1、pagecontents Section 2 Installation pagecontents 2-2Installation of 2200 2-7Figure 2-1: AC Line Cord Wire Standard 2-9Figure 2-2: Wiring the 25-pin Remote Control Connector 2-17Basic System Setup 2-27System Setup Controls 2-27I/O CALIB (I/O Calibration) 2-32Stereo Encoder (and processing Pre-Emphasi
2、s) 2-34Remote Interface 2-35TEST Mode CAUTION The installation and servicing instructions in this manual are for use by qualified personnel only. To avoid electric shock, do not perform any servicing other than that contained in the Operating Instructions unless you are qualified to do so. Refer all
3、 servicing to qualified service personnel. OPTIMOD-FM 2200INSTALLATION 2-1 RadioFans.CN 收音机爱 好者资料库 Installation of 2200 Allow about 2 hours for installation. Installation consists of: (1) unpacking and inspecting the 2200, (2) optional resetting of jumpers for 2200 options (composite output impedanc
4、e, input termination, input sensitiv- ity), (3) checking the line voltage setting, fuses and power cord, (4) mounting the 2200 in a rack, (5) connecting inputs, outputs and power, (6) setting the GROUND LIFT switch, (7) and optional connecting of remote control leads. When you have finished installi
5、ng the 2200, proceed to “System Setup,” on page 2-16. 1. Unpack and inspect. AIf you note obvious physical damage, contact the carrier immediately to make a damage claim. Packed with the 2200 are: 1Operating Manual 1Quick Setup Guide 1Line Cord 2 12A Replacement Fuses for “U” and “J” Versions 2250mA
6、 Replacement Fuses for “E” Version 1Orban green screwdriver (Xcelite R3323) 1Booklet: Audio Quality in the FM Plant BSave all packing materials! If you should ever have to ship the 2200 (e.g., for servicing), it is best to ship it in the original carton with its packing materials because both the ca
7、rton and packing material have been carefully designed to protect the unit. CComplete the Registration Card and return it to Orban. (please) The Registration Card enables us to inform you of new applications, performance improvements, and service aids that may be developed, and it helps us respond p
8、romptly to claims under warranty without our having to request a copy of your bill of sale or other proof of purchase. Please fill in the Registration Card and send it to us today. (The Registration Card is located after the cover page). We do not sell or give away our customers names to anyone. 2-2
9、 INSTALLATION OPTIMOD-FM 2200 RadioFans.CN 收音机爱 好者资料库 2. Change standard factory configuration, if required. Skip this step if your installation does not have any special requirements. The 2200 is supplied from the factory with its jumpers set to the configuration correct for most installations. Ste
10、reo Encoder Composite Output Impedance 0 Input Impedance10k Input Sensitivity10dBu or greater (+5dBu to +27dBu peak) ATo change any jumpers you must remove the top cover of the 2200 to access the main circuit board. (Make sure power is not connected.) Remove all screws holding the cover in place, th
11、en lift it off. (Be careful not to strip threads when opening the cover.) BRefer to Figure 2-1 to find the jumpers on the main circuit board and to position them according to your application. The following information is provided to explain each jumper and its settings in detail. Stereo encoder com
12、posite output impedance. Do not change the default 0 jumper setting unless your installation needs 75 source impedance. The stereo encoder is shipped from the factory with 0 source impedance. This is correct for virtually all installations. However, the 2200 stereo encoder can be changed to 75 sourc
13、e impedance if desired. The frequencies in the stereo baseband are low by comparison to RF or video, and the characteristic impedance of coaxial cable is not 75 at lower frequencies, so the transmission system will have more accurate amplitude and phase response (and thus, better stereo separation)
14、if the cable is driven by a very low source impedance (0) and is terminated with greater than 1k at the exciter. However, a few broadcast organizations require that FM composite be transmitted in impedance-matched coaxial cable with 75 source and load impedances. To change the source impedance of on
15、e or both of the composite outputs: To change the source impedance of composite output #1, move jumper JA to the “75” position (Fig 2-1). To change the source impedance of composite output #2, move jumper JB to the “75” position (Fig 2-1). Analog left/right input termination. Do not change the defau
16、lt setting unless your installation requires 600 termination on the analog left/right inputs. The analog left/right inputs are shipped from the factory with balanced bridging (10k) input impedance. However, the 2200 analog inputs can be changed to 600 input impedance. OPTIMOD-FM 2200INSTALLATION 2-3
17、 RadioFans.CN 收音机爱 好者资料库 To change the input impedance of the analog left/right inputs: Move jumpers J301 and J305 according to Figure 2-1. Jumper J301 sets the left channel and jumper J305 sets the right channel. Set analog left/right input sensitivity. Skip this step if your installation will supp
18、ly the 2200 with nominal input level of 10dBu or greater (+5dBu to +27dBu peak). The analog left/right inputs are shipped from the factory with input sensi- tivity to accommodate inputs whose absolute maximum peak level is between +5dBu and +27dBu. If VU meters are used, +5dBu to +27dBu absolute pea
19、k corresponds to a 0VU level of approximately 9dBu to +13dBu. If PPMs are used, +5dBu to +27dBu absolute peak corresponds to a PPM level of approximately 2dBu to +20dBu. However, in unusual circumstances where the input level is very low, the 2200 analog inputs can be changed for greater sensitivity
20、. This usually occurs only when the studio-to-transmitter link is a long telephone or post line with a passive equalizer at the receive end and no amplifier to make up the loss of the line and the equalizer. To increase the input sensitivity of the analog input to accommodate absolute peak levels of
21、 17dBu to +5dBu (nominal levels down to 30dBu): Move jumpers J302, J303, J306, J307 and J308 according to Figure 2-1. Jumpers J302 and J303 set the left channel and jumpers J306 and J307 set the right channel. Jumper J308 sets the control circuit to recognize the new input sensitivity. CReplace the
22、2200 top cover. Replace all screws snugly. (Be careful not to strip threads by fastening the screws too tightly.) 2-4 INSTALLATION OPTIMOD-FM 2200 OPTIMOD-FM 2200INSTALLATION 2-5 2200 Rear Panel Voltage Selector (for Model Numbers 2200/U, 2200-D/U, 2200/E and 2200-D/E) can be set to 115V (for 100-13
23、2V operation) or 230V (for 200-264V operation); (for Model 2200/J and 2200-D/J) set to 115V (for 89-120V operation). Fuse values can be changed to support 115V or 230V operation. Fuse must be 3AG Slow-Blow, 12-amp for 115V, or 14-amp (250mA) “T” type for 230V. Power Cord is detachable and is termina
24、ted in a “U-ground” plug (USA standard), or CEE7/7 plug (Continental Europe), as appropriate to your 2200s Model Number. GND LIFT (Ground Lift) Switch can be set to GND (to connect the 2200s circuit ground to its chassis), or to LIFT (if you are using the 2200s stereo encoder, and are driving its co