Rauland Mcc100 Series Communications Control Panels 电路图.pdf
《Rauland Mcc100 Series Communications Control Panels 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Mcc100 Series Communications Control Panels 电路图.pdf(20页珍藏版)》请在收音机爱好者资料库上搜索。
1、c KI-1174-B DIRECTOR SERIES COMMUNICATIONS CONTROL PANELS MODELS MCCl00, MCCl00A AND MCClOOB FOR SCHOOL SOUND/COMMUNICATIONS SYSTEMS 1 1 RAULAND-BORG CORPORATION ? 3535 West Addison Street, Chicago, Illinois 60618 (312) 267-1300 CONTENTS Section Page Model Variations . 2 Specifications.,. 2 1. DESCR
2、IPTION . 3 2. 3. 4. 5. 6. 7. INSTALLATION . INITIAL ADJUSTMENTS AND LEVEL SETTINGS . OPERATING INSTRUCTIONS . THEORY OF OPERATION . MAINTENANCE . UNIQUE ITEMS PARTS REPLACEMENT LIST . 4 6 7 9 15 16 Limited Warranty Diagram Communications Control Panel Schematic Diagram.KC-1303 1978 RAULAND-BORG CORP
3、. PRINTED IN U.S.A. l0/78 PAGE 1 OF 17 RadioFans.CN 收音机爱 好者资料库 M O D E L V A R I A T I O N S Model MCClOOA uses the same circuit board as the earlier MCClOO Model, but includes an improved TALK/LISTEN switch. Model MCClOOB includes resistorR119 in the talk enable circuitry to accommodate operation w
4、ith the optional VC-6380 Beep Adder. Except for these changes, all infor- mation provided in this instruction manual for the MCCl00 Model is fully applicable to the MCClOOA and MCClOOB Models. S P E C I F I C A T I O N S Rated Output: Frequency Response: 10 watts rms Shaped for maximum intelligibili
5、ty; Approximately 800 Hz to 10 kHz Distortion: Talk Noise Level: -50 dB Type of Output: Balanced 25-volt line Compression Amplifier: RANGE: 20 dB ATTACK TIME: RELEASE TIME: Supervisory Tone (Listen Mode Only): Source Required: Unit Size: Less than 5% 10 msec 1.5 sec DURATION: lOO 20 msec REPETITION
6、R A T E Every 15-20 sec FREQUENCY: Approximately 1.5 kHz 28 Vdc 19 panel x 3 high x 7% deep SPECIFICATIONS SUBJECT TO CHANGE WITHOUT PRIOR NOTICE PAGE 2 RadioFans.CN 收音机爱 好者资料库 - Classroom personnel are alerted to the listening condition a brief tone signal which is sent every 15 to 20 sec to the mo
7、nitored classroom. - Compatible with selective privacy operation.Classrooms equipped with a PRIVACY or PVCY switch may prevent classroom monitoring. Calls from the console are always heard in the by 1. DESCRIPTION 1.1General The Model MCClOO Communications Control Panel provides the communications (
8、intercom) channel for the Rauland DIRECTOR Series School Sound/Communications System. Instant monitoring and two-way communications can be obtained with any classroom. The room is selected at the associated room selector switch panel(s). The communications control channel is designated the ORANGEC c
9、hannel. Simplified equipment operation is assured by using the orange color on all communications related equipment panels,and having step-by-step operating instructions screened on the communications control panel. 1.2 Features The communications control panel provides the following features: - Sta
10、te-of-the-art circuitry using integrated circuits for logic switching and some audio amplification stages. This minimizes power consumption, increases reliability, and reduces maintenance costs. - Fast acting compression amplifier with 20 dB dynamic range assures optimum operation under widely varyi
11、ng listen and talk input levels. This allows input levels to be preset during the equipment installation eliminating the need for volume controls and their constant readjustment. - Amplifier output power rated at 10 watts rms into a balanced 25-volt line provides ample power for talking to 20 rooms
12、simultaneously. - Isolated listen and talk inputs to the compression amplifier using computer-grade reed relays. This prevents cross-talk and gives system operational priority to the communication control panel (console) operator. - Simple equipment operation using PUSH-TO-TALK/RELEASE-TO-LISTEN swi
13、tch and front-panel mounted speaker/microphone obtains two-way communications with classroom. No level adjustments are required by the equipment operator. selected classroom(s) regardless of the privacy switch position. -3- - Compatible with voice call operation. A separate voice call circuit may be
14、 used allowing direct calls to the console operator from the classroom, bypassing selections made at the room selector switch panel. - Provisions for ready field addition of the Rauland Model CCPlOO Administrative Expander Kit. This kit allows administrative communications system operation with up t
15、o three Rauland Model MDClOO Administrative Centers. - Operating power obtained from the common +28 Vdc power source used for theDIRECTOR Series equipment. 1.3 Optional Call Origination Switches There are several different call origination switches available as optional items for the DIRECTOR Series
16、 School Sound/ Communications Systems. Select theswitch that best suits the specific classroom requirements for your system from the following list: RAULAND ANNUNCIATOR MODEL METHOD OS10 Voice or Visual OS11 Voice or Visual 2304F-A Visual 2307 Visual 2302S - 2. INSTALLATION 2.1 Introduction The Comm
17、unications SWITCH TYPE 3-position Locking Spring return Momentary lever from call 2-position - Spring return Momentary lever from call Pushbutton - - - - - - - - Momentary 3-position Locking Spring return Momentary rocker from call Rotary control panelis available either as a factory installed item,
18、completely prewired and tested as an in- tegral part of a DIRECTOR Series School Sound/Communications System,or separately for field installation into an existing sound system. Sufficient information is provided to do a typical field installation. Not every application or interface problem is descri
19、bed. The intraunit connections between the communications control panel and the items that comprise a DIRECTOR Series System are shown on the wiring diagram in the instruction manual provided with either the Model MCAlOO or MCBlOO Master Control Panel. SWITCH POSITIONS AND ACTION PRIVACY NORMAL CALL
20、 - L locking T locking -4- 2.2Equipment Damaged in Transit the This equipment has been carefully inspected and tested at factory prior to shipment. If the equipment was damaged in transit, notify the transportation company immediately to place your claim. 2.3 Mounting Communication Control Panel (Fi
21、eld Installation Only) The communications control panel may be mounted in any standard 19-inch rack. The minimum space requirements are: 3 high by 7 deep. Remember that sufficient open space must be kept behind the chassis for making equipment connections and to allow accessibility for equipment mai
22、ntenance. Mount panel as follows: Step 1. Secure chassis to the rack with screws through the four mounting holes provided. It is recommended that l0-32 or larger hexagon head screws be used. Rauland supplied racks require l0-32 x 3/8 self-locking screws,and turrets require 10 x 3/8 sheet metal screw
23、s and 10-2 Tinnerman-type nuts. The mounting hardware is supplied with the equipment. Step 2. Install front panel on chassis using the two 6-32 x 3/8 binder head screws supp1ied. 2.4 Intraunit Wiring Check List (Communications Control Panel) Use the following check list to verify that factory instal
24、led wiring is intact,and as a guide for making connections in the field. MCClOOB Terminal B Function Connect To Present(d) None Not Used Cl CZ c2 P 4 Z M T Y Audio In/Out * TP Cable Shield MCRlOOA; Term 17 MCRlOOA; Term 13 Audio In/Out MCRlOOA; Term 16 +28 Vdc Input PSX29A or SAX60/lOO None Not Used
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Mcc100 Series Communications Control Panels 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220780.html



Marshall-9100-62-02-Schematic电路原理图.pdf