studer OnAir1000_V403_Op 电路图.pdf
《studer OnAir1000_V403_Op 电路图.pdf》由会员分享,可在线阅读,更多相关《studer OnAir1000_V403_Op 电路图.pdf(164页珍藏版)》请在收音机爱好者资料库上搜索。
1、Studer OnAir 1000 Digital Mixing Console SW Version 4.0/4.03 Operating Instructions RadioFans.CN 收音机爱 好者资料库 Studer is a registered trade mark of Studer Professional Audio GmbH, Regensdorf Prepared and edited byCopyright by Studer Professional Audio GmbH Studer Professional Audio GmbHPrinted in Switz
2、erland Technical Documentation Order no. 10.27.4872 (Ed. 0405) Althardstrasse 30 CH-8105 Regensdorf Switzerland http:/www.studer.chSubject to change RadioFans.CN 收音机爱 好者资料库 Safety Information I ASafety Information To reduce the risk of electric shock, do not remove covers. No user- serviceable parts
3、 inside. Refer servicing to qualified service personnel (i.e., persons having appropriate technical training and experience neces- sary to be aware of hazards to which they are exposed in performing a repair action, and of measures to minimize the danger of themselves). This symbol alerts the user t
4、o the presence of un-insulated dangerous voltage within the equipment that may be of sufficient magnitude to con- stitute a risk of electric shock to a person. This symbol alerts the user to important instructions for operating and maintenance in this documentation. Assemblies or sub-assemblies of t
5、his product can contain opto-electronic devices. As long as these devices comply with Class I of laser or LED products according to EN 60825-1:1994, they will not be expressly marked on the product. If a special design should be covered by a higher class of this standard, the device concerned will b
6、e marked directly on the assembly or sub-assembly in accordance with the above standard. A1First Aid In Case of Electric Shock:Separate the person as quickly as possible from the electric power source: By switching off the equipment, By unplugging or disconnecting the mains cable, or By pushing the
7、person away from the power source, using dry, insulating material (such as wood or plastic). After having suffered an electric shock, always consult a doctor. Warning!Do not touch the person or his clothing before the power is turned off, otherwise you stand the risk of suffering an electric shock a
8、s well! If the Person is Unconscious: Lay the person down Turn him to one side Check the pulse Reanimate the person if respiration is poor Call for a doctor immediately. CLASS I LASER PRODUCT CLASS I LED PRODUCT RadioFans.CN 收音机爱 好者资料库 Installation/Maintenance/ESD II BGeneral Installation Instructio
9、ns Please consider besides these general instructions also any product-specific instructions in the “Installation” chapter of this manual. B1Unpacking Check the equipment for any transport damage. If the unit is mechanically damaged, if liquids have been spilled or if objects have fallen into the un
10、it, it must not be connected to the AC power outlet, or it must be immediately disconnected by unplugging the power cable. Repair must only be per- formed by trained personnel in accordance with the applicable regulations. B2Installation Site Install the unit in a place where the following condition
11、s are met: The temperature and the relative humidity of the environment must be within the specified limits during operation of the unit. Relevant values are the ones at the air inlets of the unit. Condensation must be avoided. If the unit is installed in a location with large variation of ambient t
12、emperature (e.g. in an OB-van), appropriate precautions must be taken before and after operation (for details on this subject, refer to Appendix 1). Unobstructed air flow is essential for proper operation. Air vents of the unit are a functional part of the design and must not be blocked in any way d
13、uring operation (e.g. by objects placed upon them, placement of the unit on a soft surface, or installation of the unit within a rack or piece of furniture). The unit must not be heated up by external sources of heat radiation (sunlight, spot lights). B3Earthing and Power Supply Earthing of units wi
14、th mains supply (class I equipment) is performed via the protective earth (PE) conductor integrated in the mains cable. Units with battery operation ( 60 V, class III equipment) must be earthed sepa- rately. Earthing the unit is one of the measures for protection against electrical shock hazard (dan
15、gerous body currents). Hazardous voltage may not only be caused by a defective power supply insulation, but may also be intro- duced by the connected audio or control cables. If the unit is installed with one or several external connections, its earthing must be provided during operation as well as
16、while the unit is not operated. If the earthing connection can be interrupted, for example, by unplugging the mains plug of an external power supply unit, an additional, permanent earthing connection must be installed using the provided earth terminal. Avoid ground loops (hum loops) by keeping the l
17、oop surface as small as possible (by consequently guiding the earth conductors in a narrow, paral- lel way), and reduce the noise current flowing through the loop by inserting an additional impedance (common-mode choke). ESD/Repair III Class I Equipment (Mains Operation) Should the equipment be deli
18、vered without a matching mains cable, the latter has to be prepared by a trained person using the attached female plug (IEC320/C13 or IEC320/C19) with respect to the applicable regulations in your country. Before connecting the equipment to the AC power outlet, check that the local line voltage matc
19、hes the equipment rating (voltage, frequency) within the admissible tolerance. The equipment fuses must be rated in accordance with the specifications on the equipment. Equipment supplied with a 3-pole appliance inlet (protection conforming to class I equipment) must be connected to a 3-pole AC powe
20、r outlet so that the equipment cabinet is connected to the protective earth. For information on mains cable strain relief please refer to Appendix 2. Female Plugs (IEC320), Front-Side View: European Standard (CENELEC) North American Standard (NAS) BrownL (Live)Black BlueN (Neutral)White Green/Yellow
21、PE (Protective Earth)Green (or Green/Yellow) Class III Equipment (Battery Operation up to 60 VDC) Equipment of this protection class must be earthed using the provided earth terminal, if one or more external signals are connected to the unit (see ex- planation at the beginning of this paragraph). B4
22、Electromagnetic Compatibility (EMC) The unit conforms to the protection requirements relevant to electromag- netic phenomena that are listed in guidelines 89/336/EC and FCC, part 15. The electromagnetic interference generated by the unit is limited in such a way that other equipment and systems can
23、be operated normally. The unit is adequately protected against electromagnetic interference so that it can operate properly. The unit has been tested and conforms to the EMC standards of the speci- fied electromagnetic environment, as listed in the following declaration. The limits of these standard
24、s ensure protection of the environment and cor- responding noise immunity of the equipment with appropriate probability. However, a professional installation and integration within the system are imperative prerequisites for operation without EMC problems. For this purpose, the following measures mu
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- studer OnAir1000_V403_Op 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


