Yamaha DG60FX-112 Service Manual 电路图.pdf
《Yamaha DG60FX-112 Service Manual 电路图.pdf》由会员分享,可在线阅读,更多相关《Yamaha DG60FX-112 Service Manual 电路图.pdf(49页珍藏版)》请在收音机爱好者资料库上搜索。
1、DG60FX-112 1 SERVICE MANUAL GA 011540 20001101-75000 1.552K-448 I.T Printed in Japan 2000.11 HAMAMATSU, JAPAN GUITAR AMPLIFIER CONTENTS SPECIFICATIONS. 3/4 PANEL LAYOUT. 5 CIRCUIT BOARD LAYOUT. 7 BLOCK DIAGRAM. 8 WIRING. 10 DISASSEMBLY PROCEDURE. 11 LSI PIN DESCRIPTION. 15 IC BLOCK DIAGRAM. 18 CIRCU
2、IT BOARDS. 20 TEST PROGRAM. 30 ERROR MESSAGES. 33 IDLING ADJUSTMENT. 33 MIDI IMPLEMENTATION CHART . 34 PARTS LIST OVERALL CIRCUIT DIAGRAM This document is printed on chlorine free (ECF) paper with soy ink. RadioFans.CN 收音机爱 好者资料库 DG60FX-112 2 2 IMPORTANT NOTICE This manual has been provided for the
3、use of authorized Yamaha Retailers and their service personnel. It has been assumed that basic service procedures inherent to the industry, and more specifically Yamaha Products, are already known and under- stood by the users, and have therefore not been restated. WARNING :Failure to follow appropr
4、iate service and safety procedures when servicing this product may result in per- sonal injury, destruction of expensive components and failure of the product to perform as specified. For these reasons, we advise all Yamaha product owners that all service required should be performed by an authorize
5、d Yamaha Retailer or the appointed service representative. IMPORTANT :This presentation or sale of this manual to any individual or firm does not constitute authorization certifi- cation, recognition of any applicable technical capabilities, or establish a principal-agent relationship of any form. T
6、he data provided is belived to be accurate and applicable to the unit(s) indicated on the cover. The research engineering, and service departments of Yamaha are continually striving to improve Yamaha products. Modifications are, therefore, inevitable and changes in specification are subject to chang
7、e without notice or obligation to retrofit. Should any discrepancy appear to exist, please contact the distributors Service Division. WARNING :Static discharges can destroy expensive components. Discharge any static electricity your body may have accumulated by grounding yourself to the ground bus i
8、n the unit (heavy gauge black wires connect to this bus.) IMPORTANT :Turn the unit OFF during disassembly and parts replacement. Recheck all work before you apply power to the unit. WARNING: CHEMICAL CONTENT NOTICE! The solder used in the production of this product contains LEAD. In addition, other
9、electrical/electronic and/or plastic (Where applicable) components may also contain traces of chemicals found by the California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive harm. DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLAST
10、IC COMPONENTS IN YOUR MOUTH FOR ANY REASON WHAT SO EVER! Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose eyes to solder/flux vapor! If you come in contact with solder or components located inside the enclosure of this product, w
11、ash your hands before handling food. WARNING Components having special characteristics are marked and must be replaced with parts having specification equal to those originally installed. LITHIUM BATTERY HANDLING This product uses a lithium battery for memory back-up. WARNING :Lithium batteries are
12、dangerous because they can be exploded by improper handling. Observe the following pre- cautions when handling or replacing lithium batteries. Leave lithium battery replacement to qualified service personnel. Always replace with batteries of the same type. When installing on the PC board by solderin
13、g, solder using the connection terminals provided on the battery cells. Never solder directly to the cells. Perform the soldering as quickly as possible. Never reverse the battery polarities when installing. Do not short the batteries. Do not attempt to recharge these batteries. Do not disasemble th
14、e batteries. Never heat batteries or throw them into fire. ADVARSEL! Lithiumbatteri-Eksplosionsfare ved fejlagtig handtering. Udskiftning ma kun ske med batteri af samme fabrikat og type. lever det brugte batteri tilbage til leverandren. VARNING Explosionsfara vid felaktigt batteribyte. Anvand samma
15、 batterityp eller en ekvivalent typ som rekommenderas av apparattillverkaren. Kassera anvant batteri enligt fabrikantens instruktion. VAROITUS Paristo voi rajahtaa, jos se on virheellisesti asennettu. Vaihda paristo ainoastaan laitevalmistajan suosittelemaan tyyppiiin. Havita kaytetty paristo valmis
16、tajan ohjeiden mukaisesti. The following information complies with Dutch official Gazette 1995. 45; ESSENTIALS OF ORDER ON THE COLLECTION OF BATTERIES. Please refer to the diassembly procedure for the removal of Back-up Battery. Leest u voor het verwijderen van de backup batterij deze beschrijving.
17、2 RadioFans.CN 收音机爱 好者资料库 DG60FX-112 3 SPECIFICATIONS Digital Section Full Digital Signal Processing 8 Channel Preamp Digital Effects Compressor Chorus, Flanger, Phaser, Rotary Speaker, Tremolo Digital Delay, Tape Echo Spring Reverb, Hall Reverb, Plate Reverb Tap Tempo Function (Delay Time) Speaker
18、Simulator (16 Types) External Controller Function (EXP Pedal/MIDI):8 Controllers/ Parameters Wah Function Tuner Function (Chromatic, Auto) Analog Section 60 W Solid State Power Amp 30 cm Speaker (EMINENCE) x 1 MIDI Functions Receive: Program Change (Program Change Table can be created), Control Chan
19、ge, Bulk In Transmit: Program Change, Control Change, Bulk Out, Merge Out Controller Switch Top Panel Push Switch x17 UP , DOWN, MANUAL, UTILITY, STORE, COMP, CHORUS, FLANGER, PHASER, ROTARY, TREMOLO, DELAY, TAPE ECHO, SPRING, HALL, PLATE, SP. SIM Knob x15 AMP SELECT, GAIN, MASTER, TREBLE, MIDDLE, B
20、ASS, PRESENCE, COMP, SPEED, DEPTH, TIME, FEEDBACK, LEVEL, REVERB, OUTPUT Rear Panel Push Switch x1 POWER Display 7 Segment LED (3 digit) x1 Push Switch LED x17 Connections/Jacks INPUT HIGH, LOW: Standard Monaural Phone Jack LINE OUT L/MONO, R: Standard Monaural Phone Jack PHONES: Standard Stereo Pho
21、ne Jack POWER AMP IN: Standard Monaural Phone Jack Foot Switch Unit Terminal: 13 pin DIN DIGITAL OUT: COAXIAL MIDI IN, MIDI OUT: 5 pin DIN A/D Converter 20 bit + 3 bit Floating D/A Converter 20 bit Sampling Frequency 48 kHz Memory Allocations Preset: 90 User: 90 Input Level/Impedance INPUT HIGH: -25
22、dBm/1M ohm INPUT LOW: -15dBm/1M ohm POWER AMP IN: 0 dBm/100k ohm Output Level/Impedance LINE OUT L/MONO, R: -3dBm/2.3k ohm PHONES: 0dBm/47 ohm (47ohm load) SPEAKER: 60W RMS/8 ohm Power U.S. and Canadian models : 120V, 60Hz General model : 230V, 50Hz Power Consumption 70 W Dimensions (WxHxD) 513 x 49
23、1 x 291 mm (20.2” x 19.3” x 11.5”) Weight 17 kg (37 lbs 8 oz) Accessories Foot Switch Unit Foot Switch Special Cable Owners Manual Patch List Foot Switch Unit Footswitch x4 (1, 2, 3, BANK) LED x6 (1, 2, 3, BANK x3) Connections/Jacks EXP. PEDAL: Standard Stereo Phone Jack Connects main unit and foot
24、switch: 13 pin DIN Dimensions (WxHxD) : 280 x55 x108 mm (11.0” x 2.2” x 4.3”) Weight : 930 g (2 lbs 1 oz) RadioFans.CN 收音机爱 好者资料库 DG60FX-112 4 DG60FX-112 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 PANEL LAYOUT Input Jacks (INPUT HIGH, LOW) Peak Indicator Amp Select Switch (L
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Yamaha DG60FX-112 Service Manual 电路图 DG60FX 112
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf
301.rar
danita 240 FM.jpg