Rauland Telecenter V - Ki-1692C-Programming 电路图.pdf
《Rauland Telecenter V - Ki-1692C-Programming 电路图.pdf》由会员分享,可在线阅读,更多相关《Rauland Telecenter V - Ki-1692C-Programming 电路图.pdf(53页珍藏版)》请在收音机爱好者资料库上搜索。
1、Programming KI-1692C Telecenter V Communications System Programming Rauland-Borg Corporation Issued: 06/25/98 Page 1 of 53 RadioFans.CN 收音机爱 好者资料库 Copyright 1998 by Rauland-Borg Corporation, all rights reserved. This document contains users information on technology that is proprietary to Rauland-Bo
2、rg Corporation. Permitted transmittal, receipt, or possession of this document does not express license or imply any rights to use, sell, design or manufacture this information. No reproduction, publication, or disclosure of this information, in whole or in part, shall be made without prior written
3、authorization from an officer of Rauland-Borg Corporation. Rauland-Borg Corporation Rauland-Borg Corporation 3450 West Oakton Street Skokie, Illinois 60076-2958 (847) 679-0900 RadioFans.CN 收音机爱 好者资料库 KI-1692C Telecenter V Communications SystemProgramming Table of Contents GENERAL INFORMATION. 4 DESC
4、RIPTION. 4 REVISION HISTORY. 4 PROGRAMMING OVERVIEW. 5 PREPARATIONS FOR PROGRAMMING. 6 CHANGES AVAILABLE FROM PHONES. 7 SETTING INDIVIDUAL LINES. 8 INITIAL CHOICES. 8 INDIVIDUAL LINES. 8 DEFINING CLASSES OF SERVICE.10 CLASS ATTRIBUTES.10 LOCATION CODES .14 SYSTEM SETTINGS.14 MEMORY ALLOCATIONS.14 IN
5、TERCEPT TABLE.15 OVERVIEW.15 INTERCEPT TABLE FORMAT.15 INTERCEPT ACTIONS.16 PRE-SEQUENCE STRING.17 APPENDIX A: LOCATION CODES.18 APPENDIX B: CLASS OF SERVICE TYPES other blocks could store programming for night or holiday operation. Basic systems may only use Block 1. The Telecenters Time-Based Memo
6、ry Event Manager provides an automatic method of controlling the memory block switching on a daily (time) basis. See the Location Code Directory and the Telecenter Diagnostic Disk manual (KI-1730) for more information. Individual Lines In the TD5 program, the Class of Service editor provides a metho
7、d to select line type and Attributes. Most line programming can be accomplished under the Attributes settings. Appendix B shows the complete Attributes that are available for each Class of Service type. Refer to this section when modifying or creating new Class of Service types. Architectural Number
8、 As explained in the Planning Manual, Physical Numbers represent the terminals where telephones, speakers, call-in switches, and other equipment can be wired to the system. These are internal numbers the system uses for its operations, such as connecting two lines to a link so they can communicate w
9、ith each other. The Architectural Number (so-called because floor and room numbers are commonly chosen) is the number that users will dial to reach a particular line. When choosing an Architectural Number, observe these rules: ? Give all Architectural Numbers in the system the same number of digits
10、(3 or 4, as set in Location 60). ? Do not use duplicate numbers. 2 KI-1692C Telecenter V Communications SystemProgramming Page 9 of 53 (06/25/98) Selection of a Class of Service Appendix D provides a chart of the Classes of Service set by the factory. Entering the number of the desired Class of Serv
11、ice (0-63) will usually meet most programming needs. ? Important: several of the default Classes of Service have identical programming. This allows installers to set up several Classes of Service with minor differences, by simply modifying one or two settings. Hunt Bit for Call-Handling Setting the
12、Hunt feature tells the system to route a call to the next-highest Physical Number when this line is busy. If the next line is busy, the system will continue hunting for a line that is not busy until it finds one that is available or it no longer finds an active hunt bit. On trunk lines (AAI, DIL, DI
13、SA), the Hunt feature applies only to outgoing calls; the central offices or other external systems hunt for incoming calls to the Telecenter system. The Hunt feature affects only calls from dialing phones. Call-ins, made by call switches and non-dialing phones (when their receivers are lifted off-h
14、ook), are controlled by the r settings for the Class of Service. The second Hunt setting is reserved for future use. Zones The Zones group stations with speakers so that the system can page or send tone signals to specified areas. Each station can be in any number and combination of zones, or in non
15、e. Under the Z: heading, enter the number of each zone desired, to select them or make them all blank. Programming Individual Lines Individual AttributesClass of Service(s) Attributes n: Architectural (dialing) Number A: Line Type (administrative, staff, media, etc.) s: Class of Service (enter the n
16、umber from 0 to 63 to set the desired Class of Service) B: Authorizations (outside calling, paging, etc.) H: Hunt (sent call to next line when this is busy) C: Interconnect Options Z: Assign Speaker Zonesr0-r3: Routing Call-ins For further details on Individual Attributes, see Setting Individual Lin
17、es. For detailed Class of Service setting descriptions, see Appendix B. KI-1692C Telecenter V Communications SystemProgramming Page 10 of 53 (06/25/98) Defining Classes of Service This section contains information on modifying or establishing Classes of Service. Most installations only require small
18、 modifications to the factory programmed Classes. Accordingly, you can pick a duplicate or unprogrammed Class of Service from the chart of the factory-default settings in Appendix D, then consult the detailed listings of the individual Classes of Service in Appendix B to plan alternate settings. Cla
19、ss Attributes The four types (A:, B:, C:, and r:) are described in the following subsections. A: Attributes (Line Type) A:1-4 Determine the general type of service the system will supply the line (a dialing phone, media-control line, trunk that directs calls to an attendant, etc.). A:7 Directs that
20、any call to this line be immediately connected to its associated speaker. If there is also a telephone, the user there has the option of switching communications to the phone by picking up its handset. Dialing # prior to the desired number will toggle the systems setting for that particular call. A: