Bogen Mcp35 Master Control Panel 电路图.pdf
《Bogen Mcp35 Master Control Panel 电路图.pdf》由会员分享,可在线阅读,更多相关《Bogen Mcp35 Master Control Panel 电路图.pdf(12页珍藏版)》请在收音机爱好者资料库上搜索。
1、BOGEN A LEAR SIEGLER COMPANY MCP35 MASTER CONTROL PANEL PI-35/SI-35 SYSTEMS INSTALLATION AND SERVICE MANUAL IT IS RECOMMENDED THAT THIS ENTIRE MANUAL BE CAREFULLY READ BEFORE ATTEMPTING TO INSTALL THE MASTER CONTROL PANEL OR ANY OF THE SYSTEMS COVERED HEREIN. PI-35 TABLE OF CONTENTS SECTION ONE: MCP
2、35 MASTER CONTROL PANEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . TECHNICAL SPECIFICATIONS. DESCRIPTION. INSTALLATION. Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power and Grounding. Auxiliary Power. Line-Matching Transformers. Input Connections. O
3、utput Connections. ADJUSTMENTS AND MODIFICATIONS. Gain Adjustments. Defeating MIC 1 to CONSOLE MIC Configuration ASSOCIATED EQUIPMENT. Time Tone/Telco Page. External Booster Amplifier. SCHEMATIC DIAGRAMS. MCP35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SBA225. . . . . . .
4、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 . 2 .4 . 4 .4 . 4 .4 4 . 4 . 5 5 . 5 . 5 . 5 . 5 6 7 SECTION TWO: Multi-Graphic PI-35 SYSTEM/ SI-35 SYSTEM. . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 TECHNICAL SPECIFICATIONS DESCRIPTION . . . . . . . . . . . . . .
5、 ASSOCIATED EQUIPMENT . . . . Switchbanks. Switchbank Modules. . . . . . . . . . . . . SCR25 Call-In Module . . . . . . . . TZMA Time Zone Module . . . Staff Station Equipment . . . . . Call/Emergency Switches . . . . APPENDIX. GENERAL WIRING. STATION WIRING. CONTROL CENTER WIRING. MAINTENANCE. Boge
6、n Service. Replacing Components. Replacement Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 . . . 8 . . 8 . . . 8 . . . 9 . . 9 . . 9 . . 9 . . . 9 . .a-l . . .a-l . . .a-l . .a-l . .a-l . .a-l . . .a-3 . . .a-3 1986 Lear Siegler Inc. Pri
7、nted in U.S.A.8610 54-5830-01 RadioFans.CN 收音机爱 好者资料库 SECTION ONE: MCP35 Rated Output: Frequency Response: Distortion: Inputs: output: Input Sensitivity (for rated output): Power Requirements (120VAC, 6OHz): Dimensions: Weight: Controls Hi-Z unbalanced AUX input; Hi-Z booster input Balanced 25VCT li
8、ne Microphone-300 V Auxiliary- 1 OOmV 1OOW maximum 19”W x 3-1/2”H x 10”D (48.2 x 8.9 x 25.4cm) Approximately 10 lbs. (4.8 kg) Input Selector Pushbuttons-MIC 1, MIC 2, AUX Level Controls-MONITOR/LISTEN, PROGRAM (Front Panel) Gain: AUX, MIC 1, MIC 2, LISTEN, TALK, EMERGENCY PAGE (Rear Panel, screwdriv
9、er-adjustable) Distribution Switches-ALL ROOMS, EMERGENCY PAGE Indicators-LED LEVEL Indicators Bogen Sand with color-coded guides for PROGRAM, INTERCOM, and EMERGENCY PAGE DESCRIPTION Bogen Model MCP35 Master Control Panel provides facilities for instantaneous two-way communication and distribution
10、of paging, background music, or other program material for up to 75 speaker-equipped stations. A built-in 8-watt intercom ampli- fier features a frequency response shaped for maximum intel- ligibility. A separate 35-watt program amplifier ensures that program material and/or emergency announcements
11、are clear- ly heard and easily understood. The front panel features step- by-step instructions and color-coded indicia which permit even first-time users to easily operate the system: the intercom chan- nel guide indicia color-code is green, the program channel guide indicia color-code is amber, and
12、 the emergency page guide in- dicia color-code is red. Input facilities are provided for external microphones, tuner, cassette player, or other background music source. Level con- trols and audible and visual monitoring of program material are provided. Distribution is accomplished by simple pushbut
