Bogen Mct-1 Control Center 电路图.pdf
《Bogen Mct-1 Control Center 电路图.pdf》由会员分享,可在线阅读,更多相关《Bogen Mct-1 Control Center 电路图.pdf(14页珍藏版)》请在收音机爱好者资料库上搜索。
1、BOGEN A DIVISION OF LEAR SIEGLER, INC. MCT-1 MODELS 15-1, SERIES 15 C o n t r o l C+- 15T-1,15-2,15-3 DESCRIPTION The Bogen Series 15-1 Centralized School Sound System is designed to serve up to 50 rooms. It incorpo- rates one Model MCT-1 Control Center and either one or two Model SBS-25 Switchbanks
2、, and is housed in a desk-top consolette. The Series 15T- 1 accommodates up to 25 rooms and includes one Control Center, one Switchbank and one Model TP-160B AM/FM Tuner housed in a desk-top consolette. The Series 15-2 consists of one Control Center, one or two Switchbanks, one AM/FM Tuner and one B
3、SR 3-speed record changer. It is housed in a desk-top, dual consolette and serves up to 50 rooms. The Series 15-3 consists of one Control Center, one or two Switchbanks, one AM/FM Tuner and one 3-speed record changer. It can accommodate up to 50 rooms and is operated from a sturdy free-standing cons
4、ole. Each system has one 35-watt program channel and an independent 4-watt intercom channel. The program channel has two low-impedance microphone inputs which can be used balanced or unbalanced. It also has inputs for radio, phono and tape program sources and a fader control to select either radio o
5、r phono-tape. The selected program may be used alone or may be mixed with the microphone program. The MCT-1 control panel has a loudspeaker which serves as both a program monitor speaker and an inter- com transmitter/receiver. By means of the intercom channel, the operator may hold a two-way convers
6、ation with occupants of any room without disturbing the pro- gram being transmitted to other rooms. If desired, the intercom channel also may be used to permit the op- erator to monitor any selected room through its room speaker. Model 15-2 In addition to the control panel, each Series 15 con- solet
7、te or console has one or two switchbanks contain- ing the individual room selector switches. In the stan- dard system, these are 3-position lever switches used to connect each room speaker to either the program (A) channel or the intercom (C) channel, or to disconnect the speaker from the system (Sy
8、stems with optional light-annunciator call circuit have four-position lever switches). The units have an Emergency mode of opera- tion which overrides these selector switches. When operating in Emergency, the operator can transmit from the control panel speaker to all room speakers, regard- less of
9、the settings of the room selector switches or of other program inputs to the speakers. The Emergency function operates whether the power switch is on or off. INSTALLATION UNPACKING Inspect the shipping container and unit for indica- tions of improper handling. The unit was carefully checked before l
10、eaving the factory. If the unit has been damaged, make an immediate claim to the dealer or dis- tributor from whom it was purchased. If the unit was shipped to you, notify the transport company without delay and place your claim. Printed in USA 8005 CENTRALIZED SCHOOL SOUND SYSTEM 54-5665-04 RadioFa
11、ns.CN 收音机爱 好者资料库 LOCATION OF CONSOLE/CONSOLETTE Where possible locate the console centrally, relative to the rooms being served, in order to minimize the length of speaker cables. The rear of the unit must remain accessible for maintenance and for changing in- put and output connections. It is advis
12、able that the unit be oriented in such a manner that the operator, program director and other interested parties are able to observe the controls at all times. Provide adequate lighting and ventilation. Do not locate the unit close to heat sources, such as radiators and warm-air ducts, or against a
13、wall which prevents proper ventilation. The Series 15-1 and 15T-1 consolettes are 21” (54 cm.) wide x 16” (40.6 cm.) high x 16” deep. The Series 15-2 consolette is 40” (102.9 cm.) wide x 16” high x 16” deep. The Series 15-3 console is 22” (55.9 cm.) wide x 46” (116.8 cm.) high x 31” (78.7 cm.) deep.
14、 POWER Connect the 3-wire cord with ground to a 105-125V, 50/60 Hz source. Make certain that the ground terminal of the power receptacle connects to earth ground. Two 50W AC power receptacles are provided on the rear panel for a tuner, automatic record changer or aux- iliary equipment. Line voltage
15、is applied to these com- ponents when the consolette or console power switch is on. Plug AC line cords into appropriate receptacle. INPUT CONNECTIONS MICROPHONE INPUTS. Two terminal strips on the rear of the MCT-1 provide for two low impedance balanced or unbalanced microphone inputs. Two- conductor
16、 shielded microphone cable should be used (Bogen #l008 or equivalent). Connect shield to terminal 1. TUNER/PHONO-TAPE INPUTS. Two jacks accept single-conductor shielded cable. TAPE RECORDER/BOOSTER AMP INPUT. Ac- cepts a two-conductor shielded cable (Bogen BB 8450 or equivalent). INTERCOM CALL-IN LI
17、NE. Connect parallel lines from station call-in switches with 2-conductor shielded cable. Connect shield to terminal 3. SWITCHBANK CONNECTION. Eleven-pin plug connects three shielded pairs plus annunciator wire from a switchbank. Also accommodates three lines for optional telephone system. TIME CLOC
18、K INPUT. Terminal strip connects a single-circuit time clock, closing contacts to activate the optional Model SST-l Module. GENERAL WIRING RUNNING CABLES WIRES. Class II wiring may be used for all audio and annunciator lines. Make certain to properly support cables to prevent sagging or strain. Keep
19、 wires clear of objects which would subject them to heat, friction, or other abuse. Use No. 20 AWG shielded pairs with insulated outer jacket (Bogen BB-8450, or equivalent) for speaker lines. Annunciator lines require a third wire, which usually is No. 22 AWG insulated wire with red insulation (Beld
20、en 8937, or equivalent). The number and types of wires running from each room to the consolette and running inside the classroom depend upon the type of speaker operation required. Consult Table I for the wires re- quired in your particular system. TABLE I. CABLE RUNNING CHART FOR SERIES 15 Wires fr
21、om Room to Consolette Wires From Room Switch to Room Speaker Type of Classroom Switch or Device Shielded Pair No. 22 AWG Used with Speaker Shielded Pair (Jacketed) Single Conductor (Jacketed) Refer to (Bogen BB-8450) Figure (Belden 8937) (Bogen BB-8450) None (Speaker Only) 1 0 0 l Call (Model CA-l0)
22、 1 1 1 l Call/Privacy (Model CA-l 1) 1 1 1 10 Voice Call-In, Non-Private 2* 0 1 2, 7 (Model CA13) *Alternate method: Run two cables from room nearest consolette and one cable from each remaining room. Run one cable in a loop or branch circuit connecting all room switches. -2- RadioFans.CN 收音机爱 好者资料库
23、 OUTLET BOXES. Where flush-mounting switches are used, single-gang outlet boxes will be installed. In installing such boxes, make certain to place them in a location that permits personnel to operate the switch while communicating via the room speaker. The normal height (above the finished floor) fo
24、r room switches is approximately four feet, while speakers are normally placed at a height of about seven and one-half feet. SOLDERING INSTRUCTIONS SOLDER. Do not use acid-core solder or acid paste. Make all solder connections with standard 60/40 resin- core radio solder. Do not apply excessive heat