Rauland 2401Cc Oscillator 电路图.pdf
《Rauland 2401Cc Oscillator 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland 2401Cc Oscillator 电路图.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、Crystal-Controlled Installation KI-1615 RAULAND-BORG CORPORATION l 3450 West Oakton Street, Skokie, Illinois 60076-2951 l (708) 679-0900 Description 2401CC is provided with the hardware needed to mount it nearby and connect it to the 2490. The Rauland Model 2401CC module may be added to any 2424 or
2、2490 Master Clock or 2480 Programmer in Unpacking or for wall-mount installations (2424WN), construe “top” as “back,” and “back” as “bottom.” Step 1. Remove the five screws securing the back panel, then set them and the panel aside. Step 2. Locate Terminals T3 and T4 on the Zone Relay Module (ZRM) b
3、oard (as you face the back, they are about one-half inch behind the leftmost screw terminal, 1A). Using a screwdriver or a similar tool, short together T3 and T4, taking care not to short anything else. LED Dl3, which is half an inch further in, should light: this confirms that 01969 RAULAND-BORG CO
4、RPORATlON l Printed in U.S.A. Orig. 6/89. Relay RY9 is unlatched and, hence, that the battery is disconnected. Note: An earlier model, 2424B, has a separate battery- disconnect module, whose terminals are labeled “Tl” and “T2,” and whose LED, labeled “D4,” is right next to them. Step 3. Unplug the m
5、aster clock to disconnect the AC power. Step 4. Remove the screw securing the vertical support bracket at the back of the printed circuit boards, then set the screw and the bracket aside. Find Terminal Z on the right side of the ZRM board. If it has a wire coming from the DPU board, disconnect that
6、wire. Page 1 of 4 RadioFans.CN 收音机爱 好者资料库 2401CC Crystal-Controller Oscillator Step 5. Pull out the Display Processing Unit (DPU) board, set it on a suitable work surface, and orient it so that you can read most of the screening. Note: Alternatively, you may find it easier to remove the top cover, w
7、hich will enable you to work on the DPU board without removing it. Step 6. Cut zener diode D1 (it is near the left side of the DPU board, to the left of IC2 and to the immediate right of tantalum capacitor 67). Set the DPU board aside. Step 7. Carefully pull the ZRM board part-way from the 2424 chas
8、sis, until you can access the “BATTERY” ter- minals (next to LED D13). Pull the connector from these terminals, then pull the connector from the nearby “TRANSFORMER OUTPUT terminals, If the clock has a 2400IP Instruction/Monitor Panel, unplug its connector from the “OUTPUT terminal strip (centered n
9、ear the large relays), Remove the board from the clock chassis. Step 8. Orient the ZRM board with the screw terminals towards you, then place the board on a suitable work surlace. Cut Jumper J1 (it is to the left of the row of resistors above IG?) . Step 9. Orient the white PCB supporter with its sh
10、orter stake (the one on the concave side of the curved flanges) downward. Handle this part gingerly: it could break. Insert the shorter stake into the small hole that is inside the three-inch square screened on the upper right section of the board. of the chassis. Reinstall the following connectors
11、onto the board s pin terminals: a. If the clock is equipped with the 2400IP panel, push its connector onto the “OUTPUT” terminal strip. The black edge on the ribbon cable should be oriented to the left (the side of the terminal strip with pin “C”). b. Push the transformer connector onto the “TRANS-
12、FORMER OUTPUT terminal strip; so long as the four holes in the connector mate with the four pins, the connector may be oriented in either direction. c. Push the battery connector back onto the ZRM board s “BATTERY” terminals. The connector is keyed. Step 13. Push the back of the board firmly to ensu
13、re that its front edge connector is fully seated in the cor- responding terminals on the Clock Control Panel (CXP). Step 14. Replace the DPU board in the clock chassis (if you removed it in Step 6), taking care to properly align the board with the mounting tabs and to fully seat the front edge conne
14、ctor with the corresponding terminals on the CXP. If there is a ground wire coming from the middle of this board, reconnect it to Terminal Z on the ZRM board. Step 15. Replace the vertical support bracket and tighten its screw. Step 10. Place the 2401CC module on a suitable work surface and cut Jump
15、er JUl (the jumper is under the connectors, to the left of the IC chip). The failure to cut this jumper could cause the 2401CC to draw excessive current from the 2424; among other things, this could overload the power supply of the master clock and cause it to malfunction. Step 16. Test the installa
16、tion by plugging the master clock into an appropriate AC power source and entering an event for a diiTerent time from what is shown on the display. If the master clock accepts this entry (and does not reset back to 08: 00 am), then both the installation and the 240lCC itself are probably okay. After
17、 completing this test, make sure that LED 023 is off, then short Terminals n and T4 together with a screwdriver or similar tool. After making sure that LED 013 is now lit, unplug the clock again. Step 11. Orient the 2401CC module inside the square Step 17. Replace the back cover with its Eve screws.