Neve 33609jd_technical_handbook_issue1电路图.pdf
《Neve 33609jd_technical_handbook_issue1电路图.pdf》由会员分享,可在线阅读,更多相关《Neve 33609jd_technical_handbook_issue1电路图.pdf(25页珍藏版)》请在收音机爱好者资料库上搜索。
1、 2003 AMS Neve plc own the copyright of all information and drawings contained in this manual which are not to be copied or reproduced by any means or disclosed in part or whole to any third party without written permission. As part of our policy of continual product improvement, we reserve the righ
2、t to alter specifications without notice but with due regard to all current legislation. Disclaimer: The information in this manual has been carefully checked and is believed to be accurate at the time of publication. However, no responsibility is taken by us for inaccuracies, errors or omissions no
3、r any liability assumed for any loss or damage resulting either directly or indirectly from use of the information contained within it. AMS NEVE INC., NEW YORK TEL: +1 (212) 965 1400 FAX: +1 (212) 965 9306 AMS NEVE INC., HOLLYWOOD TEL: +1 (818) 753 8789 FAX: +1 (818) 623 4839 AMS NEVE PLC BILLINGTON
4、 ROAD BURNLEY LANCS BB11 5UB ENGLAND TELEPHONE: +44 (0) 1282 457011 FAX: +44 (0) 1282 417282 H E A D O F F I C E TELEPHONE: +44 (0) 20 7916 2828 FAX: +44 (0) 20 7916 2827 LO N D O N O F F I C E N O R T H A M E R I C A N O F F I C E S e-mail: enquiryams- http:/www.ams- Technical Handbook 527-148 Issu
5、e 1 33609/JD Limiter/Compressor RadioFans.CN 收音机爱 好者资料库 Limiter/Compressor Technical HandbookPage 1 1. Limiter/Compressor Unit Introduction The limiter/compressor unit contains two identical, isolated channels which are suitable for mono, stereo or independent operation; units can be linked for mult
6、i-channel use. When limiting and compression is not required, both channels may be by-passed. Both mono, stereo and by-pass functions are switched by logic-controlled relays. Depending on the position of an EXTernal INTernal switch, these functions are either operated by front panel switches or exte
7、rnally controlled by a rear panel connector. The above switches are internally illuminated from the Logic to show the operational mode of the unit, and external tallies are available via the rear panel connector. The reset position of the relays is BY-PASS and MONO: when power is disconnected or swi
8、tched off, the unit is in BY-PASS mode. The limiter/compressor unit contains the following four identifiable sections: Limiter/Compressor board (11475): This is a motherboard which contains the attenuator control element, the 10340-C amplifier and the limiting and compression sidechain electronics.
9、The external control potentiometers, switches and gain reduction meters (which indicate the overall gain reduction in each channel during limiting and compression) are mounted on the front panel. Input and output sockets mounted on the rear panel. A D.C power and relay logic board, which provides a
10、regulated +24V supply for the 11475 board, and +5V for logic circuits controlling the relay switching. Limiter/Compressor Board (11475) This board contains the main audio signal processing circuits of the limiter/compressor unit. The operation of the board is described elsewhere. Front Panel Switche
11、s The rotary control switches located on the front panel of the unit are multi-contact multi-layer rotary switches. Electrical loading of the switches is provided via resistors connected across the contacts. RadioFans.CN 收音机爱 好者资料库 Limiter/Compressor Technical HandbookPage 2 Mains Power Supply The 2
12、4V DC input, derived from the main supply, required by the limiter/compressor board (11475) is supplied by a power supply unit located in the limiter/compressor unit. The power supply unit comprises a toroidal mains input transformer (TF14201), a regulator circuit (part of 11720), and associated com
13、ponents. The arrangement is shown as part of the limiter/compressor block diagram EB20515. Mains power is applied via an IEC inlet connector to the front panel mounted switch POWER. The switch illuminates when the unit is switched on. Input voltages of 100V, 120V, 220V or 240V AC can be selected usi
14、ng the voltage selector mounted on the rear panel. Primary circuit protection is provided by a 500mA anti-surge fuse for 100V, 120V, 220V or 240V operation, the fuse is located in the body of the voltage selector. The 24V AC output of the toroidal transformer is connected to the secondary protection
15、 fuse, a 500mA anti-surge type, mounted on the rear panel of the unit. Specification Frequency Response20Hz to 20kHz +/-0.5dB, measured at 0dBu relative to 1kHz. Noise-75dBu with input terminated in 600 ohms, by-passed IN, compress and limit OFF; -55dBu with compress IN and gain make-up at maximum.
