Midas_XL42_Manual电路图.pdf
《Midas_XL42_Manual电路图.pdf》由会员分享,可在线阅读,更多相关《Midas_XL42_Manual电路图.pdf(28页珍藏版)》请在收音机爱好者资料库上搜索。
1、OPERATORS MANUAL XL42 Telex Communications (UK) Ltd. Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel: +44 1562 741515 Fax: +44 1562 745371 Website: XL42 Dual Channel Strip Operators Manual DOC02-XL42 Issue B - December 2005 Telex Communications (UK) Ltd. In l
2、ine with the companys policy of continual improvement, specifications and function may be subject to change without notice. E thus creating a custom 10 into 2 mixer via the output daisy chain feature. The resulting L and R outputs may then be routed to the master console via any convenient point, su
3、ch as, a pair of aux returns, group inputs, matrix inputs etc. As a stand-alone unit, the XL42 is ideally suited to applications requiring a high quality front end, such as stereo recording etc. IntroductionIntroduction XL42 Operators Manual - Page 1 Installation Precautions Voltage Selection and Po
4、wer Connection Safety Warning Attention! Cables Electric Fields Mains power to the XL42 is supplied by means of a standard fused IEC power socket. The XL42 is designed to operate at nominal mains voltages of 115V and 230V AC at either 50 or 60 Hz, however, upon first use (and whenever the mains supp
5、ly is changed) the input voltage selector on the rear of the unit must be set to reflect the local power supply. This information is also printed on the rear of the unit, below the mains inlet socket. This device must be earthed and must use an approved mains fuse. Before connecting to the mains sup
6、ply, ensure the fuse fitted is the correct type and rating as indicated on the rear panel (adjacent to fuse holder) and that the correct mains supply voltage is selected. To completely disconnect this equipment from the AC mains, set the power switch to the off position. The power switch shall remai
7、n readily operable. Do not expose this equipment to dripping or splashing and ensure that no objects filled with liquids, such as vases, are placed on the equipment. For safety reasons the earth lead for this unit should never be disconnected. In the event of ground loop problems, under no circumsta
8、nces must the mains earth be removed. Instead, disconnect the signal screen at one end of the connecting cables. Please note that this can only be done when the unit is being used within a balanced system. To prevent shock or fire hazard, do not expose the unit to rain or moisture. To avoid electric
9、al shock do not remove covers. Refer servicing to qualified personnel only. The inputs and outputs are balanced on conventionally wired XLRs (pin 1 screen, pin 2 hot and pin 3 cold). This product should only be used with high quality, screened twisted pair audio cables, terminated with metal-bodied
10、3-pin XLR connectors. Any other cable type or configuration for the audio signals may result in degraded performance due to electromagnetic interference. The +48V phantom power can only be used with balanced cables. Should this product be used in an electromagnetic field that is amplitude modulated
11、by an audio frequency signal (20Hz to 20kHz), the signal to noise ratio may be degraded. Degradation of up to 60dB at a frequency corresponding to the modulation signal may be experienced under extreme conditions (3V/m, 90% modulation). No permanent damage or degradation of performance will be cause
12、d by these conditions. Note: Do not install this unit in a location subjected to excessive heat, dust or mechanical vibration. Allow for adequate ventilation around the unit, making sure the units vents are not obstructed. To avoid excessive heating of the unit, avoid mounting the unit directly abov
13、e power amplifiers or other devices that radiate significant amounts of heat. Where necessary, use fan-cooled racks. Before You StartBefore You Start XL42 Operators Manual - Page 2 Before unpacking the XL42, check packaging for signs of damage, as this could be an indication of damage to the unit in
14、side. After unpacking the XL42, check the unit for signs of damage to the casing. Damage to consignments must usually be reported to the courier within 24 hours in order for a claim to be made. Please retain the packaging for your XL42, as it will prove useful if you need to transport the unit. Plea
15、se also retain the XL42s Operators Manual (this document) and any other associated documentation. After You Have Unpacked the UnitAfter You Have Unpacked the Unit XL42 Operators Manual - Page 3 After You Have Unpacked the UnitAfter You Have Unpacked the Unit XL42 Operators Manual - Page 4 EQ section
16、 Output section Power On/Off switch: Conventional latching type switch, which is on when in its fully in position and off when fully out. The action of the switch is firm but does not require excessive force, which may damage the unit. A red LED, to the left of the power switch, illuminates to indic
17、ate that the XL42 is receiving mains power. Input section The XL42 is a highly featured 1U 19” rackmount, dual channel strip. The unit is split into two identical channel strips, each with identical functionality but having independent inputs and outputs. Front PanelFront Panel XL42 Operators Manual
18、 - Page 5 Input section mic/line gain control knob: Gives a continuously variable input gain control depending upon the input selected, where: Mic: +15dB to +70dB gain Mic (PAD enabled): -10dB to +45dB PAD switch:line/padTheswitch provides 25dB of attenuation to the input signal and allows the conne
19、ction of high output microphones or line level signals. If using the XL42s optional transformer- coupled input, the pad greatly reduces the risk of saturation at very low frequencies. +48 switch: Phantom power +48V switch allows connection of devices that require phantom power, such as, condenser mi
20、crophones, direct inject (DI) boxes etc. switch: Phase switch inverts the input signal by applying a 180 phase shift. Front PanelFront Panel XL42 Operators Manual - Page 6 The bass, lo-mid, hi-mid and treble bands use dual concentric rotary controls. The outside ring controls the band cut and boost
21、in the range -15dB to +15dB. The inner ring of the dial controls the bandwidth of the filter in the range 0.1 to 2 octaves (with a centre detent at 0.5 octave). EQ section freq (bass) control: Selects frequency at which the bass equaliser band acts; continuously variable from 20Hz to 400Hz. bass dua
22、l concentric rotary control knob: bell Bass band gain/attenuation adjustment is via inner control knob. Bass bandwidth is adjusted using the outer control ring, enabled viaswitch (immediately below). bell (bass) switch: Conventional latching switch enables/disables parametric EQ for the bass band. W
23、hen switch is in fully in position, equaliser band will work in full parametric mode. Otherwise, equaliser band acts like a traditional MIDAS shelving response EQ. freq (hi-mid) control: Selects frequency at which the hi-mid equaliser band acts; continuously variable from 400Hz to 8kHz. eq switch: E
24、nables/disables equaliser in the signal path. freq (lo-mid) control knob: Lo-mid control selects frequency at which the lo-mid equaliser band acts and is continuously variable from 100Hz to 2KHz. lo-mid dual concentric rotary control knob: Lo-mid band gain/attenuation adjustment is via inner control
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Midas_XL42_Manual 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


