1、KORG KP3 SERVICE MANUAL TABLE OF CONTENTS ASSEMBLY SKETCH (HOOKUP): 2 BLOCK DIAGRAM: 3 SCHEMATIC DIAGRAM: 4-6 TEST MODE: 7-10 PAD CALIBRATION: 11-12 PARTS LIST: 13-14 Issued Nov.6, 2006 Ver.2 Changed P11 Added Pad Cal 3/13/08 - GA RadioFans.CN 收音机爱 好者资料库 X-5500 HookupX-5500 Hookup 2121 2222 :UPPER C
2、ASE :SLIDER KNOB :VR KNOB :ENCODER KNOB :BTB 3BBC 38 :PAD FRAME :SPONGE SEAL A :SPONGE SEAL B :TOUCH PANEL :VR KNOB(2Color) :SD FRAME :SUPPORT PLATE :SHEET :WINDOW :LED FRAME :RUBBER KEY 1 :RUBBER KEY 2 :RUBBER KEY 3 :RUBBER KEY 4 :SWITCH MASK :URETHANE LEG :BOTTOM PLATE 2121 2222 RadioFans.CN 收音机爱
3、好者资料库 RadioFans.CN 收音机爱 好者资料库 R 8 6 6 8 3 3 変更 2 0 0 6 . 7 . 2 5T . K a n a i KORG KP3 TEST MODE 2006.8.30 KORG PD3 T.Kanai How to enter the simple TEST MODEEnglish by M.Y. Pushing following switches, and turn the power ON. CONNECTIONSEND or push SAMPLE BANK D to skip this item. 18. Inspection of th
4、e PAD surface. After audio measurement, push SAMPLE BANK D then Pd.2 is displayed in the LED and start the inspection of the PAD surface. When you touch the PAD, KP3 sounds. Stroke slowly all the surface of the PAD and confirm that the frequency of the sound does not change. When the sound changed t
5、o high frequency sound, the inspection is NG because other part than the part you touch is pushed. When stroking the PAD, confirm that there is not strange feeling. Confirm that sound stops when you remove the finger from the PAD. The inspection is NG when the sound does not stop after removed from
6、the PAD. Confirm that there are no dusts and etc. on the surface and beneath the PAD. 19.Preload Move the CONNECTIONSW to DIRECT to the status of waiting for the preload. PrLd is displayed in the LED display, pushing SAMPLE BANK A sw and push TAP/RANGE to execute the preload. After finished preload,
7、 KP3 restarts in normal operation and LOAd in the LED display changes to FLE.1. FLE.1 is not displayed in the LED display after few while the preload is failed. Calibrating the Touch Pad Depending on the operating environment, the touch pad segments that light when the pad is pressed might be out of
8、 position. When this happens, the following steps should be taken to re-calibrate the touch pad. Please use a plastic pointing device such as a PDA stylus or a gaming device touch pen. using a sharp or metallic object will risk damaging the touch pad surface. 1. Turn on the power while pressing the
9、PROGRAM MEMORY 7, PROGRAM MEMORY 8 and SAMPLING buttons. CAL.1 should appear on the display and the four bottom left touch pad segments should light up. 2. Using the pointing device, lightly touch the centre of the four lit segments where the grid lines cross as shown in the diagram below. !NOTE! do
10、 not move the pointing device from this position while the pad is touched. After touching this point for a short while, the calibration will move onto the next step: the next set of four segments will light and the display should read “CAL.2”. 3. Remove the pointing device from the touch pad and rep
11、eat for the next position indicated by the segment lights. Complete all four steps as shown in the following diagrams. 4. After completing the four steps, the touch pad lights will go out and P.oFF will be displayed. !NOTE! do not turn the power off until P.oFF is displayed. 5. The unit is now re-ca
12、librated. Turn the power off and on as usual and confirm that the KP3 operates correctly. 1 / 2 KORG KP3 PARTS LIST Part NumberCategoryPart NameQTY 510306510001POWER MOS FETCPH6316-TL-E (S)1 510310510502DOUBLE DIODESMC2840-T112-1 (S)1 510310511507DIODERLS-73 TE-11 (S)22 510310511506SCHOTTKY DIODERB0