Rauland Telecenter V - Ki-1519A-Crt3 Staff Telephone Installation 电路图.pdf
《Rauland Telecenter V - Ki-1519A-Crt3 Staff Telephone Installation 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter V - Ki-1519A-Crt3 Staff Telephone Installation 电路图.pdf(4页珍藏版)》请在收音机爱好者资料库上搜索。
1、RAULAND-BORG CORPORATION l 3450 West Oakton Street, Skokie, Illinois 60076-2951 l (708) 679-0900 PRELIMINARY DESCRIPTION MOUNTING PARTS The CRT3 is a dial-less telephone designed for use with the Rauland Telecenter systems. On the Telecenter IV and Telecenter TCS, it can serve as a single-link or a
2、multi- link staff phone. On the Telecenter 5500, it can serve as a common-line staff phone in conjunctionwith an ADS55 10 Console and an RS503 Staff-Telephone Adapter. In addition to the standard“tip”and“ring”wiring, the CRT3 has a second pair of contacts that provide a dry con- tact when the phone
3、is lifted off-hook. This connection enables the phone to call in when the handset is lifted. Important: Never connect the CRT3 to the modular jack of an Administrative Display Telephone: the CRT3 s extra set of contacts would place a short across the display lines. The telephone comes with the follo
4、wing mounting parts: Qty. Description 1 Modular jack. 1 Short four-wire connector with a modular plug at each end. 1 Long four-wire connector with a modular plug at each end. 2 #632 x 3%” machine screws. 1 Locking clip (to secure the phone to the mounting plate). The CRT3 has been approved by the Fe
5、deral Commu- nications Commission (F2SGBN-7273S-TE-E) . This Telephone is Not Hearing-Aid Compatible. The following will need to be supplied by the user: 4 Wiring ftom the Telecenter to the telephone. 4 Single-gang electrical box. 4 On the TC5500: ADS55 10 Console, RS503 Module, and speaker. INSTALL
6、ATION These instructions tell how to mount the telephone. Wiring diagrams are included in the main Telecenter IV manual (K conduit is also strongly recommended. Connect all Step 4. Fasten the system wires to the appropriate screw terminals. Push the front plate onto the module. then rotate it 180” (
7、see the following illustration). Step 5. If the telephone is to be wall-mounted, skip to Step 6. If the telephone is to be desk-mounted, use the longer modular cord to connect the phone to the jack, then set the phone in place. Skip to Step 9. Step 6. If the telephone is to be wall-mounted, locate t
8、he u m I! u 1 - 1 Step 2. Set aside the hont plate from the modular jack. Orient the module in keeping with its 7OP marking. Find the unused hole near each screw terminal. Pull each field wire through the appropriate hole. On the modular jack, the TI (green wire) and RI (red wire) terminals provide
9、the conventional “tip” and “ring” telephone contacts; the AUX (black wire) and GZV (“ground” -yellow wire) provide a dry contact for calling in. Step 3. Secure the module to the back box with the 0 two #6 screws provided. Use the two holes immediately Step 7. To complete the wall-mounting, orient th
10、e inside the module s studs. phone with the hook switch on top and use the shorter 01988 RAULAND-BORG CORPORATION l Printed in U.S.A. Orig. 5187 Rev. 3188 _ . Page 1 of 2 RadioFans.CN 收音机爱 好者资料库 cord to connect the phone to the jack. Align the slots in the base of the phone with the studs on the mod
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Ki-1519A-Crt3 Staff Telephone Installation 电路图 Ki 1519 Crt3
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220812.html



Marshall-9100-62-02-Schematic电路原理图.pdf