1、 SERVICE NOTES Issued by RJA Copyright 2006 ROLAND CORPORATION All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION. 17058371E0 JAN.2006E-09 Printed in japan(0400)(TP-KW) TABLE OF CONTENTS CAUTIONARY NOTES .2 SPACIFICATIO
2、NS.3 LOCATION OF CONTROLS .4 LOCATION OF CONTROLS PARTS LIST.4 LOCATION OF CONTROLS PARTS LIST.5 EXPLODED VIEW.6 EXPLODED VIEW PARTS LIST.7 EXPLODED VIEW 2.8 EXPLODED VIEW 2 PARTS LIST.9 EXPLODED VIEW 3.10 EXPLODED VIEW 3 PARTS LIST.11 KEYBOARD PARTS LIST.12 GREASING SPREADING POSITION.12 Disassembl
3、y Procedure.13 IMAGE OF REFERENCE.14 PARTS LIST.16 CHECKING THE VERSION NUMBER.19 USERS DATA SAVE AND LOAD.19 FACTORY RESET.20 SYSTEM UPDATE.21 TEST MODE.22 BLOCK DIAGRAM.28 CIRCUIT BOARD(MAIN) .30 CIRCUIT DIAGRAM(MAIN 1/3) .32 CIRCUIT DIAGRAM(MAIN 2/3) .34 CIRCUIT DIAGRAM(MAIN 3/3) .36 CIRCUIT BOAR
4、D(PANEL(L/R)/PHONES).38 CIRCUIT DIAGRAM(PANEL(L/R)/PHONES).40 ERROR MESSAGES.42 RadioFans.CN 收音机爱 好者资料库 2 JAN.2006 CAUTIONARY NOTES Before beginning the procedure, please read through this document. The matters described may differ according to the model. BACK UP USER DATA! User data may be lost dur
5、ing the course of the procedure. Refer to “USERS DATA SAVE AND LOAD” in the Service Notes and save the data. After completing the procedure, restore the backed-up data to the product. PART REPLACEMENT When replacing components near the power-supply circuit or a heat-generating circuit (such as a cir
6、cuit provided with a heat sink or including a cement resistor), carry out the procedure according to the instructions with respect to the part number, direction, and attachment position (mounting so as to leave an air gap between the component and the circuit board, etc.). PARTS LIST A component who
7、se part code is * cannot be supplied as a service part because one of the following reasons applies. Because it is supplied as an assembled part (under a different part code). Because a number of circuit boards are grouped together and supplied as a single circuit board (under a different part code)
8、. Because supply is prohibited due to copyright restrictions. Because reissuance is restricted. Because the part is made to order (at current market price). CIRCUIT DIAGRAM In the circuit diagram, NIU is an abbreviation for NOT IN USE. The circuit board and circuit-board diagram show silkscreened in
9、dications, but no components are mounted. RadioFans.CN 收音机爱 好者资料库 3 E-09 SPACIFICATIONS E-09(40034):INTERACTIVE ARRANGER Keyboard 61 keys (with velocity) Sound Generator Maximum Polyphony 64 voices Parts 16 parts + Keyboard part Wave Memory 32 M bytes (16-bit linear equivalent) Tones Tones: 614 + 25
10、6 (GM2) Drum Sets: 61 + 9 (GM2) Effects MFX: 47 types Reverb: 8 types Chorus: 8 types Transpose 12 to +12 (in semitones) Arranger Tempo 20 to 250 Styles 130 styles Band Orchestrator 3 types: Drum the number of files varies according to the version). You play back these files in numerical sequence. R
11、equired Equipment SMF Player MIDI Cable UPDATE CD-ROM (#17041741) Procedure 1.Use a MIDI cable to connect MIDI OUT on the external sequencer to MIDI IN on the E-09. If the sequencer is capable of chain play, make the settings to enable chain play of the SMF data. 2.While holding down the FAMILY and
12、TEMPO buttons, switch on the power to the unit. (Continue holding down the buttons until the following screen appears.) fig.Update-01 3.Pressing the 1 (PIANO) button displays “_”, enabling the standby state for receiving MIDI data. fig.Update-02 4.Check the display to make sure the E-09 is at standb
13、y for receiving MIDI data, then play back all “*.mid” files on the E-09 SMF Update Disk in numerical sequence. While MIDI data is being received, the “_” displayed changes to “*_”. When data transmission of one file ends, the display changes to “Waiting.”. Continue by playing back the next file. Upd
14、ating can be accomplished more easily by using a sequencer provided with a chain-play feature, such as the Roland MC-80. 5.When the update ends, the checksum is calculated and displayed on the LCD. fig.Update-03 6.Make sure the “*” portion displayed matches the checksum for the updated version. 7.Re
15、set the power to the unit and perform a factory reset. (Refer to “How to Perform a Factory Reset”.) If the upgrade is unsuccessful, redo the operation from step 1. 1:MIDI 2:- 3:S _ * *(*) 22 JAN.2006 TEST MODE Backing Up the User Data All user data is deleted when Test Mode is carried out. Also be s
16、ure to reload the user data after competing Test Mode. Required Equipment AC voltmeter (ex. NF M-177) Head Phone Speakers (ex. MA-10D) x2 EXP Pedal Hold Pedal Audio Cable x2 MIDI cable Test items The following tests are provided for the E-09. For detailed information about the tests, refer to the co
17、rresponding sections. 0. Test Mode Top page 1. Shock TEST 2. Memory TEST 3. MIDI TEST 4. SOUND TEST1 (OUT1,2 HEADPHONE) 5. SOUND TEST2 (Low, Mid, High) 6. LCD TEST 7. A/D TEST 8. Pedal TEST 9. Switch & LED TEST 10. KEYBOARD TEST 11. Noise TEST 12. Factory Reset Important Notes on Starting Testing Af
18、ter entering the Test mode, no user data is lost until “12.Factory Reset” is executed. Save user data beforehand using an external sequencer and computer only when executing “12.Factory Reset”. (Refer to the sections on USERS DATA SAVE AND LOAD.) Some test items output confirmation-use audio. Before
19、 you start, connect headphones and a monitor speaker. How to Enter the Test Mode Holding down the 8 (WORLD 1) + SPLIT + KEYBOARD TOUCH buttons and switching on the power to the unit displays the top page for the Test mode (CPU and ROM versions). Continue to hold down the buttons until the Test mode
20、top page appears. How to Move among the Test Items Use the USER PROG + FAMILY buttons to move to the next test. Test item details Detailed Description of the Test Mode. 0.Test Mode Top page (E-09 PD Test) fig.lcd-ver 1.Verify the versions of the CPU and program ROM. If the versions are not appropria
21、te, perform an upgrade. (Refer to “How to Update the System.”) For information on the latest versions, check the Service Information. 2.Pressing the TEMPO + / YES button starts the Test mode. 1.SHOCK Test fig.lcd-t02-mute 1.The DEMO SONG is played. Perform checking for momentary noise and the like w
22、hen the VOLUME control is operated. 2.Make sure that audio output is muted while the SONG button is pressed. 3.Pressing the TEMPO + / YES button proceeds to the next test. 2.MEMORY Test (MEMORY Test 1) 1.Perform a check of the CPU and flash ROM (program memory). fig.lcd-t03-rom 2.If no problem is fo