13、- ton program selection and by following color-coded indicia. Emergency announcements to all locations take precedence over program distribution and are accomplished with a single pushbutton selection. Provision is included for time signalling, telephone paging, and for connection to a booster ampli
14、fier. The MCP35 Master Control Panel is used in conjunction with Bogen Room Selector and Annunciator Panels to direct inter- com, or program, to selected staff stations. Replies are heard through the front panel speaker of the MCP35. Calls from staff locations are initiated through the use of call-i
15、n switches and are announced by light and tone annunciation. Provision for voice call-in is included. Model MCP35 control panel permits the user to: . . . . 2 establish direct two-way voice communication between the control panel and any speaker-equipped location via a switchbank and the press-to-ta
16、lk/release-to-listen pushbut- ton, while maintaining simultaneous distribution of pro- gram material to any other speaker-equipped location. disseminate voice announcements to any individual, group, or all speaker-equipped locations. disseminate program material to any individual, group, or all spea
17、ker-equipped locations. easily make program source selection by pressing the appro- priately labelled pushbutton corresponding to input from RadioFans.CN 收音机爱 好者资料库 INSTALLATION LINE-MATCHING TRANSFORMERS NOTE Refer to Appendix for wiring information. UNPACKING Your unit was carefully checked before
18、 leaving the factory; in- spect the shipping container and the unit closely for improper handling. If the unit has been damaged, make an immediate claim to the distributor from whom it was purchased. If the unit was shipped directly to you, save all shipping material, notify the carrier immediately
19、and place your claim. POWER AND GROUNDING The MCP35 Master Control Panel operates from a 12OVAC, 60Hz source and consumes no more than 100 watts. An AC line cord, terminated in a three-prong plug, is provided. The line cord should be plugged into a three-wire grounded outlet pro- viding a nominal 12
20、OVAC, 6OHz power source. It is important to ground the unit; therefore, if a three-wire outlet is not available, an adapter such as Leviton No. 5017 should be used to convert a standard two-wire outlet for use with three-wire plugs. The adapter is provided with a grounding pigtail which should be co
21、nnected to the screw holding the wall plate to the receptacle. In some areas, the wall plate screw is not grounded. In this case it is necessary to connect a grounding wire from the EARTH GND terminal on the rear chassis of the MCP35 to a water or steam pipe. AUXILIARY POWER An 840-watt, three-wire
22、grounded outlet is provided on the rear panel to supply power to accessory equipment. Auxiliary equipment connected to this outlet will be grounded, provided the Master Control Panel line cord has been properly grounded. 8 OHMS I SECONDARY L-J 25 VOLTS PRIMARY COM 4 2 I 1 7 2 $, WATTS The MCP35 Mast
23、er Control Panel is designed for 25-volt con- stant voltage distribution systems. All system loudspeakers must be provided with line-matching transformers. CAUTION Speakers and transformers must be properly matched with respect to power requirements. INPUT CONNECTIONS MICROPHONE INPUTS-terminal stri
24、ps on the rear of the MCP35 provide for two low-impedance balanced or unbalanc- ed microphone inputs. Two-conductor shielded microphone cable should be used. TUNER/PHONO/TAPE INPUTS-two AUX jacks accept single-conductor shielded cable. TAPE RECORDER/BOOSTER AMP INPUT-accepts a two-conductor shielded