1、u L 2524 KI- 1629B Master Clock and Intercom Controller Programming 1 1 - i RAULAND-BORG CORPORATION l 3450 West Oakton Street, Skokie. Illinois 60076-2951 l (847) 679-0900 Table of Contents General Information 2 Description . . . . . . . . . _ . . . . 2 Manuals.2 Power-up . . . . . . . . . . . . .
2、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Programming Summary 3 Disabling Programming. . . . . 3 Sequence.,.3 Access to Programming . . . . 3 General Methods . . . . . . . . 3 Exiting. . . . . .4 Planning 4 Information Needed . 4 Planning Charts. 4 . , . Zones Char
3、t . .4 Stations Chart . 5 The Events Chart . 5 Clock Modes A-F 7 Mode A (Preprogrammed Clock Codes) . 7 Mode B (Custom Clock Code) . 7 Creating a Custom Code . 7 Entering the Custom Code . . 7 Mode C (Holidays and Time Changes) . 8 Mode D (Edit Holiday events) . 8 Mode E (Relay Panels, Comm Activati
4、on) . 9 Mode F (Events: Totals and Erase All) . 9 Clock Modes 1-6 10 Mode 1(Date) . 10 Mode 2 (Time) . 10 Mode 3 (Enter Regular Events) . 10 Mode 4 (Edit Regular Events) . 11 Mode 5 (Zone Duration) . 12 Mode 6 (Activate Zones and Schedules) . 12 Mode 0 (Run) . 13 Communication Modes 13 Entering the
5、“Comm” Modes . 13 0 1994 RAULAND-BORG CORPORATION l Printed in U.S.A. Page 1 of 20 Orig. 4/90. Rev. 1/91. 6/94. 162902 RadioFans.CN 收音机爱 好者资料库 2524 Master Clock and Intercom Controller Programming Table of Contents (cont d) Mode 1 (Room Numbers) . . . . 13 Mode 2 (Zones and Scanning) . . 13 Mode 3 (
6、System Options) . . . . 14 TC4200 Display . . . 14 Automatically Connect Priority Call-ins . . . . . . 14 Remote Phone . . . 14 Mode 4 (Monitoring Duration) . . . 15 Mode 5 (Call-in Sensitivity) . . 15 Mode 0 (Run) . . . . 15 Work Sheet for Custom Secondary-Clock Code 16 Example . . . . . . . . . .
7、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Commentary: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . _ . . . . 16 Programming Charts 17 General Information Description The Rauland 2524 is a multi-function Master Clock and Communications Control
8、Center. As a master clock, it will synchronize virtually any kind of secondary clock and control up to 350 “events” (such as sending tone signals or turning lights and equipment on and off). As an intercom controller, it adds control of room-switching functions and display functions to Director III
9、intercom- control panels. Manuals This manual tells how to program the 2524 for both clock and intercom functions. The first section gives the basic programming procedures. The “Clock Modes A-F” section explains the programming for the general settings needed by the unit, whether it is used only as
10、a master clock or also as a control unit for communications. The last two sections deal with the clock and intercom func- tions, respectively. Generally, the Clock Modes A-F, especially Clock Mode A, should be done before the numerical modes. Refer also to KI-1628, 2524 Installation, and KI-1630, 25
11、24 Opera- tion. Following the text are four tables that list all of the programming functions. Also attached are a work sheet for devising a special clock-correction code and charts for planning the system programming. Power-up When the 2524 is turned on, its displays normally appear as follows: the
12、 “Mode” window reads “0” (Run Mode), the “Time” window shows the current time, the “Sched” (“Schedule”) window shows a flashing “P” (to indicate that the power was off), and the “Clock” LED lights (to show the unit is set for clock operation). Push any key to stop the flashing “P.” The “Sched” windo
13、w will show the number of the schedule currently in use. Note; If the battery was “disabled” (see IL0341 in KI-1628), the “Time” display may be random. In this case, set the date and time (Clock Modes 1 and 2). Page 2 6/94 RadioFans.CN 收音机爱 好者资料库 2524 Master Clock and Intercom Controller Programming
14、 Programming Summary This section gives the procedures for accessing, chang- Mode 4. The remaining modes may be programmed in any ing, and entering programming information. order. Access to Programming . After this summary, there is a section on planning. Then the three groups of programming modes a
15、re explained. The alphabetical modes (A-F) are explained first, because this group affects both clock and intercom operation; moreover, these settings are usually entered during setup and left that way, except for the annual holiday and Daylight Savings Time changes. The other clock and the intercom
16、 modes follow in that order, To begin programming, the clock must be in the Clock Run Mode (“0”). Step 1. Enter the Security Code (Funct 2524 that is, press in succession the Funct, 2, 5, 2, and 4 keys): Disabling Programming Jumper J2 on the main circuit board of the 2524 can prevent any programmin
17、g changes from being effected. Although the displays would still change as a user entered different values, these changes would not be recorded in the EEPROM and so the old settings would remain in effect. The only changes that could be effected from the front panel would be the time and date, and n
18、ot even these could be changed from a computer running the T2524 Diagnostic Program and connected to the 2524 s serial port. The “0” in the “Mode” window will flash, meaning that you can select a programming mode. If you pause more than five seconds between keystrokes or enter invalid keystrokes, th
19、e clock will display “ Err0, ” beep, ” and, after a moment, revert to the Clock Run Mode. Step 2. To select the Clock Modes, skip to Step 3. To select the “Comm” modes, push the white Clock/Comm button, The Comm ” LED will light steadily, a “1” will flash in the “Mode” window, and a P” will appear i
20、n the “Sched” window. As viewed from the front of the 2524, J2 is near the right rear comer of the circuit board, near the four-pin header of the serial port. J2 has three pins and a sleeve jumper that slides over two pins. To disable the program- ming, place the sleeve jumper over the middle and re
21、ar pins (the “DIS” setting). To enable programming, place the sleeve jumper over the middle and front pins (the “EN” setting). Note: Once you select intercom programming, you can only select those “Comm” modes. To select the clock modes, you have to first exit to the Clock Run Mode, then begin again
22、 with Step 1. Step 3. To select a numbered mode (l-9, type in its number; to select a letter mode, press Funct while you type the corresponding number (“1” for “A,” “2” for B,” etc.). Caution Accessing this jumper require removing the top cover of the 2524, which, in turn, entails removing the power
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Td21 And 1100 2524 Master Clock Intercom Programming 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220843.html



Marshall-9100-62-02-Schematic电路原理图.pdf