note: On the 6dB scale,
24、the display has a resolution 20dB of 10 pixels per dB. The accuracy of the analyser, 15dB however, is still restricted to +/-0.3 dB. 10dB 6dB 8 3. Press the Resp. Time switch to select the response time of the display for adjustment. Adjust the response time with the rotary encoder. The current resp