Rauland Telecenter V - Installation Drawings Ki-1695B 电路图.pdf
《Rauland Telecenter V - Installation Drawings Ki-1695B 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter V - Installation Drawings Ki-1695B 电路图.pdf(39页珍藏版)》请在收音机爱好者资料库上搜索。
1、Telecenter V Installation Drawings MI- 1695B RAULAND-BORG CORPORATION ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (847) 679-0900 System Assembly page 2 Installation Notes Central-System Wiring Diagrams TC4002 Main Wiring Diagram KM 1035 TC4196 Relay Signal Logic KM 1098 Room Station Wir
2、ing Diagrams Administrative Telephones . KM 1061 Speakers with Call-In Switches . KM 1062 Dialing Staff Telephone with Call-in Switches . KM 1063 Non-Dialing Staff Telephone with Call-in Switches . KM 1064 Central-System Accessory Wiring Diagrams TC4165 VCM (Voice-Controlled Module) Expander . KM 10
3、53 TC4222 VFD (Vacuum Fluorescent Display) Wiring . KM 1054 Master Clock . KM 1055 External Tone Activation . KM 1056 Manual Memory-Block Switch . KM 1057 TCV Connected to a Modem or a Computer . KM 1058 Cable Plan and Assignment Charts Uniform Cabling Plan KM1047 TCV Physical Number Layout Planning
4、 Worksheet KM 1102 TC4155 Block vs. Physical Number Assignment Chart KM 1048 TC4155 Cable Assignment Chart (LLMO) . KM 1049 TC4155 Cable Assignment Chart and Work Sheet (LLM#) KM 1050 TC41XX/CAM25 Block Assignment Chart KM 1103 TC41XX/CAM25 Cable Assignment Chart and Work Sheet (SC25#) KM 1052 01993
5、 RAULAND-BORG CORPORATION ? Printed in U.S.A. Page 1 of 39 Orig. 6/92. Rev. 12/92,9/93. 169502 RadioFans.CN 收音机爱 好者资料库 Telecenter V Installation Drawings Drawings List (can t) Wire Routing Diagrams TC4002 and TC4180 . MR200, PSX300, and TCS4560 . . . MCZ300, MCB300, MCT300, and MCC300 ., 2524 and 24
6、90 Master Clock, and MCXSOO Radio/Cassette Player . TCS4530 Remote Transmitter DAX 120 and DAXGO Amplifiers TCV Field-Wired Components . FAXGO, FAX120, and FAX250 Fire-Alarm Amplifiers Location of Equipment Mounted on the Inside Walls of a Telecenter Rack . IL0432 IL0433 IL0434 IL0435 IL0436 IL0437
7、IL0438 IL0439 IL0440 System Assembly The Telecenter V system may be shipped fully assem- bled or as component shelves. To ensure the stability of the rack and ease in wiring, the relative position of the chassis shelves must be as follows: shown. Specific connections between components are shown in
8、the main wiring diagram, KM1035. ? All audio amplifiers must be placed in the bottom of the rack. If there is more than one amplifier, the higher-power unit must be placed at the bottom of the rack. ? The TC4145 LLM chassis is typically placed directly below the TC4002, and the switch banks are typi
9、cally placed directly above the TC4002. This arrangement minimizes the length of flat-ribbon cable run to these chassis. ? The remaining units may be placed in any position in the rack. Fill the unused rack spaces with blank panels. Wiring Refer to the wire routing diagrams in this manual when wirin
10、g each unit. Be sure to route and secure all wires as Field wiring includes all cables which exit the Telecen- ter V rack. Refer to the field-wiring diagrams included in this manual. Route and secure all wires and cables as shown in these diagrams. In addition to the wiring diagrams, an equipment- m
11、ounting diagram (ILO440) is included in this manual. This shows the location of equipment mounted to the left and right inside walls of the rack. General Precautions ? Never wire a telephone during an electrical storm. ? Never install telephone jacks in wet locations unless the jack is specifically
