1、RAULAND-BORG CORPORATION ? 3450 West Oakton Street, Skokie, Illinois 60076-2951 ? (708) 679-0900 PRELIMINARY DESCRIPTION The SW25 and SWL25 panels are used with all Direc- tor Series sound and communications systems. These panels let you selectively connect up to 25 rooms to either the program or th
2、e intercom channel. There is also a center OFF position. Color-coded directions identify each channel: green for program, and orange for intercom. The SW25 offers room selection only (no call-in signal). The SWL25 also provides a call-in signal. When a call is made from a switch in the classroom, an
3、 LED lights next to the corresponding number on the panel and a tone alerts the console operator to the call. The LED lamp remains lit until the operator answers the call, at which time the lamp automatically shuts off. INSTALLATION CABLING REQUIREMENTS RECOMMENDED TERMINATIONS Systems using the SW2
4、5 (no call-in signal) require one twisted pair in a shield for each speaker station. Systems using the SWL25 (call-in signal) require one additional conductor within the shielded cable for each speaker station. Use #22-AWG solid or stranded conductors with 22-AWG drain wire. If youre using insulatio
5、n-piercing connectors, the outside diameter of any wire, including its insulation, must not exceed 0.095”. Insulation-piercing connectors are the fastest, most reliable way to terminate wire to the switchbank. These connectors must be ordered separately. Order one SK- 2522 Connector Kit for each swi
6、tchbank. The kit contains 25 four-terminal connectors for 22-AWG wire. The at- tached manual, KI-1564, tells how to install these connec- tors. ALTERNATIVE METHOD #l CABLE ROUTING AND STRAIN RELIEF Route the cables as shown in the diagram. Secure them with three plastic cable ties through the guide
7、loops in the rear bracket. Leave service loops in the cables used to interconnect the equipment panels and at least a one-inch slack in each cable. This permits reconnection when re- quired. Modified wire wrapping may be used to terminate 22- or 24-AWG solid conductors. Strip back wire about 1%” and
8、 use a wire-wrapping tool that provides one complete turn of insulation around the terminal pm. This modified wire wrap provides the required strain relief. ALTERNATIVE METHOD #2 Connect the twisted pair to terminals D and E, and the drain wire to terminal G for each line circuit. On Model SWL25 onl
9、y, connect the third conductor for call-in to terminal T (Trigger). CONNECTOR OR BUS WIRING There are three terminals (OFF, A, C) at the ends of the switchbank that will be interconnected in a factory-wired system. These interconnections provide loop-through for common functions, especially between
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- Rauland Telecenter Iv Sw25 And Swl25 Room Selector Panels 电路图
收音机爱好者资料库所有资源均是用户自行上传分享,仅供网友学习交流,未经上传用户书面授权,请勿作他用。
链接地址:http://www.radiofans.cn/p-221048.html



Marshall-9100-62-02-Schematic电路原理图.pdf