Line_6_JM4_Looper_Service_Manual电路图.pdf
《Line_6_JM4_Looper_Service_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Line_6_JM4_Looper_Service_Manual电路图.pdf(54页珍藏版)》请在收音机爱好者资料库上搜索。
1、Line6, Inc. Customer Service and Repair 3850-A Royal Ave. Simi Valley, CA 93063 P. 818-575-3600; F. 818-575-3961; E. JM4 Looper Service Manual RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 RadioFans.CN 收音机爱 好者资料库 F8 Floor Jam UI Rev C.sch-1 - Tue Apr 15 22:10:14 2008 F8 Floor Jam UI Rev C.sch-2 -
2、Tue Apr 15 22:10:16 2008 F8 Floor Jam UI Rev C.sch-3 - Tue Apr 15 22:10:24 2008 F8 Floor Jam UI Rev C.sch-4 - Tue Apr 15 22:10:24 2008 05/30/08 Page 1 of 6 LINE 6 CONFIDENTIAL FLOOR JAM MAIN PCBA ASSEMBLY INSTRUCTIONS Rev. C FLOOR JAM PCBA MAIN:50-02-0271 (Refers to Main PCB, Rev.A: (35-00-0271) BOT
3、TOM TOP 05/30/08 Page 2 of 6 LINE 6 CONFIDENTIAL 1. DO NOT WATER WASH THE BOARD: The potentiometers and tact switches are sensitive to water washing. If wave soldering is preferred, we recommend using a no-clean flux wave soldering process, rather than a process that requires washing. The fluxing pr
4、ocess wave must be controlled so as not to have flux migrate inside the switch through the top of the housing. Good venting is required. No-clean flux vapors can enter the switch if adequate venting is not available. The vapors will condense on the internal contacts and become an insulator when they
5、 solidify. 2. “DO NOT INSTALL” COMPONENTS: Do not install the following components: R117 R125 C158 C142 D3-5 D11 D13 H2-3 J11 3. JACKS: All Jacks, including J1, J3-6 (21-00-6616), J2 (21-08-0002), J7-8 (21-12-0035), and J9 (21- 00-0014) must be mounted flush with the PCB and lined up with the silksc
6、reen outline within +/-1 degree of accuracy. ALL jacks are to be mounted on the TOP SIDE of the PCB. See Photo: 4. SD CARD SOCKET: J10 (21-18-0900) must be mounted flush with the PCB and lined up with the silkscreen outline within +/-1 degree of accuracy. The SD Card is mounted on the TOP SIDE of th
7、e PCB. See Photo: Make sure SD Card is flush before soldering to PCB. 05/30/08 Page 3 of 6 LINE 6 CONFIDENTIAL 5. HEADERS: H1 (21-20-0040) and H2 (21-20-0206), are to be mounted flush against the PCB. Confirm that header H1 is installed correctly by ensuring that pin 1 on the header (indicated by ar
8、row on header) lines up with pin one on PCB silkscreen (indicated by the square pad). Also, be sure H2 is installed on the BOTTOM side of PCB and is aligned with the silkscreen outline within +/-1 degree of accuracy. See Photos. ARROW SQUARE PAD PIN ONE SILKSCREEN ON BOTTOM SIDE OF PCB CORRECTLY SEA
9、TED 05/30/08 Page 4 of 6 LINE 6 CONFIDENTIAL 6. REGULATOR ICs: U19 (12-02-7812), U20 (12-02-7912), U21 and U23 (12-02-7805), and U22 (12-00-0317) are to be installed with the case of each IC resting at a 90 degree angle, flush to the PCB. Be sure that the case of each regulator is lined up with the
10、silkscreen outline within +/-1 degree of accuracy. See Photo: 7. REGULATOR STANDOFFS: Securely install HEX STANOFF (30-12-0009 STANDOFF HEX .250 6-32 M-F 0.250-IN AL) at all regulators (U19-23) using Screw (30-00-0043) See Photo: Standoffs are not to size picture is for reference only. 05/30/08 Page
11、 5 of 6 LINE 6 CONFIDENTIAL 8. POTS: Be sure both horizontally mounted Pots (01-48-9208 and 01-48-9209) are installed flush to the PCB and are aligned with the silkscreen outline within +/-1 degree of accuracy. See Photo. 9. GROUND FINGERS: ALL grounding fingers are mounted flush against the PCB edg
