Rauland Mca100 Series Master Control Panels 电路图.pdf
《Rauland Mca100 Series Master Control Panels 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Mca100 Series Master Control Panels 电路图.pdf(35页珍藏版)》请在收音机爱好者资料库上搜索。
1、KI-1152-B DIRECTOR SERIES MASTER CONTROL PANELS MODELS MCAlOO, MCAlOOA, MCBlOO AUXILIARY -65 dB Tone Control Range: 10 dB at 100 Hz and 10 kHz Compression Amplifier: 20 dB range(less than 2% distortion) Program Inputs: MICROPHONE, three; balanced 150 ohm; 0.3 mV sensitivity AUXILIARY, four;unbalance
2、d 250 k-ohm; 0.25 V sensitivity BRIDGING (EXPD), one; unbalanced 10 k-ohm; 0.25 V sensitivity Power Requirements: 28 V dc,and 6 V ac (for switch lamps) Lamp Life Expectancy: 50,000 hours Unit Size: 19 panel x 3 high x 7% deep SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE PAGE 2 RadioFans.CN
3、收音机爱 好者资料库 1. DESCRIPTION 1.1 General The Model MCAlOO and MCBlOO Master Control Panels provide the program channels for the Rauland DIRECTOR Series School Sound/ Communications Systems. Each master control panel provides one program channel which operates independently of the other program channel.
4、 This permits separate selection, audio processing, monitor- ing, and distribution of the two program channels. The Model MCAlOO serves as the main panel and is designated the GREEN A CHANNEL. The Model MCBlOO serves as the secondary panel and is designated the BLUE B CHANNEL. The two Models differ
5、only in that the Model MCAlOO includes EMERGENCY and ALL-CALL switches, with corresponding program priority switching and audio processing circuits. The panel color designations provide the means for simplified equipment operation. All associated equipment panels are color coordinated to these maste
6、r control panels. The use of color coordinated equipment panels, illuminated switches,and step-by-step operating instructions screened on the equipment panels virtually eliminates operator error. 1.2 Features These master control panels provide the following features: -State-of-the-art circuitry usi
7、ng integrated circuits for logic switching and some audio amplification stages. This minimizes power consumption, increases reliability,and reduces maintenance costs. -Selection of seven program input sources; three MICROPHONES and four OTHER PROGRAM SOURCES (auxiliary inputs). The microphone inputs
8、 are balanced and are for low-impedance microphones. One microphone input is for the console operator and the other two are for remotely located microphones. The auxiliary inputs are high-impedance and are for in- puts from an AM/FM tuner, record changer, tape deck, etc. -Shared program source opera
9、tion may be used allowing loop-through distribution of the same program through both the Green A CHANNEL and BLUEB CHANNEL. Any microphone input to the Model MCAlOO may be looped-through to the Model MCBlOO. Any auxiliary program source input to the Model MCBlOO may be looped-through to the Model MC
10、AlOO. -An EXPD (expanded) or bridging program input allows four additional microphones to be used. The optional Rauland PRO 204 Microphone Input Expander is required when this mode of operation is used. (See Paragraph 2.2.3 for details.) -Remote control of the program volume level and/or remote sele
11、ction Of program precedence. Precedence selection mutes respective input (either the microphone or the auxiliary source) giving program precedence to the other input. Remote control of either functionrequires the Rauland Model 47RCA Remote Control Adapter. (See Paragraph 2.2.1 for details!. PAGE 3 o
12、f 26 - Compression amplifier with 20 dB dynamic range assures optimum operation under widely varying program input levels. This eliminates the need of having separate volume controls for each of the seven inputs and their burdensome readjustment with each change of input level. - TREBLE and BASS ton
13、e controls with full adjustment range allow the response characteristic of the audio amplification circuits to be changed,matching the sound characteristics of the classrooms. - Monitor speaker with level control allows the selected program input to be heard prior to and during its distribution to t
14、he classrooms. - Program output level and impedance compatible with any Rauland SAX, TAX or DX Series Amplifiers providing between 60 and 250 watts of sound power for distributions to the classrooms. Any Rauland room selector switch panel may be used for program distribution to 25 rooms. Addit- iona
15、l switch panels may be added for distribution up to 200 rooms per master control panel. - ALL-CALL switch provides program distribution to all classrooms in the sound system,regardless of prior room selections made at the room selector switch panel (s ).TO ROOMS SELECTED switch provides program dist
16、ribution only to those classrooms individually selected at the room selector switch panel(s) for the respective program channel. - EMERGENCY switch interrupts in-progress program distribution allowing immediate distribution of the emergency announcement to all classrooms in the sound system. Switche
17、s illuminate when depressed (engaged) indicating the selected - input for the program source and the type of room distribution. This takes the guesswork out of determining what was selected as frequently happens when conventional switches are used. - - System priority (take-over control) is readily
18、established using jumper options. Different levels of priority may be assigned to: (1) an emergency announcement from the equipment operator; (2) the tone signaling output from the optional multi-tone generator; and (3) an administrative all-call, in systems using the optional administrative communi
19、cation stations. Priority is always given to the highest level when two or three priorities occur simultaneously. - Three OUTPUT LEVEL indicators provide continuous visual monitoring of therelativeaudio output level routed to the associated high power amplifier. This allows the equipment operator to
20、 easily determine if the output is proper, eliminating the need for reading meters. Equipment operators seldom understand how to read meter scales or how to interpret the reading observed. - Direct accessibility to input source level controls, tone adjustment controls,phono-jacks and screw terminals
21、; these items are mounted on the rear of the chassis. PAGE 4 of 26 2. ACCESSORIES 2.1 Required 2.1.1 Rauland Model - - - - - - - 28 V dc power source PSX29A DC Power Supply/AC Control - Provides the - - - - - - - - - - - for theDIRECTOR Series School Sound/Communication: System. Includes six relay-c
22、ontrolled 120 V ac power outlets for plug-in of associated equipment requiring ac power. This dc power supply/ac control is not required if the Rauland Model SAX60 or SAX100 All-Silicon Solid-State Power Amplifier is provided with the system, as these amplifiers include a 28 V dc power supply. 2.1.2
23、 Rauland Model LP-0413 Transformer - - - - - - - - - - - - - - - - Provides the 6.3 V ac power source for theDIRECTOR Series School Sound/Communications System. All panel-mounted pushbutton switches use 6.3 V ac indicator lamps for long life expectancy. 2.1.3 Rauland Model MCRlOO Master Control Rela
24、x - Provides program source and intercom buss-gathering for routing ALL-CALL or EMERGENCY announcements or signaling tones to all rooms simultaneously. 2.2 Optional 2.2.1 Rauland Model 47RCA Remote Control Adapter - Permits remote control of the program volume,and/or remote precedence selection of t
- 配套讲稿: