Rauland Telecenter V - Dax60-Dax120 Power Amplifier With Schematics 电路图.pdf
《Rauland Telecenter V - Dax60-Dax120 Power Amplifier With Schematics 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter V - Dax60-Dax120 Power Amplifier With Schematics 电路图.pdf(21页珍藏版)》请在收音机爱好者资料库上搜索。
1、Installation and Service KI-1480B DAX60 60-Watt Power Amplifier DAX120 120-Watt Power Amplifier Rauland-Borg Corporation Issued: 07/08/98 Page 1 of 18 RadioFans.CN 收音机爱 好者资料库 Copyright 1998 by Rauland-Borg Corporation, all rights reserved. This document contains users information on technology that
2、is proprietary to Rauland-Borg Corporation. Permitted transmittal, receipt, or possession of this document does not express license or imply any rights to use, sell, design or manufacture this information. No reproduction, publication, or disclosure of this information, in whole or in part, shall be
3、 made without prior written authorization from an officer of Rauland-Borg Corporation. Rauland-Borg Corporation Rauland-Borg Corporation 3450 West Oakton Street Skokie, Illinois 60076-2958 (847) 679-0900 RadioFans.CN 收音机爱 好者资料库 Table of Contents GENERAL INFORMATION. 4 DESCRIPTION. 4 REVISION HISTORY
4、. 4 DRAWINGS, DIAGRAMS, AND OTHER GRAPHICS. 5 PACKING LIST/UNPACKING PROCEDURE. 5 INSTALLATION. 5 Rack-Mounting . 6 Turret-Mounting (DAX6O only) . 6 Input Connections. 7 Output Connections. 7 Selecting Balanced or Unbalanced Output Connections. 7 Grounding the Center Tap. 8 Split-Center-Tap Operatio
5、n. 8 Auxiliary DC Power Supply. 8 POWER CONNECTION. 9 Converting the Amplifiers to 240 VAC. 9 SETTING THE INPUT LEVEL” CONTROL. 9 REPLACING THE FUSE. 9 INITIAL TROUBLESHOOTING.10 SERVICE INFORMATION.11 Locating the Test Points.11 Measuring DC Voltages.11 Measuring AC Voltages.12 Locating the Driver
6、and Power Transistors.12 Removing and Replacing Transistors.13 Testing Transistors.14 DAX6O Circuit Description .14 DAX12O Circuit Description.14 APPENDIX A: LIMITED WARRANTY/SERVICE POLICY.17 LIMITED WARRANTY.17 SERVICE POLICY.18 NKI1480B DAX60 and DAX120 AmplifiersInstallation Page 4 of 18 (Jul-98
7、) General Information Description The Rauland DAX Series amplifiers are designed for use with Raulands institutional program and communication Systems. They offer high-quality sound and dependability. They can be driven to their rated power output by an input signal as low as 0.3 volts. Their transf
8、ormer-isolated, 25-volt balanced output matches the output of Raulands communication panels; they also have a 70.7-volt balanced output. Their outputs can operate with a split center tap with Raulands Telecenter 5000 and Responder 3000 systems. The amplifiers are listed by Underwriters Laboratories.
9、 The DAX amplifiers offer helpful power connections for related equipment: three 120-VAC three-pin grounded outlets, and a floating auxiliary DC power output (28 VDC, 1.2 A) that can be used for Raulands Director Series control panels, preamplifiers, graphic equalizer, and other equipment. The ampli
10、fiers come with black-enamel face panels. Optional brushed-chrome dress panels-the RP2525 (DAX6O) and RP2700 (DAX12O)are available. Revision History This manual has been reformatted. No substantial changes were made during the reformatting process. 1 NKI1480B DAX60 and DAX120 AmplifiersInstallation
11、Page 5 of 18 (Jul-98) Drawings, Diagrams, and Other Graphics This document includes the following drawings, diagrams, and/or supplemental graphics: ? Transistor Replacement DrawingExploded (IL0253) Packing List/Unpacking Procedure Although the amplifier was thoroughly checked at the factory, we reco
12、mmend that you inspect the amplifier, the enclosed parts, and the shipping container for signs of improper handling during shipment. In case of damage, immediately place a claim with the dealer, the distributor from whom you purchased the unit, orif the unit was shipped directly to youwith the carri
13、er. The following parts are included with the amplifier: QuantityPartPart Number 4Rack-mounting screws for tapped holes (10-32 x hex-head, SEMS, unslotted, machine) WA202 4Rack-mounting screws for untapped holes (10 x pan-head, slotted, thread-forming) WA102 4#10 Tinnerman “U” type speed nuts for un
14、tapped rack holes AB1889 Installation The amplifier should be rack-mounted where there is adequate ventilation, a moderate temperature, an AC power outlet, and provisions for grounding. The rack should have the standard 19-inch width and a vertical space of at least 5 1/4 inches (DAX6O) or 7 inches
15、(DAX12O). It is recommended that additional space be left above and below the amplifier to prevent hum from being introduced into adjacent equipment (such as preamplifiers), to provide additional ventilation, NKI1480B DAX60 and DAX120 AmplifiersInstallation Page 6 of 18 (Jul-98) and to allow easier
16、access for servicing. Allowing an inch of space behind the amplifier for connections, the rack requires a total depth of seven inches. A cooling fan is recommended when the rack is enclosed and any of the following conditions exists: ? The combined rated output power of all the equipment exceeds 250
17、 watts RMS; or ? The input from the AC power line exceeds 500 watts; or ? Restricted air flow in the rack may create extreme heat. ? Important: Failure to observe the preceding precautions could result in overheating that could damage the equipment or create a fire hazard. Rack-Mounting The DAX Seri
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Dax60-Dax120 Power Amplifier With Schematics 电路图 Dax60 Dax120
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220852.html



Marshall-9100-62-02-Schematic电路原理图.pdf