16、Limit Level+4dBu to +15dBu, measured with limit recovery set at 50ms, level at +8dBu using a 1kHz sine-wave at +20dBu and +8 control adjusted to give +8dBu output. Limit Ratiowith input level at 10dBu, increased to +20dBu the change in output level should be 0.1dB, +/-0.1dB. Attack Timeslow: 4ms, +/
17、-1ms fast: 2ms, +/-1ms being the time taken for a signal to return to within 1dB of its original value, using an increase in input level of 10dB on an input adjusted to +10dBu at 1kHz. Limit Recoverythis is the time taken by the control voltage to reach a new value when an input at +20dBu is reduced
18、 in value by 10dB. The recovery times can be set to 50ms, 100ms, 200ms, 800ms, AUTO 1 1500ms, AUTO 2 3000ms (all +/-50%). Gain Make-upsettings 0 to 20dB correspond with output level +/-0.5dB. RadioFans.CN 收音机爱 好者资料库 Limiter/Compressor Technical HandbookPage 3 Compress Ratiorecovery set to 100ms thre
19、shold to -20dBu input 1kHz at 0dBu for each setting of the Compress Ratio Switch the input level is increased by 10dB and the change in output level should be: Compress Ratio Switch O/P Level Change (dBu) Tolerance (dB) 1.5 : 16.5 1 2 : 15.0 1 3 : 13.5 1 4 : 12.5 0.5 5 : 11.5 0.5 Compress Recovery10
20、0ms, 400ms, 800ms, 1500ms AUTO 1 800msAUTO 2 1500ms Distortion0.075% maximum (bypass IN, Compress and Limit OUT, input level at +9dBu, 1KHz). 0.2% maximum (Compress IN ratio 6:1, Gain make-up to MAX, Recovery 800ms, Threshold 18dBu). 0.45% maximum (Limit IN, Compress OUT, Recovery 800ms. Input level
21、 +22dBu, Threshold 18dBu). Power Consumption5.3VA DimensionsLength:482mm (19in) Height:88mm (3.26in) Depth:255mm (10.03in) Limiter/Compressor Technical HandbookPage 4 2. Switch Assembly Information Assembly information for the following switches is included in this section: Switch Function Compress
22、RatioPL20233 Gain Make-UpPL20234 Compress ThresholdPL20235 Compress RecoveryPL20236 Limit RecoveryPL20237 Limit levelPL20238 Limiter/Compressor Technical HandbookPage 5 3. Limiter/Compressor Board (11475) The main audio path through each channel is via T2, D14, to D17, TR16 and TR17, TR3 and TR4, T1
23、, T3 and the bypass switch. The remaining components on the board and some external components from the sidechain. The incoming audio signal is applied to the transformer T2 which feeds a balanced attenuator pad formed by R47 to R49 and R11. The active attenuator of the limiter/compressor is formed
24、by a balanced diode bridge D14 to D17. A DC Control voltage, derived b the limiter or compressor sidechain sections, is used to forward bias the diodes in the bridge and thereby alter the effective value of the attenuator resistance. The attenuator pad reduces the input signal level such that the si
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Neve 33609jd_technical_handbook_issue1 电路图 33609 jd_technical_handbook_issue1
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf