Rauland Mc1350B Control Console 电路图.pdf
《Rauland Mc1350B Control Console 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Mc1350B Control Console 电路图.pdf(27页珍藏版)》请在收音机爱好者资料库上搜索。
1、-.- 6 ce:J KI-1252-0 DIRECTOR IITMSERIES DESK-TOP CONTROL CENTERS FOR SCHOOL SOUND/COMMUNICATIONS SYSTEMS - RAULAND-BORG CORPORATION ? 3535 West Addison Street, Chicago, Illinois 60618 (312) 267-1300 - - - - - - - - - - - - ATTACHMENTS This service manual includes the following items: MCI350 to SPL1
2、425 System Wiring Diagram KM-0539 Two Room Selector Panels Wiring Diagram KM-0540 Three Room Selector Panels Wiring Diagram KM-0541 DIR350/DIR350L Typical System Wiring Diagram And Multiple Masters Connections Diagram KM-0536/ KM-0535 MCI350 Master Control Intercom Diagram Room Selector Switch Panel
3、 Instruction Manual EQUIPMENT MODEL COMPLEMENT KC-1362 KI-1200 DIR350B DIR35OLB -_- INCLUDED ITEMS -7- X X X SW25 X SWL25 X PSL25 X MCI35OB Room Selector Panel Room Selector Panels/W LightCall-In Power Supply (6.0 Vdc 100 mA) Master Control Intercom Panel VC-6365*Miscellaneous Hardware Items X VC-63
4、66*Miscellaneous Hardware Items X X PCC300A Cabinet W/Accessories *VC-6365 and VC-6366 are assembly numbers used for internal factory control and fabrication purposes. Do not order hardware items using the VC-6365 and VC-6366 numbers. 01980 RAULAND-BORG CORP. PRINTED IN U.S.A. 3/80 PAGE 1 OF 1 7 Rad
5、ioFans.CN 收音机爱 好者资料库 S P E C I F I C A T I O N S Operational Channels:. Two;PROGRAM and INTERCOM. Both channels work independently, permitting simulta- neous PROGRAM distribution to selected rooms and two-way INTERCOM with another room. Unit can be converted to single- channel operation by jumpering
6、 option on circuit board. Room Capacity: Rated Power Output: Output Available: Frequency Response: Distortion: PROGRAM Channel: Less than 2% at RPO Noise Levels (below RPO): Microphone:- 60 dB Auxiliary: - 70 dB Intercom: - 50 dB Inputs: 25, expandable in groups of 25 rooms up to 75 rooms with addit
7、ion of optional SW25 and SWL25 Room Selector Panel (s). PROGRAM Channel: INTERCOM Channel: 35 watts RMS 5 watts RMS 25V balanced and center-taped. Readily convertible to 5V (45 ohms) balanced output. Either output is transformer isolated. PROGRAM Channel:Flat within + 3 dB, 50 Hz to 15 kHz INTERCOM
8、Channel:Shaped for maximum intelligibility; approx- imately 2 kHz to 10 kHz. Microphone:Two balanced 150 ohm inputs using built-in Model R1050 Microphone Transformers. Auxiliary: Two unbalanced 5OOK ohms. Input Sensitivity (for RPO): Microphone: 0.3mV for low impedance. Auxiliary: 0.25V PAGE 2 Radio
9、Fans.CN 收音机爱 好者资料库 Supervisory Tone (Intercom Listen Mode) : Duration: 200 msec Repetition Rate: Every 13 3 sec. Frequency:Approximately 1.2 kHz. Power Requirements: 120 Vac (105-130 V); 60 Hz; 65 watts. Safety Devices: Resettable circuit breaker to input of ac power tra sformer. Automatic reset- ti
10、ng 195 7 F thermostat on inside of rear chassis senses heat sink temper- ature. MCI350 Panel Size: 19 W x 3 H x 10 D DIR350 or DIR35OL Unit Weight: 33 lb. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE 1. DESCRIPTION 1.1 General T.M. The Rauland-Borg Director II Series Desk-Top Control Ce
11、nters are ideal for small and medium-sized schools requiring the features avail- able on console-type control centers. For these schools, the Desk-Top Control Centers thoroughly fulfill communications and program distri- bution needs in a space-saving and cost-saving design which is simple to operat
12、e. 1.2 Program Channel Complete facilities are provided for distributing a variety of program materials from microphone, radio,cassette or tape player, and/or tape recorder. Program distribution to individual classrooms, or selected groups of rooms,or to all rooms is extremely flexible and easily ac
