sennheiser_sk100g2_sk300g2_sk500g2_sa280205 电路图.pdf
《sennheiser_sk100g2_sk300g2_sk500g2_sa280205 电路图.pdf》由会员分享,可在线阅读,更多相关《sennheiser_sk100g2_sk300g2_sk500g2_sa280205 电路图.pdf(27页珍藏版)》请在收音机爱好者资料库上搜索。
1、SA 280205 Subject to alterations Sennheiser electronic GmbH 1.5V or battery pack BA 2015; 2.4V Nominal voltage _ +2.4VDC Operating voltage _ +1.8VDC to +3.1VDC Switch-off threshold when powered by batteries _ +1.8VDC when powered by BA 2015 accupack_ +2.0VDC Switch-on threshold _ +2.2VDC Current con
2、sumption at nominal voltage_ 170mA with transmitter switched off _ 250A Operating time when powered by batteries or accupack _ 8 hours Battery status indication_ 100%, 70%, 30%, low battery Programming interface _ integrated infrared interface Temperature range _ -10C to +55C Dimensions in mm_ 82 x
3、63 x 23 Weight incl. batteries _ approx. 200g Compliant with Europe_CE 0682 USA _FCC ID: DMOB2EUVL Canada _IC: 2099A-G2SK Japan _R202Y2378511; R202Y2378512; R202B2378531; R202B2378532 SK 100 G2, SK 300 G2, SK 500 G2 6/2702/2005 2.2AF characteristics Audio input LINE / MIC _ jack socket; 3.5mm AF tra
4、nsmission range Microphone_ 40Hz to 18kHz (3dB) Japan: 40Hz to 15kHz (3dB) Line _ 80Hz to 18kHz (3dB) Japan: 80Hz to 15kHz (3dB) AF sensitivity levels _ 0 to -30dB (also refer to input level on page 11) Compander system _ Sennheiser HDX Preemphasis _ HDX-dependent Input impedance Microphone_ 10kW Li
5、ne _ 1MW; parallel 470pF, guitar-optimised Total harmonic distortion (at nominal deviation, 1kHz) _ 0.9% Signal-to-noise ratio (referring to peak deviation) _ 110dB(A) via HDX system Max. input voltage (peak deviation) Microphone_ 1.8Veff (unw) Line _ 2.4Veff SK 100 G2, SK 300 G2, SK 500 G2 02/20057
6、/27 2.3RF characteristics Modulation _ Wideband FM, F8W Number of transmission frequencies (tunable in steps of 25kHz)_ 1440 Frequency ranges in MHz _ 518-554 626-662 740-776 774-810 (Japan) 786-822 834-870 Number of frequency banks with preset channels (presets) SK 100 G2 _ 8 banks with 4 channels
7、each SK 300 G2 _ 8 banks with 8 channels each SK 500 G2 _ 8 banks with max. 20 channels Freely adjustable frequency bank (tunable in steps of 25kHz) SK 100 G2 _ 1 bank, 4 tunable channels SK 300 G2 _ 1 bank, 8 tunable channels SK 500 G2 _ 1 bank, 20 tunable channels Switching bandwidth _ 36MHz Harmo
8、nic emissions _ 1W Spurious wave emissions in the range from 47MHz to 862MHz_ 4nW all other frequencies 1GHz _ 250nW Channel grid _ n x 25kHz Frequency stability within temperature range 10kHz Intermodulation distance (400 kHz) at antenna distance 10cm _ 36dB Nominal deviation_ 24kHz Peak deviation
9、(at 1kHz) 48kHz / Japan: 40kHz RF transmitting power max. at 50W _ 30mW, +0.8dB/-3dB Japan: 10mW, +0.8dB/-3dB Covered bandwidth according to ETSI at -20dBc_ 140kHz at -60dBc_ 200kHz Pilot tone Frequency _ 32.766kHz 7.6Hz Deviation_ 2kHz 0.5kHz Carrier signal-to-noise ratio referring to peak deviatio
10、n within switching bandwidth_ 75dB(A)eff SK 100 G2, SK 300 G2, SK 500 G2 8/2702/2005 3Exploded view 022 004 005 009 013 012 006 011 023 014 008 SK 500 G2) (SK 300 G2, (SK 100 G2) (SK 100 G2) 016 010 007 007 015 017 008 022 002 002 002 002 003 002 001 018 020 019 019 SK 500 G2) (SK 300 G2, SK 100 G2,
11、 SK 300 G2, SK 500 G2 02/20059/27 PosDescription 001Housing complete 002Lens screw 003Clamp 004Cover, LCD 005Cover, LOW BAT 006Cover, infrared 007SK 100 G2: plug right SK 300 G2 / SK 500 G2: double charging contact 008SK 100 G2: plug left SK 300 G2 / SK 500 G2: single charging contact 009Battery cov