12、e. They are mounted with their center clip hole on the BOTTOM side of the PCB. The “curl” of the grounding finger should curve toward the TOP SIDE (toward the jack). They should then be manually soldered on the BOTTOM SIDE. See Photos: BOTTOM SIDE TOP SIDE 10. CRYSTALS AND INSULATORS: Crystals Y1 (P
13、/N 11-00-1002) and Y2 (11-00-1001) are to be installed with insulator (30-15-0007) and must be mounted flush against PCB. See Photos: INSULATOR TAB CURLS UPWARD SOLDERED ON BOTTOM SIDE CRYSTAL INSTALLED WITH INSULATOR 05/30/08 Page 6 of 6 LINE 6 CONFIDENTIAL 11. RADIAL LEAD CAPACITORS: Check orienta
14、tion of all electrolytic capacitors. All radial lead capacitors are to be mounted perpendicular to the PCB within +/- 5 degree of accuracy. They are to be mounted as low as possible to the PCB without sacrificing the lead to package-body integrity. RTV should be added as shown in photos below. BOTTO
15、M SIDE TOP SIDE SM RADIAL LEAD CAPACITORS PCBA ASSEMBLY INSTRUCTIONS REVISION CHANGE HISTORY REVISION NOTES DATE RELEASED BY A Released for beta build and production, unless revised. 03/13/08 Anthony Pascuzzo B Updated to include Standoff Heatsinks. 03/27/08 Anthony Pascuzzo C Updated Standoffs (30-
16、12-0009) to Heatsinks. 05/30/08 Mike Hatzinger 03/27/08 Page 1 of 7 LINE 6 CONFIDENTIAL FLOOR JAM USER INTERFACE_BREAKAWAY PCBA ASSEMBLY INSTRUCTIONS Rev. B USER INTERFACE UPPER PCBA: (50-02-0272) Refers to User Interface Upper PCB Rev. A: (35-00-0272) USER INTERFACE MIDDLE PCBA: (50-02-0272-1) Refe
17、rs to User Interface Middle PCB Rev. A: (35-00-0272-1) USER INTERFACE LOWER PCBA: (50-02-0272-2) Refers to User Interface Lower PCB Rev. A PCB: (35-00-0272-2) C 03/27/08 Page 2 of 7 LINE 6 CONFIDENTIAL 1. DO NOT WATER WASH THE BOARD: The potentiometers and tact switches are sensitive to water washin
18、g. If wave soldering is preferred, we recommend using a no-clean flux wave soldering process, rather than a process that requires washing. The fluxing process wave must be controlled so as not to have flux migrate inside the switch through the top of the housing. Good venting is required. No-clean f
19、lux vapors can enter the switch if adequate venting is not available. The vapors will condense on the internal contacts and become an insulator when they solidify. 2. BREAKAWAY PCB: DO NOT BREAK APART THE FIVE SECTIONS OF THE PCB UNTIL AFTER WAVE SOLDER. 3. DO NOT INSTALL PARTS: C10-11 4. POTENTIOME
20、TERS: All potentiometers are to be mounted on the TOP SIDE of the User Interface Lower PCB (35-00-0272-2). Potentiometers are to be flush to the PCB, and as straight as possible (Within +/- 1 degree). See Photo. 5. RADIAL LEAD CAPACITORS: RADIAL LEAD SM CAPACITORS: Check orientation of electrolytic
21、capacitors C3 and C7 located on the UI Upper PCB (35-00-0272). Radial lead capacitors are mounted flush with the PCB and lined up with the silkscreen outline within +/-1 degree of accuracy. See Photos. 03/27/08 Page 3 of 7 LINE 6 CONFIDENTIAL 6. RIBBON CABLES: 1. 40-PIN RIBBON CABLE: One 40-pin ribb
22、on cable (21-30-0052) is to be staked flush on the TOP SIDE of the User Interface Upper breakaway PCB (35-00-0272) at H1. See Photo. 2. 10-Pin Ribbon Cable (21-30-0053-2) should be staked from J100 on User Interface Middle PCB (35-00- 0272-1) to J1 on UI Upper PCB (35-00-0272). See Photo. 3. 14-Pin
23、Ribbon Cable (21-30-0054) should be staked from J102 on User Interface Middle PCB (35-00-0272- 1) to J2 on UI Upper PCB (35-00-0272). See Photo. 03/27/08 Page 4 of 7 LINE 6 CONFIDENTIAL 4. 10-Pin Ribbon Cable (21-30-0053-1) should be staked from J10 on User Interface Lower PCB (35-00-0272- 2) to J10