1、TELECENTERTVj SYSTEM DESIGN GUIDE Before you complete the detailed Telecenter IV Order Form fill in the information below Distributor (your name and address):Installation For (customers name and address): Please provide the following data: Speaker only lines Speakers with call switches Speakers with
2、 Single Link Phones Speakers with Multi Link Phones Multi Link Phone on/y lines Administrative phone only lines Administrative phones with speakers Central office lines TC4160 Added Intercom Channels TC4110 or TC4120TC4120 Single Link Phone Circuits Quantities Number of TC411O/TC4120 to be assigned
3、to each Intercom Channel I.C. Channel-lI.C. Channel-2 I.C. Channel-4I.C. Channel-5 TC4150 Administrative or Multi Link Phone I.C. Channel-3 I.C. Channel-6 Any Special Requirements and/or Optional Equipment-Please list: IMPORTANT: 1. Use rack diagram sheet for panel layout design (attached) RadioFans
4、.CN 收音机爱 好者资料库 1 ORDER FORM / TELECENTER IV BASIC EQUIPMENT TC4001 TC4150 TC4140 TC4110 TC4120 TC4120 TC4130 MODEL NO. Central Control (one required in a system) Line Link Module (one required for each 16 Multi-Link Telephone Lines) QUANTITY 1 T- RACK SPACE Expander Chassis (holds up to five TC4150
5、Line-Link Modules) a.75 None mounts In TC4140 7.00 ea. Speaker Control Assembly (one required Mounts on for each 25 speaker line) switch panels Speaker Control Assembly Rack Mounted (one required for each 25 speaker lines) 1.75 ea. For Single Link Telephone Lines (one required for each 25 telephone
6、lines) TW25 Two Wire Adaptor cannot be used with Single Link Telephonesr Speaker Control Assembly with OFF Bus-Rack Mounted (one required for each 25 speaker lines) 1.75 ea. I I FOR ALL CALL ADD: UNIT PRICE TOTAL PRICE ,I II I Power Amplifier ( ) specify appropriate model for required power. If prog
7、ramming is provided Channel A amplifier is used for all All-Call. See Notes. Function of Amp. FOR DISTRIBUTION OF ALARM SIGNALS AND SINGLE CHANNEL TIME SIGNALS: MTG100 Tone Generator Moduleuses All Call amplifier FOR 8 AREA ZONE PAGING ADD: Power Amplifier ( ) specify appropriate model for required
8、power. See Notes. Function of Amp. NOTES: 1. 2. TOTAL The FD150 Amplifier cannot be used with Telecenter IV Systems. The CCA Series Amplifiers require factory modification when used with the Telecenter IV The modified amplifiers will be marked SPXCCA _ _ _ _ RadioFans.CN 收音机爱 好者资料库 TELEPHONE ACCESSO
9、RY EQUIPMENT ORDER FORM MODEL NO. QUANTITY RACK SPACE UNIT PRICE TOTAL PRICE TELEPHONES TC4202 Administrative Telephone Single-Line, less display with Tap Button TC4211 TC4250 TC4300 CRT3 Administrative Telephone Single-Line with display and Tap Button Administrative Telephone with 5 line key and di
10、splay. Used with key system. Administrative Telephone Single Line Remote (Staff) Telephone Desk or Wall Mount w/Ringer WALL DISPLAY Wall Display (Requires local AC 1”“” Power) None NOTE: Maximum of 6 Displays in a system, Mounts in including Display Telephones 5 Gang Box REMOTE SPEAKER STATIONS RS50
11、5 Universal Speaker Module. Used with P2307, PBS113, PCS113 and RS500 Series Switches None Mounts in 3 Gang Box DSS-1 Dormitory Station: Wall Type, Flush Mounted (Requires 28VDC power source) None Mounts in 2 Gang Box HIGH SECURITY INTERCOM STATIONS HSS1 Vandal Proof Station with Speaker and Call-in
12、 Switch None Mounts in 3 Gang Box HSS2 Vandal Proof Station with speaker only None Mounts in 3 Gang Box HSS3 Vandal Proof Call-in Switch Mounts in Single Gang Box TELEPHONE/ACCESSORY EQUIPMENT TOTAL Add this total to Telecenter IV Equipment Total ACCESSORY EQUIPMENT MODEL NO. QUANTITY UNIT PRICE TOT
13、AL PRICE CALL IN SWITCHES OS10A Three-Position, Spring Return From “Call” IIII 0S11A Two-Position, Spring Return From “Call” IIII 23028 2304FA P2307 Non-Locking Rotary Momentary Pushbutton Type Three-Position-Rocker-Spring Return I RS504 Door Entry Station: Three Buttons-Call, Talk Door I I I I RS50
14、6 RS507 PBS1 13 Pull Chain Switch: Momentary Type Push Button Switch: Momentary Type Push Button Bath Station with Remote Cancel. Requires 12 VDC. PCS1 13 Pull Chain Bath Station with Remote Cancel. Requires 12 DC. I I I I SPEAKERS-HORNS US0188 8” Speaker With Transformer (25V) IIII 1 49902-8CL 1 8”
15、 Speaker-Wall Baffle Assembly 3701 3702 3703 3601 15W Page/Talkback Horn 30W Page/Talkback Horn 30W Wide Ang. Page/Talkback Horn 15W Page/Talkback Horn 30W Page/Talkback Horn 3603 30W Wide Ang. Page/Talkback Horn IIII CLOCK SYSTEM ACCESSORIES See Separate Design Guide For Clock Systems TOTAL PAGE 3
16、TOTAL SYSTEM TOTAL With Accessories 1 ORDER FORM / TELECENTER IV EQUIPMENT(C.) MODEL NO. QUANTITY RACK SPACE FOR 8 CHANNEL TIME SIGNALS ADD: UNIT TOTAL PRICE PRICE MTG100 Tone Generator Module (not required if I Mounts in MTG1OO is orovided for Alarm Sianals). TC4001II Power Amplifier ( ). Specify a
17、ppropriate model for required power. Function NOTE: Only one amplifier is required for both of Amp Time Signals and Zone Paging. Selected FOR ADDITIONAL INTERCOM CHANNELS ADD: TC4160 Voice Controlled Amplifier Module. None mounts Each module must have its own assigned in TC4001(1) TC4110/TC4120 asse