klark teknik DN1414 Manual 电路图.pdf
《klark teknik DN1414 Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《klark teknik DN1414 Manual 电路图.pdf(26页珍藏版)》请在收音机爱好者资料库上搜索。
1、Klark Teknik Group, Klark Teknik Building, Walter Nash Road, Kidderminster. Worcestershire. DY11 7HJ. England. Tel:+44 1562 741515 Fax:+44 1562 745371 Email: Website: OPERATORS MANUAL Version2 DN1414 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 DECLARATION OF CONFORMITY We, of,Klark Teknik Buildi
2、ng, Walter Nash Road, Kidderminster, Worcestershire, DY11 7HJ Declare that a sample of the following product:- to which this declaration refers, is in conformity with the following directives and/or standards:- Signed:. Name: David Hoare Authority: Technical Director, Klark Teknik Group (UK) Plc Att
3、ention! Where applicable, the attention of the specifier, purchaser, installer or user is drawn to special limitations of use which must be observed when these products are taken into service to maintain compliance with the above directives. Details of these special measures and limitations to use a
4、re available on request and are available in product manuals. Klark Teknik Group (UK) Plc Walter Nash Road, Kidderminster, Worcestershire. DY117HJ. England Tel:(44)(0)1562741515. Fax: (44)(0)1562745371 CompanyRegistration No:2414018 ? ? SIGNAL PROCESSING BY DEFINITIONBETTERBYDESIGNDESIGNEDFOR APUREP
5、ERFORMANCE Product Type NumberProduct DescriptionNominal Voltage (s)CurrentFreq DN1414115VAC130mA50/60Hz 230VAC260mA Directive(s)Test Standard(s) Generic Standard Using EN55103 Limits and MethodsEN50081/1 Class B Conducted Emissions PaviEN55103 CLass B Radiated Emissions PaviEN55103 Fast Transient B
6、ursts at 2KvEN61000-4-4 Static Discharge at 4KvEN61000-4-2 Electrical Stress TestEN60204 Date: 4th February, 2000 ASubsidiary of Telex communications, Inc. RadioFans.CN 收音机爱 好者资料库 Thank you for using a Klark Teknik product After you have unpacked Introduction Installation and Connection Basic operat
7、ion Front Panel Rear Pane Rear panel blanking plate and iser multipole connectors Block Diagram Applications Appendices Specifications Schematics Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Contents . 1 Thank You For Using This Klark Teknik Product
8、Cables: Electric Fields: To obtain maximum performance from this precision electronic product, please study these instructions carefully. Installation and operating the mic splitter is not complicated, but the flexibility provided by its operating features merits familiarisation with its controls an
9、d connections. This unit has been prepared to comply with the power supply requirements that exist in your location. Do not install this unit in a location subjected to excessive heat, dust or mechanical vibration. Connection is made by means of an IEC standard power socket. The rear panel text indi
10、cates the voltage range required for satisfactory operation of the unit. Before connecting this unit to the mains supply, ensure the fuse fitted is the correct type and rating is as indicated on the rear panel, adjacent to the fuse holder. This unit is fitted with 3-pin power socket: For safety reas
11、ons the earth lead should not be disconnected. Signal ground is referenced internally to chassis via a resistor capacitor network which provides earth loop immunity. To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electrical shock do not remove covers. Refer ser
12、vicing to qualified personnel only. This product should only be used with high quality, screened twisted pair audio cables, terminated either with metal bodied 3-pin XLR connectors(with the cable screen connected to pin 1) or ” jacks.Any other cable type or configuration for the audio signals may re
13、sult in degraded performance due to electromagnetic interference. Should this product be used in an electromagnetic field that is amplitude modulated by an audio frequency signal (20Hz to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a frequency corresponding to the
14、 modulation signal may be experienced under extreme conditions (3V/m, 90% modulation). Precautions Voltage Selection and Power Connection Safety Warning Attention! AfterYou Have Unpacked The Unit ? This Side Up 2 Save all the packing materials - they will prove valuable should it become necessary to
15、 transport or ship this product. Please inspect this unit carefully for any signs of damage incurred during transportation. It has undergone stringent quality control inspection and tests prior to packing and left the factory in perfect condition. If, however, the unit shows any signs of damage, not
16、ify the transportation company without delay. Only you, the consignee, may institute a claim against the carrier for damage during transportation. If necessary, contact your supplier or as a last resort, your Klark Teknik importing agent, who will fully co-operate under such circumstances. 3 Introdu
17、ction TheDN1414MultipleDIModuleoffersacostandspace-effectivemethodofproviding14discretechannels of transformer-isolated direct injection. Housed in a rugged 3U rack enclosure, the DN1414 embodies the legendarysoundandreliabilityofKlarkTeknik. KeyFeatures iTen mono channels with XLR and jack inputs,
18、link output jack and transformer -balancedXLRoutputs. ii. Two dual channels with jack inputs, link output jacks and transformer-balanced XLRoutputs iii.-30dBpad,-15dBattenuationonallchannels. iv. InternalpowersupplywithfactoryoptionofbackupPSU. v. Fiveyearinternationalfactorywarranty. The Klark Tekn
19、ik DN1414 is an extremely high performance, 14-channel DI module housed in a 3U, rack mountingcasewithanintegralswitchmodepowersupplythatautomaticallyadaptstomainsvoltagesinthe range 100 to 240Volts (50 to 60Hz).Adual PSU is available as a factory fitted option.Applications include providingDIboxfee
20、dstoservicemonitorandFOHconsolesaswellastofacilitatethemultitrackrecording ofliveevents. Each input feeds a superbly specified input stage, which can flexibly handle both line- and instrument-level signals.TheTRSjackandXLRinputsonchannels1-10areparallelconnected,andthecircuitdesignallows the DN1414
21、to handle either balanced or unbalanced signals without loss. A20k ohm input impedance is presentedwhentheXLRinputconnectorisused,thisimpedanceisswitchedoutwhenthejackinputisused, to avoid high-frequency loading effects when the DN1414 is used with unbuffered guitar pick-ups. All connectors are moun
22、ted on the front panel for easy access.Two pad/attenuator switches (-30dB and -15dB) may be used individuallyor in combinationto provide unity, -15 dB, -30 dB or 45 dB gain. EachDI channel outputisalsofittedwithagroundliftswitch. InstallationAnd Connection TheKlarkTeknikDN1414isdesignedforstandard19
23、rackmountingandoccupies3Uofrackspace.Avoid mounting the unit directly above or below power amplifiers or power supplies that radiate excessive magnetic fields or heat. Ensure that the ventilation apertures on either side of the unit are not blocked or obstructed. This unit must be earthed. If ground