13、complished using the follow-the-color operational tech- nique. 1.3 Intercom Channel - The Desk-Top Control Center provide efficient control of communi- cations throughout your school. Instant,effective two-way voice com- munications can be obtained with any classroom. Classrooms may easily call and
14、communicate with you. Emergency announcements to all rooms is simply made by depressing the ALL-CALL button and speaking into the local microphone/speaker built into the front panel. PAGE 3 2. ACCESSORIES 2.1 Rauland Model 47RCA Remote Control Adapter - - Prepares microphone inputs to program channe
15、l for operation with remotely controlled volume. An optical-isolator within the 47RCA provideshum-freeremote operation as the remote volume control signal is completely isolated from the amplifier input circuits. 2.2 Rauland Model 47RVC Remote Volume Control - - - Provides remote (up to 2,000 feet)
16、volume control of the micro- phones without changing the level of auxiliary sources. Accurate ad- justment to the desired volume level is provided by the calibrated faceplate and the potentiometer taper. Must be used with the Rauland Model 47RCA Remote Control Adapter. 2.3 Rauland Model DO158 Clock
17、Relay - Provides switching that sends a continuous tone to all classrooms indicating class change. Compatible with single-channel, classroom change systems. Switch closure from programmed time-change clock enables DO158 clock relay. OFF buss is gathered and tone frominternal MCI350 circuitry is sent
18、 to all classrooms for the class change notifi- cation. 3. INSTALLATION 3.1 Introduction A well planned equipment installation saves time and assures best equipment performance. Evaluate the following items: Equipment location and type of equipment mounting. Number of microphone inputs to be used. F
19、ield conversion for classroom time-change notification. , Field conversion for remotely controlled functions. Type of output to be used and if line-matching transformers are needed. System wiring to and from amplifier. WARNING - Installation of optional accessories requires removal of amplifier cabi
20、net which could present an electrical shock hazard. Installation of these items must be performed by an authorized Rauland-Borg serviceman. PAGE 4 3.2 Equipment Damaged in Transit This equipment has been carefully inspected and tested at the fac- tory prior to shipment. If the equipment was damaged
21、in transit,notify the transportation company immediately to place your claim. 3.3 How To Access The MCI350 (Desk-Top Models Only) Some disassembly of equipment mounted in desk-top models is required in order to access the MCI350 for connection of field wiring, installa- tion of optional accessories,
22、 modes of operation. and modification to accommodate special Connection of field wiring requires only removal of the back cover to access the screw terminals provided on the rear of the MC1350. Installation of optional accessories and modification to the circuit board requires removal of all equipme
23、nt and blankpanels mounted in the cabinet. Removing An Equipment Panel/Chassis - - - - - - - - - - - - - Step 1.Remove dresspanelby unscrewing two screws from front of panel. step 2.Unplug interconnecting cables,as required in order to free chassis from other units. Tag plugs for identification, if
24、necessary. Step 3.Remove four screws securing chassis to cabinet side rails. Step 4.Re-install by reversing the above sequence. 3.4 Conversion For Remotely Controlled Volume -1- Step 1.Access the MCI350 circuit board as described in Paragraph 3.3. Step 2.Insert the Model 47RCA Remote Control Adapter
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Mc1350B Control Console 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。



Marshall-9100-62-02-Schematic电路原理图.pdf


