1、SWL25 Room-Selector Installation KI-1200A Panels Rauland-Borg Corporation ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (847) 679-0900 General Information The SW25 offers room selection only (no call-in signal). Description The SWL25 also provides a call-in signal. When a call The SW25 an
2、d SWL25 panels are used with all Director is made from a switch in the classroom, an LED lights next Series sound and communications systems. These panels to the corresponding number on the panel and a tone alerts let you selectively connect up to 25 rooms to either the the console operator to the c
3、all. The LED lamp remains lit program or the intercom channel. There is also a center until the operator answers the call, at which time the lamp OFF position. Color-coded directions identify each chan- automatically shuts off. nel: green for program, and orange for intercom. Installation Cabling Re
4、quirements i./ Systems using the SW25 (no call-in signal) require one twisted pair in a shield for each speaker station. Systems using the SWL25 (call-in signal) require one additional conductor within the shielded cable for each speaker station. Use #22-AWG solid or stranded conductors with 22-AWG
5、drain wire. If you re using insulation-piercing connectors, the outside diameter of any wire, including its insulation, must not exceed 0.095”. Cable Routing and Strain Relief Route the cables as shown in the diagram. Secure them with three plastic cable ties through the guide loops in the rear brac
6、ket. Leave service loops in the cables used to interconnect the equipment panels and at least a one-inch slack in each cable. This permits reconnection when required. Connect the twisted pair to terminals D and E, and the drain wire to terminal G for each line circuit. On Model SWL25 only, connect t
7、he third conductor for calf-in to terminal T(Trigger). Connector or Bus Wiring L ,. /. There are three terminals (OFF, A, 0 at the ends of the switchbank that will be interconnected in a factory-wired system. These interconnections provide loop-through for common functions, especially between multip
8、le switch- banks. For wiring details, read the instruction manual for the proper program and intercom equipment panel. When you re wiring to these end terminals, you may need to cut slots in the connector shells for loop-throughs between switchbanks. Recommended Terminations Insulation-piercing conn
9、ectors are the fastest, most re- liable way to terminate wire to the switchbank. These connectors must be ordered separately. Order one SK-2522 Connector Kit for each switchbank. The kit contains 25 four-terminal connectors for 22-AWG wire. The attached manual, KI-1564, tells how to install these co