Rauland Telecenter Iv - Ki-1582-Interconnect Planning 电路图.pdf
《Rauland Telecenter Iv - Ki-1582-Interconnect Planning 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter Iv - Ki-1582-Interconnect Planning 电路图.pdf(38页珍藏版)》请在收音机爱好者资料库上搜索。
1、Interconnect Planning KI-1582 Telecenter IV Interconnect Planning RAULAND-BORG CORPORATION ? 3450 West Oak-ton Street, Skokie, Illinois 60076-2951 ? (708) 679-0900 Table of Contents Introduction .1 Survey of TCIV System Requirements.2 Survey of TCIV-PBX System Requirements. 4 E KI-1584, the Programm
2、ing Procedures; and the Glossary of Terms in KI-1587, Drawings and Data. warning: Do not attempt to plan an interconnect system without fully understanding how to obtain the features available through system programming. If the TCIV will not be connected to an on-premise PBX, go to the Survey of TCI
3、V System Requirements; otherwise, go to the Survey of TCIV-PBX System Requirements. 1989 Rauland-Borg Corporation (Orig. l/89) Page 1 of 38 RadioFans.CN 收音机爱 好者资料库 Interconnect Planning Survey of TCIV System Requirements Summary: Get a general view of the interconnect and communication problems to b
4、e addressed by the TCIV system at this location and a full picture of the current system. Obtain data on the numbers and types of stations and trunks in the present and required system. If planning for a new construction project and there is no site to visit and little information available, try vis
5、iting a similar organization in the same district. Then, make a point of repeating the survey on-site before the actual installation: at that time, make any changes required to ensure the system design will meet the customers requirements. Note: This procedure is for a system supported fully by the
6、TCIV. A separate survey procedure is provided for systems where a PBX will handle most of the incoming traffic (Survey of TCIV- PBX System Requirements). Step 1. Determine which of the following cases best describes the office situation where incoming calls are to be answered and if it is representa
7、tive of how the customer wants to operate. Case 1. The primary task of answering incoming calls, at least during the busy hour, is assigned to one person (the attendant or operator) who will transfer most calls to appropriate adminis- trative stations. Answering calls and transferring them is this p
8、ersons job and little time will be spent handling calls in any other fashion. A few people may be available to help answer incoming calls when necessary; however, it is desired that the call answering system be efficient enough not to restrict the main attendant from quickly answering and transferri
9、ng calls. case 2. No attendant is assigned. Instead there are 3 to 6 people in the office capable of answering and handling most calls directly. During the busy hour there will be enough people to handle all of the calls as long as they have the ability to occasionally put someone on hold. Any one o
10、f these people can easily pick up on any call. Transferring a call is a fairly infrequent require- ment. If case 1: A TC4400 Call Control Console is indicated. However, a KSU may work satisfactorily if the maximum rate of answering incoming calls does not exceed 20 to 30 per hour for any individual
11、and transfer-target extensions are seldom busy. If case 2: A KSU approach may provide the best solution. Step 2. Estimate the maximum number of incoming calls expected during any one hour of the day or week: Maximum Expected Calls/hour = Step 3. Determine how many administrative phones are required
12、and the number which will have access to outside lines: Administrative Phones With Access: Total Administrative Phones: Page20138 1989 Rauland-Borg Corporation (Orig. 1/89) RadioFans.CN 收音机爱 好者资料库 Interconnect Planning Step 4. Determine if the number of current or planned general purpose Central Off
13、ice trunks (ex- cluding DIL trunks dedicated to private lines) in the system will exceed 10. If so, system requirements may exceed TCIV traffic handling capacity. Note: Use the Traffic Handling Requirements procedure provided in this manual to make this de- termination. (General purpose Central Offi
14、ce trunks are those used for answering incoming calls and are shared by administrative phones placing outside calls.) step 5. Step 6. Step 7. Step 8. Step 9. If the new system will have significantly more outgoing traffic than the previous system, increase the trunk requirements accordingly. If the
15、trunks are Centrex type and it will be necessary to make transfers within the Centrex system, special training will be required for using the built-in remote hook-flash signal of the TCIV or the TC4400 Console (refer to the In-Service Training and Remote Hook-Flash sec- tions of this manual). Determ
16、ine what wiring and station equipment from the original system will be usable in the TCIV. If the local Central Office does not provide tone dialing service, obtain a convertor for each trunk line. Convertors Required: Refer to the Ordering Checklist (following the Interconnect Layout Section) and e
17、nsure all hardware requirements are met. Interconnect Planning Survey of TCIV-PBX System Requirements Summary: Special considerations are required when planning systems which interface with a Central Office through a PBX. These include: the number and type of PBX lines which will interface with the
18、TCIV; TCIV feature restrictions which may result from the type of interlace; program- ming requirements; and, additional hardware to compensate for combined TCIV and PBX line losses. Other considerations include variations in transfer procedures and visual indications available to the PBX attendant
19、for transferring calls to TCIV stations. Step 1. step 2. Step 3. Determine the number of extensions required for people mainly involved in internal com- munications, paging, and other TCIV functions: Assign these extensions to the TCIV. TCIV extension8 Determine the number of extensions required for
20、 people who mostly communicate with the outside world: Assign these extensions to the PBX. PBX extensions To support traffic between the TCIV and PBX, determine the number of E however, the following limitations make this the least preferred type of interlace. The keep-alive process must be used by
21、PBXextensions to hold the TCIV until an off- hook TCIV extension enters the connection. When ringing is used to indicate the start and stop of a service request to the TCIV, a time the complete current rules will be in the current copy of the FCCs Rules. All of the pertinent rules must be followed.
22、The TC4171 (COA) should only be connected to a standard subscriber line via the proper coupler installed by the telephone company; it should never be connected to a party line or coin line. You must give the local telephone company: a. notice that you want to install an FCC-approved device to their
23、line (similar notice is required of a final disconnect). b. the registration number and the ringer equivalence, which are marked on the compli- ance label, and C. the connection required for the TC4171 (COA), the RJ21X, RJllC, or RJllW (see this manual, M-1582, the installation manual, IU-1583, and
24、wiring diagrams KM-0714 and KM-0716). Once the telephone company has installed the proper connector, insert the plug coming from the TC4171 wire-wrap terminals. No repairs may be made to the TC4171 (COA) or to the TC4001 (main central assembly) while the TC4171 is connected to the phone line. If any
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Iv Ki-1582-Interconnect Planning 电路图 Ki 1582 Interconnect
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220897.html



Marshall-9100-62-02-Schematic电路原理图.pdf