12、er 010Axle 011Antenna 012PCB RF 013Battery case 014PCB mainboard 015LC display complet 016Flat cable, 20 pin 017Slide button, black 018Rocker switch, black 019Knob 020Shielding cup 021Label 022Lens screw 023Slottet nut SK 100 G2, SK 300 G2, SK 500 G2 10/2702/2005 4Test and alignment instructions 4.1
13、Measuring and test equipment 1 Spectrum analyzer (up to at least 3GHz) 1 AF signal generator 1 Multimeter 1 Laboratory power supply 1 AF level meter 1 RF power meter 1 RF measuring demodulator 1 Frequency counter 1 PC with service software ew G2) Reference Read out / modified the unit data via infra
14、red adaptor. See also chapter “Reading out / Changing of device data via infrared adaptor” on page 15. 4.2Measuring set-up + Laboratory DC IN AF IN 230.00 MHz AF generator RF OUT Spectrum analyzer AF level meter 230.00 MHz IR MIC LINE GND PC with service software ew G2 1) + Frequency counter Multime
15、ter RF power meter SK x00 G2SK x00 G2 NTC pin Pins of the battery case See“Mainboard, printed circuit board, component side” page 26. Measuring demodulator power supply 1) Note: AF IN: Ground modification of the phone jack: - If you feed in the MIC signal you have to ground the LINE connector of the
16、 phone jack - If you feed in the LINE signal you have to ground the MIC connector of the phone jack. SK 100 G2, SK 300 G2, SK 500 G2 02/200511/27 4.3Special service tools Service set for service software ew G2 (Part-No. 094739) Verwendung im Kapitel: “Reading out / Changing of device data via infrar
17、ed adaptor” on page 15 Infrared adaptor SK 100 G2, SK 300 G2, SK 500 G2 12/2702/2005 4.4Test table Se- quence Type of measure- ment/adjustment Signal inputDevice settingsMesuring point/ test point Required value Remarks 1Visual inspectionVisual inspection 1.1MIC/LINE jack socket Contacts are not twi
18、sted, no hairline cracks at the solder points, no mechanical damage 1.2MUTE slide controlSee 1.1 1.3? / ? button (S204 /S206), SET button (S202), ON/OFF (S208) button Buttons on motherboard spring back See 1.1 1.4Battery compartments See 1.1 1.5Charging contacts (not SK 100 G2) See 1.1 1.6Antenna co
19、ntacts to RF PCB See 1.1 1.7Flat ribbon cables and terminal strips No mechanical damage, locked 2Motherboard: current and voltage measurement Attention The buttons S204, S206, S202, and S208 on the motherboard may be damaged, if you press them using sharp-edged flat or pointed objects (e.g. the tip
20、of a ballpoint pen). Only use objects with end-rounded tips that will not damage the buttons. 2.1Current consumption when transmitter is switched off POWER“ = OFFConnected in series to BK+ battery contact See page 26 220A; typ. 180A Current limita- tion of labora- tory power supply unit: ION = 300mA
21、 2.2Current consumption when in operation Supply +2.4VDC via battery contacts POWER“ = ON; (press button for approx 3 seconds) See 2.1170mALC display is switched off. Test points see page 26 2.3Rated voltageSee 2.2See 2.2BK+ / BK-+2.4VDC 2.4Operating voltageSee 2.2See 2.2 See page 26 BK+ / BK-+1.8VD
22、C to +3.1VDC 2.5DC to DC converter voltage See 2.2See 2.2TP224/ GND+5,3VDC to +5,7VDC 2.6Switch-on/switch-off thresholds 2.6.1Switch-on threshold when powered by battery See 2.2See 2.2See 2.5+1.8VDC 2.6.2Switch-on threshold when powered by accupack See 2.2; SK OFF: Connect the NTC contact to ground
23、via isolated wire, then switch on SK again: See page 26 See 2.2See 2.5+2.2VDC 2.6.3Switch-off threshold when powered by battery See 2.2See 2.2See 2.5+1.8VDCLED LOW BAT has to flash 2.6.4Switch-off threshold when powered by accupack See 2.6.2See 2.2See 2.5+2.0VDCLED LOW BAT has to flash SK 100 G2, SK