12、designed for wet locations. ? Use caution when installing or modifying telephone lines. ? Never touch uninsulated telephone wires or termi- nals unless the telephone line has been discon- nected at the network interface. I I Page 2 9/93 RadioFans.CN 收音机爱 好者资料库 Telecenter V Installation Drawings Inst
13、allation Notes The drawings are listed in five groups: Central-System Wiring, Room-Station Wiring, Central-System Accessories Wiring, Cabling and Assignment Charts, shows accessories installation to the TC4002 main switch. These drawings represent the most commonly or requested applications using ex
14、ternal devices. Cable Plans and Assignments The Uniform Cabling plan provides a method of cross- connecting equipment wiring to field (or room) wiring that allows easy access to all terminations, thus simplifying cable identification and troubleshooting. Some installers may prefer using three sets o
15、f punch- down blocks (equipment blocks, field blocks, and cross- connection blocks). The main drawbacks to this method are that it requires three times the space and the extra expense of the additional blocks. Whichever method you use, number and label the blocks clearly and use of both sides of spl
16、it blocks. Remember that equipment wiring should be terminated on the left side, and field wiring on the right side (enter from the left and exit on the right). Following the Uniform Cabling Plan are Cable-Assign- ment Charts for both the TC4155 Line Link Modules (LLMs) and the TC4110 (X25) and TC41
17、20 (SCC25) relay boards (terminated with a CAM25 male cable assembly). Wire Routing Diagrams This group of diagrams shows the proper wiring for each unit, including the recommended location of cable ties. Maintenance for the CPU battery The battery in the CPU circuit card (part of the TC4002) must b
18、e replaced every five years. Use the following procedure when changing the battery: Step 1. Shut off the system using the switch on the back of the TC4002. Step 2. Remove the front panel cover of the TC4002 and the retaining bracket. Step 3. Remove the ribbon cable connected to the CPU assembly. Thi
19、s assembly is 6 inches wide and is located on the right side of the rack (as viewed from the front). It is labeled CPU. Step 4. Put a personal grounding strap around your wrist and attach it to the unit. Step 5. Now remove the CPU from the rack. Step 6. Remove the coin-shaped battery from the holder
20、 and replace it with a 3-VDC, 24rnm in diameter, 250 rnA.Hr capacity coin cell battery, positive side up. We recommend the use of Sanyo CR2430 or Duracell DL2430. Step 7. Replace the CPU board, retaining bracket, flat-rib- bon cable, and the front panel cover of the TC4002. Step 8. Turn the system o
21、n. Model List The following is a list of all Telecenter V units and accessories: 2524 Master Clock 2490 Master Clock 6400 24-vDC Power Supply DAXGO Audio Amplifiers DAX120 Audio Amplifiers FAX60 Audio Amplifiers FAX120 Audio Amplifiers FAX250 Audio Amplifiers MCB300 Program Control Panel MCC300 Inte
22、rcom Control Panel MCT300 Telephone Control Panel MCX300 Radio/Cassette Player MCZ300 Master Control Panel MRlOO Media Retrieval MR200 Media Retrieval Chassis PSX300 28-WC Power Supply RAc900 AC Power Strip or Equivalent RPllOO cabinet RPllOl cabinet RP1102 cabinet RP1103 cabinet 9/93 Page 3 Telecen
23、ter V Installation Drawings S662CF Connector Block SW25 Switch Banks SWT425 Switch Banks TC4002 Main Chassis TC4110 Switch Bank TC4120 Switch Bank TC4130 Switch Bank TC4131 Switch Bank TC4145 LLM32 Expansion Chassis TC4155 LLM32 TC4156 48 v Line Hybrids Tc4160 TC4180 TC4181 TC4182 TC4183 TC4190 TC42
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Installation Drawings Ki-1695B 电路图 Ki 1695
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-220922.html



Marshall-9100-62-02-Schematic电路原理图.pdf