Rauland Mcz300 Master Control Panel 电路图.pdf
《Rauland Mcz300 Master Control Panel 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Mcz300 Master Control Panel 电路图.pdf(11页珍藏版)》请在收音机爱好者资料库上搜索。
1、MCZ300 Director III Series Master Control Panel Table of Contents . KI-1603 Installation, Troubleshooting, and Drawings RAULAND-BORG CORPORATION l 3450 West Oakton Street, Skokie, Illinois 60076-2951 l (847) 679-0900 General Information 2 Description . . . . . ._.,.,.,. 2 Unpacking.,.,.,.,. 2 Suppli
2、edRack-Mounting Parts . . . ._.,.,.,.,.,.,.,._., 2 Equipment Damaged in Transit. . . . . . . . . . . 2 specmcations 2 Installation 3 -. . . . . . . . . . . . . , . . . . . . . 3 . . 3 . 3 . . . . . . . . . . . . . . . . . . . . . . . . . 3 . 3 . 3 Mechanical . Rack- or Turret-Mounting. . Electrical
3、. Power and Grounding . FieldWiring . Talk-Level Adjustment . Emergency Talk-Level Adjustment . Options . Disabling the Periodic Supervisory Tone, . Disabling the Repeating Call-in Tone . MTG100 Emergency Tone Generator . HS246 Emergency Telephone, . Connection to a Clock System . ChronoCom” Jumper,
4、 . Back-Panel Connections, Controls, and Indicator . 4 . 4 . 4 5 . . : . 4 . 5 Screw Terminals (J-1) . Wire-Wrap Terminals ( J-2 ) . Multi-Channel Functions 7 Independent Mode . Bus-Gathering Mode. . Middle-Priority Level . Adjustable High-Priority Levels, . Troubleshooting 8 - Drawhlgs 9 MCZ300 Sys
5、tem Wiring Diagram, . KM0952 HS246 Emergency Telephone . KM0992 MTG100 Mult-tone Generator (Schematic), . KC1309 MCZ300 Schematic . KC1627 (61990 RAULAND-BORG CORPORATION l Printed in U.S.A. Orig. 5/90. 3rd Pmt. l/93 Pagelof12 160300 RadioFans.CN 收音机爱 好者资料库 MCZ300 Master Control Panel: Installation
6、General Information Description This Director III Master Control Panel offers dependable program distribution and two-way intercom communica- tions. Its ease of operation can be gauged by the three-step instructions on the front panel. To further simplify the operation, the knobs and push buttons ar
7、e color-coded to match the “Follow-the-Color” channel markings on the associated switch panels: orange for intercom, green for the “A” Channel program-distribution, and blue for the optional “B” Channel program distribution. The control panel has a fifteen-watt intercom amplifier and five program in
8、puts: one dedicated to the built-in Console microphone and four that can be set for either microphones or program sources (e.g., phono, tape, tuner). The panel is compatible with the Rauland SW25, SWL25, SWT425, and SWL425 Room-Selector Panels and the newer Director III Series equipment (MCB300, etc
9、. The attached system wiring diagram (KM0952) shows the connection of the standard and optional equipment. For more detailed information, see the “Back-Panel Connections, Controls, and Indicator” section of this manual. Both normal and emergency announcements can be made without resetting individual
10、 room switches. Controls trols for all-call and emergency announcements are stand- ard on the MCZ3OO, and an MTG100 Tone Generator can easily be interconnected to provide a variety of alerting and emergency tones. Unpacking The MCZ300 comes assembled. The only separate items packed with the unit are
11、 the screws, washers, and Tinner- man nuts for fastening the chassis to the rack: Supplied Rack-Mounting Parts Rauland w* DCSCriptbtl Part No. 4 Black x10 flat washers. WJO305 4 Black fiber washers. WL0315 4 Tinnerman xl32 speed nuts. AB3640 4 Black machine screws (xl32 x 5h B0439 panhead Phillips).
12、 Equipment Damaged in Transit The MCZ300 was carefully inspected and tested at the factory before it was shipped. If the equipment has been damaged in transit, notify the transportation company at once to place your claim. Specifications Rated output8 Gmtrols and Indicators: Program 0.5 v (into 10 K
13、m. Intercorm 15 watts RMS (balanced, 25-V line). Inputs: 1 internal Console micro- phone 4 rnics (balanced, 150 i2) con- vertible to auxiliary (unbal- anced, 150 Kf These specifications are subject to change without notice. 5 Program-seled push but- tons. 4 Push-button controls: Tone, All-Call, Emer
14、gency, and Pm-to-Talk. 2 Level controls: Progmm Vol- ume (green), and LkC 1.7 A max. with both MCZ300 and MCB300. 19 wide (front panel), 3%” high, 71/z” deep (48.3 cm x 8.9 cm x 19.0 cm); 9” (22.9 an) deep with the heat sink. Black matte finish screened with white. Pag6 2 8i92 RadioFans.CN 收音机爱 好者资料
15、库 .- MCZ300 Master Control Panel: Installation Installation .- Mechanical The MCZ300 is designed for mounting in a standard 1Pinch rack or in a turret (Rauland Model T1600 or T2600); it requires 3a inches of vertical space. Whatever the site, a well-planned equipment installation will save time and
16、assure optimum equipment performance. The following factors should be considered: 4 The location of the equipment and the type of mounting. 4 The numbee of inputs. 4 The field conversions for such options as a tone generator and input switches, and the advisability of completing them before mounting
17、 the MCZ300. 4 The addition of associated equipment, such as the MCB300 Program Control Panel. 4 The system wiring to and from each amplifier used. Rack- or Turret-Mounting Other than the normal precautions for (a) avoiding hot spots or areas with severely restricted air flow and (b) allowing suffic
18、ient clearance at the rear for accessing the equipment, the only location restriction is that the MCZ300 not be placed directly above or below a large power transformer (e.g., one in a power amplifier), which could cause hum. The procedures for installing the control panel are the same for both rack
19、- and turret-mounting. Note: The unit should not be mounted until the field .r conversions for any options have been completed. Mounting: At the selected mounting position, follow the appropriate procedures (depending upon whether the mounting holes are untapped or tapped): Step 1. Ifthe rack s bole
20、s aremt tapped, insert the NO speed nuts over the four holes that you will use. Step 2. Prepare the four supplied machine screws by placing a black metal washer and then a fiber washer over each one. Step 3. Insert the MCZ300 in the rack and fasten it with the four prepared screws. Electrical Power
21、and Grounding ., The MCZ300 receives its power via the “+28V” and “COM” terminals on its back panel. To make full use of the unit s 15watt intercom amplifier, select a power source that can supply at least 1.5 amperes for the MCZ300 itself (at least 1.7 amperes if the system includes an MCB300). Rau
22、land s PSX300 DC Power Supply, rated at 2 amperes, can comfortably handle either requirement and is the recommended choice. Alternatively, Rauland s school am- plifiers, such as the DAX60 and DAX120, can supply 1.2 amperes of 28VDC power, but would limit the intercom power to less than 15 watts. Bot