Rauland Tc5000 - Ads5010 Administrative Station Installation 电路图.pdf
《Rauland Tc5000 - Ads5010 Administrative Station Installation 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Tc5000 - Ads5010 Administrative Station Installation 电路图.pdf(5页珍藏版)》请在收音机爱好者资料库上搜索。
1、KI-1419 ADS5010 ADMINISTRATIVE STATION INSTALLATION RAULAND-BORG CORPORATION ? 3535 West Addison Street Chicago, Illinois 60618 (312) 267-1300 GENERAL As a self-contained desk-top unit, the Model ADS5010 Administrative Station has few special installation requirements other than the cabling shown in
2、 riser diagram and related drawings. (Refer to System Planning and Cable Installation guidelines provided in KI-1426). Field wiring required for the ADS5010 is that between the NCS2011 Wall Receptacle and the TC5000 Area Control Unit. (See TC5000 Installation manual KI-1417 for information on termin
3、ating Administrative Station wiring to ACU modules.) Remaining requirements and recommendations for ADS5010 Installation are described in this manual. PACKAGING The ADS5010 Administrative Station is packaged completely assembled in one carton. One NCS2011 receptacle is provided with each Administrat
4、ive Station. Additional receptacles may be obtained if desired for optional control station locations. The ADS5010 includes two 6-32 x 3/4 Phillips-head finish screws. LOCATION The ADS5010 Administrative Station should be located on a table, desk, or counter capable of supporting a load of at least
5、10 pounds (4.5 kg). The outside dimensions of the ADS5010 are 11-3/8 inches wide by 6-l/2 inches deep by 4-3/8 inches high (28.89 cm by 16.51 cm by 11.11 cm), not including the handset. Space for the unit should be reserved accordingly. A 6-foot (1.83 m) plug-ended interface cable is provided with t
6、he ADS5010 for connecting the unit to the NCS2Oll Wall Receptacle. The Wall Receptacle should be located within 5 feet (1.53 m) of the desired Administrative Station location. Greater flexibility in control station location is afforded if the receptacle is located just under the height of the desk o
7、r countertop, rather than at baseboard level. NOTE: Each NCS2Oll Wall Receptacle requires at least a single-gang back box. We recommend Raco 245 box, 4-ll/l6 inch square with Raco 838 3/4-inch raised device. 01985 RAULAND-BORG CORP. PRINTED IN U.S.A. 5/85 Page 1 of 5 RadioFans.CN 收音机爱 好者资料库 Finally,
8、 user comfort and convenience are to be considered when choosing the Administrative Station location. For instance,the height of the surface on which the control station is placed can be a determining factor in the incidence of operator fatigue. Light and ambient noise levels should not be highenoug
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Tc5000 Ads5010 Administrative Station Installation 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220822.html



Marshall-9100-62-02-Schematic电路原理图.pdf